34 resultados para Sample preservation
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
A sample of Pulmonata collected in Santa Maria da Vitória, interior of Bahia, Brazil, in Caatinga semi-arid environment, is studied taxonomically. From the five species, four are revealed as new, including a new genus. The new taxa are the Bulimulidae (1) Kora corallina gen. et sp. n. characterized by the elongated shell with aperture somewhat dislocated from the shell axis, and an oblique tooth in middle level of inner lip; (2) Spixia coltrorum, mainly characterized by an uneven spire, delicate sculpture and peristome with 4 equidistant teeth; (3) Anostoma tessa, mainly characterized by a broad spire and well-developed anal canal; and the Megalobulimidae (4) Megalobulimus amandus, mainly characterized by pointed protoconch sculptured by dense quantity of axial cords. Rhinus suturalis is the only previously known species, but its geographic distribution is expanded southwards to Bahia state. A discussion with respect to necessity for improving the study on the malacofauna from the interior region of the Brazilian Northeast and the importance for preservation of the Caatinga biome is also provided.
Resumo:
Most museums, libraries, and archives throughout the world have to deal with paper damaged by iron gall ink. For more than a decade international research has been devoted to the topic in an attempt to provide practical treatments for objects and formulate guidelines for the preservation of iron gall ink collections. A working group of conservators in South and Central America and the Caribbean have developed a program to disseminate research findings, collect data about the condition of iron gall ink collections in their countries and identify imminent training needs. The goal of this project is to combine the latest research with existing and acceptable conservation practices and share information about risk management, proper housing, examination and treatment of iron gall ink inscribed artefacts-at risk. Communications among colleagues were established to learn more about the current resources available in collections from various countries.
Resumo:
The purpose of this study was to examine the reliability, validity and classification accuracy of the South Oaks Gambling Screen (SOGS) in a sample of the Brazilian population. Participants in this study were drawn from three sources: 71 men and women from the general population interviewed at a metropolitan train station; 116 men and women encountered at a bingo venue; and 54 men and women undergoing treatment for gambling. The SOGS and a DSM-IV-based instrument were applied by trained researchers. The internal consistency of the SOGS was 0.75 according to the Cronbach`s alpha model, and construct validity was good. A significant difference among groups was demonstrated by ANOVA (F ((2.238)) = 221.3, P < 0.001). The SOGS items and DSM-IV symptoms were highly correlated (r = 0.854, P < 0.01). The SOGS also presented satisfactory psychometric properties: sensitivity (100), specificity (74.7), positive predictive rate (60.7), negative predictive rate (100) and misclassification rate (0.18). However, a cut-off score of eight improved classification accuracy and reduced the rate of false positives: sensitivity (95.4), specificity (89.8), positive predictive rate (78.5), negative predictive rate (98) and misclassification rate (0.09). Thus, the SOGS was found to be reliable and valid in the Brazilian population.
Resumo:
Background: Studies on functional capacity in community-dwelling older people have shown associations between declines in instrumental activities of daily living (IADL) and several factors. Among these, age has been the most consistently related to functional capacity independent of other variables. We aimed at evaluating the performance of a sample of healthy and cognitively intact Brazilian older people on activities of daily living and to analyze its relation to social-demographic variables. Methods: We conducted a secondary analysis of data collected for previous epidemiological studies with community-dwelling subjects aged 60 years or more. We selected subjects who did not have dementia or depression, and with no history of neurological diseases, heart attack, HIV, hepatitis or arthritis (n = 1,111). Functional capacity was assessed using the Brazilian version of the Older American Resources and Services Questionnaire (BOMFAQ). ADL performance was analyzed according to age, gender, education, and marital status (Pearson's chi(2), logistic regression). Results: IADL difficulties were present in our sample, especially in subjects aged 80 years or more, with lower levels of education, or widowed. The logistic regression analysis results indicated that "higher age" and "lower education" (p <= 0.001) remained significantly associated with IADL difficulty. Conclusions: Functional decline was present in older subjects even in the absence of medical conditions and cognitive impairment. Clinicians and researchers could benefit from knowing what to expect from older people regarding IADL performance in the absence of medical conditions.
Resumo:
A thin-layer electrochemical flow cell coupled to capillary electrophoresis with contactless conductivity detection (EC-CE-(CD)-D-4) was applied for the first time to the derivatization and quantification of neutral species using aliphatic alcohols as model compounds. The simultaneous electrooxidation of four alcohols (ethanol, 1-propanol, 1-butanol, and 1-pentanol) to the corresponding carboxylates was carried out on a platinum working electrode in acid medium. The derivatization step required 1 min at 1.6 V vs. Ag/AgCl under stopped flow conditions, which was preceded by a 10 s activation at 0 V. The solution close to the electrode surface was then hydrodynamically injected into the capillary, and a 2.5 min electrophoretic separation was carried out. The fully automated flow system operated at a frequency of 12 analyses per hour. Simultaneous determination of the four alcohols presented detection limits of about 5 x 10(-5) mol As a practical application with a complex matrix, ethanol concentrations were determined in diluted pale lager beer and in nonalcoholic beer. No statistically significant difference was observed between the EC-CE-(CD)-D-4 and gas chromatography with flame ionization detection (GC-FID) results for these samples. The derivatization efficiency remained constant over several hours of continuous operation with lager beer samples (n = 40).
Resumo:
PURPOSE: To evaluate the nutritional status of patients in the late postoperative period of pancreaticoduodenectomy (PD) and compare the long-term outcome according to pylorus-preserving (PPPD) or the standard technique (SPD) in which the pylorus is resected. METHODS: This prospective study was conducted twelve months prior or more in patients who had underwent PD (PD Group, n=15) and health volunteers (Control Group, n=15). At a post hoc analysis, the PD Group was divided in PPPD Subgroup (n=9) and SPD Subgroup (n=6), according to the PD techniques. Gastrointestinal complaints and nutritional status were evaluated, apart from a biochemical assessment; Student t-test or Mann-Whitney test were used. RESULTS: The patients recovered their body weight and the gastrointestinal complaints were uncommon. The PD Group showed higher energy and protein intake even though BMI was lower than in Control Group. There were no differences in laboratorial data, except for higher glycemia, serum alkaline phosfatase and C-reactive protein in PD Group. There was no difference in the various parameters evaluated when the Subgroups (PPPD and SPD) were compared. CONCLUSION: For long-term pancreaticoduodenectomy, the gastrointestinal symptoms are minimal and the patients had the clinical and nutritional status preserved, regardless of pylorus preservation.
Resumo:
OBJECTIVE: This study evaluated the performance of lungs that were preserved with different solutions (Celsior, Perfadex or saline) in an ex vivo rat lung perfusion system. METHODS: Sixty Wistar rats were anesthetized, anticoagulated and randomized into three groups (n = 20). The rats were subjected to antegrade perfusion via the pulmonary artery with Perfadex, Celsior, or saline, followed by 6 or 12 hours of ischemia (4 degrees C, n = 10 in each group). Respiratory mechanics, gas exchange and hemodynamics were measured at 10-minute intervals during the reperfusion of heart-lung blocks in an ex vivo system (IL2-Isolated Perfused Rat or Guinea Pig Lung System, Harvard Apparatus, Holliston, Massachusetts, USA; Hugo Sachs Elektronik, Germany) for 60 minutes. The lungs were prepared for histopathology and evaluated for edema following reperfusion. Group comparisons were performed using ANOVA and the Kruskal-Wallis test with a 5% level of significance. RESULTS: Gas exchange was not significantly different between lungs perfused with either Perfadex or Celsior at the same ischemic times, but it was very low in lungs that were preserved with saline. Airway resistance was greater in the lungs that were preserved for 12 hours. Celsior lungs that were preserved for 6 and 12 hours exhibited lower airway resistance (p = 0.01) compared to Perfadex lungs. Pulmonary artery pressure was not different between the groups, and no significant differences in histopathology and apoptosis were observed between the groups. CONCLUSIONS: Lungs that were preserved with Celsior or Perfadex exhibited similar gas exchange and histopathological findings. Airway resistance was slightly lower in the Celsior-preserved lungs compared with the Perfadex-preserved lungs.
Resumo:
Purpose: To evaluate endothelial cell sample size and statistical error in corneal specular microscopy (CSM) examinations. Methods: One hundred twenty examinations were conducted with 4 types of corneal specular microscopes: 30 with each BioOptics, CSO, Konan, and Topcon corneal specular microscopes. All endothelial image data were analyzed by respective instrument software and also by the Cells Analyzer software with a method developed in our lab(US Patent). A reliability degree (RD) of 95% and a relative error (RE) of 0.05 were used as cut-off values to analyze images of the counted endothelial cells called samples. The sample size mean was the number of cells evaluated on the images obtained with each device. Only examinations with RE<0.05 were considered statistically correct and suitable for comparisons with future examinations. The Cells Analyzer software was used to calculate the RE and customized sample size for all examinations. Results: Bio-Optics: sample size, 97 +/- 22 cells; RE, 6.52 +/- 0.86; only 10% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 162 +/- 34 cells. CSO: sample size, 110 +/- 20 cells; RE, 5.98 +/- 0.98; only 16.6% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 157 +/- 45 cells. Konan: sample size, 80 +/- 27 cells; RE, 10.6 +/- 3.67; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 336 +/- 131 cells. Topcon: sample size, 87 +/- 17 cells; RE, 10.1 +/- 2.52; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 382 +/- 159 cells. Conclusions: A very high number of CSM examinations had sample errors based on Cells Analyzer software. The endothelial sample size (examinations) needs to include more cells to be reliable and reproducible. The Cells Analyzer tutorial routine will be useful for CSM examination reliability and reproducibility.
Resumo:
Long-term sample storage can affect the intensity of the hybridization signals provided by molecular diagnostic methods that use chemiluminescent detection. The aim of this study was to evaluate the effect of different storage times on the hybridization signals of 13 bacterial species detected by the Checkerboard DNA-DNA hybridization method using whole-genomic DNA probes. Ninety-six subgingival biofilm samples were collected from 36 healthy subjects, and the intensity of hybridization signals was evaluated at 4 different time periods: (1) immediately after collecting (n = 24) and (2) after storage at -20 degrees C for 6 months (n = 24), (3) for 12 months (n = 24), and (4) for 24 months (n = 24). The intensity of hybridization signals obtained from groups 1 and 2 were significantly higher than in the other groups (p < 0.001). No differences were found between groups 1 and 2 (p > 0.05). The Checkerboard DNA-DNA hybridization method was suitable to detect hybridization signals from all groups evaluated, and the intensity of signals decreased significantly after long periods of sample storage.
Resumo:
Schizophrenia is a severe psychiatric disorder with frequent recurrent psychotic relapses and progressive functional impairment. It results from a poorly understood gene-environment interaction. The gene encoding catechol-O-methyltransferase (COMT) is a likely candidate for schizophrenia. Its rs165599 (A/G) polymorphism has been shown to be associated with alteration of COMT gene expression. Therefore, the present study aimed to investigate a possible association between schizophrenia and this polymorphism. The distribution of the alleles and genotypes of this polymorphism was investigated in a Brazilian sample of 245 patients and 834 controls. The genotypic frequencies were in Hardy-Weinberg equilibrium and no statistically significant differences were found between cases and controls when analyzed according to gender or schizophrenia subtypes. There was also no difference in homozygosis between cases and controls. Thus, in the sample studied, there was no evidence of any association between schizophrenia and rs165599 (A/G) polymorphism in the non-coding region 3' of the COMT gene.
Resumo:
Complexity in time series is an intriguing feature of living dynamical systems, with potential use for identification of system state. Although various methods have been proposed for measuring physiologic complexity, uncorrelated time series are often assigned high values of complexity, errouneously classifying them as a complex physiological signals. Here, we propose and discuss a method for complex system analysis based on generalized statistical formalism and surrogate time series. Sample entropy (SampEn) was rewritten inspired in Tsallis generalized entropy, as function of q parameter (qSampEn). qSDiff curves were calculated, which consist of differences between original and surrogate series qSampEn. We evaluated qSDiff for 125 real heart rate variability (HRV) dynamics, divided into groups of 70 healthy, 44 congestive heart failure (CHF), and 11 atrial fibrillation (AF) subjects, and for simulated series of stochastic and chaotic process. The evaluations showed that, for nonperiodic signals, qSDiff curves have a maximum point (qSDiff(max)) for q not equal 1. Values of q where the maximum point occurs and where qSDiff is zero were also evaluated. Only qSDiff(max) values were capable of distinguish HRV groups (p-values 5.10 x 10(-3); 1.11 x 10(-7), and 5.50 x 10(-7) for healthy vs. CHF, healthy vs. AF, and CHF vs. AF, respectively), consistently with the concept of physiologic complexity, and suggests a potential use for chaotic system analysis. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4758815]
Resumo:
Background: The Beck Depression Inventory (BDI) is used worldwide for detecting depressive symptoms. This questionnaire has been revised (1996) to match the DSM-IV criteria for a major depressive episode. We assessed the reliability and the validity of the Brazilian Portuguese version of the BDI-II for non-clinical adults. Methods: The questionnaire was applied to 60 college students on two occasions. Afterwards, 182 community-dwelling adults completed the BDI-II, the Self-Report Questionnaire, and the K10 Scale. Trained psychiatrists performed face-to-face interviews with the respondents using the Structured Clinical Interview (SCID-I), the Montgomery-angstrom sberg Depression Scale, and the Hamilton Anxiety Scale. Descriptive analysis, signal detection analysis (Receiver Operating Characteristics), correlation analysis, and discriminant function analysis were performed to investigate the psychometric properties of the BDI-II. Results: The intraclass correlation coefficient of the BDI-II was 0.89, and the Cronbach's alpha coefficient of internal consistency was 0.93. Taking the SCID as the gold standard, the cut-off point of 10/11 was the best threshold for detecting depression, yielding a sensitivity of 70% and a specificity of 87%. The concurrent validity (a correlation of 0.63-0.93 with scales applied simultaneously) and the predictive ability of the severity level (over 65% correct classification) were acceptable. Conclusion: The BDI-II is reliable and valid for measuring depressive symptomatology among Portuguese-speaking Brazilian non-clinical populations.
Resumo:
OBJECTIVE: To investigate drinking patterns and gender differences in alcohol-related problems in a Brazilian population, with an emphasis on the frequency of heavy drinking. METHODS: A cross-sectional study was conducted with a probability adult household sample (n = 1,464) in the city of Sao Paulo, Brazil. Alcohol intake and ICD-10 psychopathology diagnoses were assessed with the Composite International Diagnostic Interview 1.1. The analyses focused on the prevalence and determinants of 12-month non-heavy drinking, heavy episodic drinking (4-5 drinks per occasion), and heavy and frequent drinking (heavy drinking at least 3 times/week), as well as associated alcohol-related problems according to drinking patterns and gender. RESULTS: Nearly 22% (32.4% women, 8.7% men) of the subjects were lifetime abstainers, 60.3% were non-heavy drinkers, and 17.5% reported heavy drinking in a 12-month period (26.3% men, 10.9% women). Subjects with the highest frequency of heavy drinking reported the most problems. Among subjects who did not engage in heavy drinking, men reported more problems than did women. A gender convergence in the amount of problems was observed when considering heavy drinking patterns. Heavy and frequent drinkers were twice as likely as abstainers to present lifetime depressive disorders. Lifetime nicotine dependence was associated with all drinking patterns. Heavy and frequent drinking was not restricted to young ages. CONCLUSIONS: Heavy and frequent episodic drinking was strongly associated with problems in a community sample from the largest city in Latin America. Prevention policies should target this drinking pattern, independent of age or gender. These findings warrant continued research on risky drinking behavior, particularly among persistent heavy drinkers at the non-dependent level.
Resumo:
OBJECTIVE: Experimental studies on lung preservation have always been performed using animal models. We present ex vivo lung perfusion as a new model for the study of lung preservation. Using human lungs instead of animal models may bring the results of experimental studies closer to what could be expected in clinical practice. METHOD: Brain-dead donors whose lungs had been declined by transplantation teams were used. The cases were randomized into two groups. In Group 1, Perfadex (R) was used for pulmonary preservation, and in Group 2, LPDnac, a solution manufactured in Brazil, was used. An ex vivo lung perfusion system was used, and the lungs were ventilated and perfused after 10 hours of cold ischemia. The extent of ischemic-reperfusion injury was measured using functional and histological parameters. RESULTS: After reperfusion, the mean oxygenation capacity was 405.3 mmHg in Group 1 and 406.0 mmHg in Group 2 (p=0.98). The mean pulmonary vascular resistance values were 697.6 and 378.3 dyn.s.cm(-5), respectively (p=0.035). The mean pulmonary compliance was 46.8 cm H2O in Group 1 and 49.3 ml/cm H2O in Group 2 (p=0.816). The mean wet/dry weight ratios were 2.06 and 2.02, respectively (p=0.87). The mean Lung Injury Scores for the biopsy performed after reperfusion were 4.37 and 4.37 in Groups 1 and 2, respectively (p=1.0), and the apoptotic cell counts were 118.75/mm(2) and 137.50/mm(2), respectively (p=0.71). CONCLUSION: The locally produced preservation solution proved to be as good as Perfadex (R). The clinical use of LPDnac may reduce costs in our centers. Therefore, it is important to develop new models to study lung preservation.
Resumo:
We present a study of the stellar parameters and iron abundances of 18 giant stars in six open clusters. The analysis was based on high-resolution and high-S/N spectra obtained with the UVES spectrograph (VLT-UT2). The results complement our previous study where 13 clusters were already analyzed. The total sample of 18 clusters is part of a program to search for planets around giant stars. The results show that the 18 clusters cover a metallicity range between -0.23 and +0.23 dex. Together with the derivation of the stellar masses, these metallicities will allow the metallicity and mass effects to be disentangled when analyzing the frequency of planets as a function of these stellar parameters.