16 resultados para Pin on disc tests

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reduction of friction and wear in systems presenting metal-to-metal contacts, as in several mechanical components, represents a traditional challenge in tribology. In this context, this work presents a computational study based on the linear Archard's wear law and finite element modeling (FEM), in order to analyze unlubricated sliding wear observed in typical pin on disc tests. Such modeling was developed using finite element software Abaqus® with 3-D deformable geometries and elastic–plastic material behavior for the contact surfaces. Archard's wear model was implemented into a FORTRAN user subroutine (UMESHMOTION) in order to describe sliding wear. Modeling of debris and oxide formation mechanisms was taken into account by the use of a global wear coefficient obtained from experimental measurements. Such implementation considers an incremental computation for surface wear based on the nodal displacements by means of adaptive mesh tools that rearrange local nodal positions. In this way, the worn track was obtained and new surface profile is integrated for mass loss assessments. This work also presents experimental pin on disc tests with AISI 4140 pins on rotating AISI H13 discs with normal loads of 10, 35, 70 and 140 N, which represent, respectively, mild, transition and severe wear regimes, at sliding speed of 0.1 m/s. Numerical and experimental results were compared in terms of wear rate and friction coefficient. Furthermore, in the numerical simulation the stress field distribution and changes in the surface profile across the worn track of the disc were analyzed. The applied numerical formulation has shown to be more appropriate to predict mild wear regime than severe regime, especially due to the shorter running-in period observed in lower loads that characterizes this kind of regime.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate whether there are visual and neurophysical decrements in workers with low exposure to Hg vapor. Methods: Visual fields, contrast sensitivity, color vision, and neuropsychological functions were measured in 10 workers (32.5 +/- 8.5 years) chronically exposed to Hg vapor (4.3 +/- 2.8 years; urinary Hg concentration 22.3 +/- 9.3 mu g/g creatinine). Results: For the worst eyes, we found altered visual field thresholds, lower contrast sensitivity, and color discrimination compared with controls (P < 0.05). There were no significant differences between Hg-exposed subjects and controls on. neuropsychological tests. Nevertheless, duration of exposure was statistically correlated to verbal memory and depression scores. Conclusions: Chronic exposure to Hg vapor at currently accepted safety levels was found to be associated with visual losses but not with neuropsychological dysfunctions in the sample of workers studied. (J Occup Environ Med. 2009,51:1403-1412)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present the first numerical implementation of the minimal Landau background gauge for Yang-Mills theory on the lattice. Our approach is a simple generalization of the usual minimal Landau gauge and is formulated for the general SU(N) gauge group. We also report on preliminary tests of the method in the four-dimensional SU(2) case, using different background fields. Our tests show that the convergence of the numerical minimization process is comparable to the case of a null background. The uniqueness of the minimizing functional employed is briefly discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we discuss the effects of catalyst load with respect to carbon powder for several Pt and Pb-based catalysts, using formic acid as a model molecule. The discussion is based on electrochemical tests, a complete morphological investigation and theoretical calculations. We show that the Pt and Pb-based catalysts presented activity in formic acid oxidation at very low catalyst loads (e.g., 0.5% in respect to the carbon content). Physical characterisations demonstrate that the electrodes are composed of separated phases of Pt and lead distributed in Pt nanometric-sized islands that are heterogeneously dispersed on the carbon support and Pb ultra-small particles homogeneously distributed throughout the entire carbon surface, as demonstrated by the microscopy studies. At high catalyst loads, very large clusters of Pb(x)O(y) could be observed. Electrochemical tests indicated an increase in the apparent resistance of the system (by a factor of 19.7 Omega) when the catalyst load was increased. The effect of lead in the materials was also studied by theoretical calculations (OFT). The main conclusion is that the presence of Pb atoms in the catalyst can improve the adsorption of formic acid in the catalytic system compared with a pure Pt-based catalyst. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: Evaluation of the antimicrobial effect of skin disinfection techniques is essential to avoid the transmission of infectious agents during blood transfusion. The aim of this study was to examine the effectiveness of two methods of arm skin disinfection used in blood donors at a Hemotherapy Center in Brazil that represents an important centre for distributing haemocomponents to many cities in the country. Methods: Two skin disinfection techniques in 50 blood donors were evaluated. For the first arm, 10% povidone-iodine/two-stage technique was used. On the opposite arm, 0.5% chlorhexidine digluconate alcohol solution/one-stage technique was used. The swabs were seeded on three culture media: blood agar, mannitol salt agar and Mac Conkey agar. Automated bacterial classification based on biochemical tests/specific substrates was performed. Donor characteristics were collected using the computerised system of the Hemotherapy Center. Results: We found that microbial reduction was significantly higher for 10% povidone-iodine technique (98.57-98.87%) when compared with 0.5% chlorhexidine technique (94.38-95.06%). The species Leuconostoc mesenteroides and Staphylococcus hominis showed resistance to both disinfection techniques. We did not find statistically significant relationships between donor characteristics and microbial reduction. Conclusions: Arm skin disinfection with 10% povidone-iodine produced better antimicrobial activity. We must acknowledge that 10% povidone-iodine technique has the limitation of being a two-stage method. However, prevention of adverse events due to bacterial contamination and transfusion reactions should be prioritised. Production of hypoallergenic and stronger antiseptics that allowed a safe one-stage disinfection technique should be encouraged in health systems, not only in Brazil but also around the world.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a ball-on-disc wear test, an alumina ceramic body sliding against a silicon nitride ceramic body in water achieved an ultra-low friction coefficient (ULFC) of 0.004. The profilometer and EDX measurements indicated that the ULFC regime in this unmated Al2O3-Si3N4 pair was achieved because of the formation of a flat and smooth interface of nanometric roughness, which favored the hydrodynamic lubrication. The triboreactions formed silicon and aluminum hydroxides which contributed to decrease roughness and shear stress at the contact interface. This behavior enables the development of low energy loss water-based tribological systems using oxide ceramics. 13 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study design: Cross-sectional. Objective: To analyze the relationships between functional tests, arm strength and root mean square of surface electromyography (EMG). Setting: Sao Paulo, Brazil. Methods: Twenty-four individuals with chronic tetraplegia participated. Upper extremity motor score (UEMS), functional independence measure (FIM) motor score, spinal cord independence measure III and capabilities of upper extremity (CUE) were performed. Muscle strength of the right elbow flexors-extensors was assessed using dynamometry and manual muscle test (MMT) and EMG of right biceps and triceps brachii were performed. Spearman's rank correlation coefficients and Mann-Whitney's U-test were used. Results: Functional tests and UEMS correlated strongly among them. UEMS highly correlated with triceps dynamometry and EMG. The dynamometry showed a very high correlation with MMT on the extensor group and a moderate correlation with flexor group. Triceps EMG showed moderate correlation with FIM and CUE. High correlations between triceps EMG and elbow extensors dynamometry and MMT were observed. A significant better performance on functional tests was observed on lower ASIA motor levels. The low-tetraplegia group showed a significant higher score on triceps EMG and dynamometry. Conclusion: Arm strength and EMG seem to be related to functional capabilities and independence in chronic tetraplegia. Spinal Cord (2012) 50, 28-32; doi:10.1038/sc.2011.95; published online 30 August 2011

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background Identification of nontuberculous mycobacteria (NTM) based on phenotypic tests is time-consuming, labor-intensive, expensive and often provides erroneous or inconclusive results. In the molecular method referred to as PRA-hsp65, a fragment of the hsp65 gene is amplified by PCR and then analyzed by restriction digest; this rapid approach offers the promise of accurate, cost-effective species identification. The aim of this study was to determine whether species identification of NTM using PRA-hsp65 is sufficiently reliable to serve as the routine methodology in a reference laboratory. Results A total of 434 NTM isolates were obtained from 5019 cultures submitted to the Institute Adolpho Lutz, Sao Paulo Brazil, between January 2000 and January 2001. Species identification was performed for all isolates using conventional phenotypic methods and PRA-hsp65. For isolates for which these methods gave discordant results, definitive species identification was obtained by sequencing a 441 bp fragment of hsp65. Phenotypic evaluation and PRA-hsp65 were concordant for 321 (74%) isolates. These assignments were presumed to be correct. For the remaining 113 discordant isolates, definitive identification was based on sequencing a 441 bp fragment of hsp65. PRA-hsp65 identified 30 isolates with hsp65 alleles representing 13 previously unreported PRA-hsp65 patterns. Overall, species identification by PRA-hsp65 was significantly more accurate than by phenotype methods (392 (90.3%) vs. 338 (77.9%), respectively; p < .0001, Fisher's test). Among the 333 isolates representing the most common pathogenic species, PRA-hsp65 provided an incorrect result for only 1.2%. Conclusion PRA-hsp65 is a rapid and highly reliable method and deserves consideration by any clinical microbiology laboratory charged with performing species identification of NTM.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the diagnosis of Graves' orbitopathy is primarily made clinically based on laboratory tests indicative of thyroid dysfunction and autoimmunity, imaging studies, such as computed tomography, magnetic resonance imaging, ultrasound and color Doppler imaging, play an important role both in the diagnosis and follow-up after clinical or surgical treatment of the disease. Imaging studies can be used to evaluate morphological abnormalities of the orbital structures during the diagnostic workup when a differential diagnosis versus other orbital diseases is needed. Imaging may also be useful to distinguish the inflammatory early stage from the inactive stage of the disease. Finally, imaging studies can be of great help in identifying patients prone to develop dysthyroid optic neuropathy and therefore enabling the timely diagnosis and treatment of the condition, avoiding permanent visual loss. In this paper, we review the imaging modalities that aid in the diagnosis and management of Graves' orbitopathy, with special emphasis on the diagnosis of optic nerve dysfunction in this condition.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper examines the local power of the likelihood ratio, Wald, score and gradient tests under the presence of a scalar parameter, phi say, that is orthogonal to the remaining parameters. We show that some of the coefficients that define the local powers remain unchanged regardless of whether phi is known or needs to be estimated, where as the others can be written as the sum of two terms, the first of which being the corresponding term obtained as if phi were known, and the second, an additional term yielded by the fact that phi is unknown. The contribution of each set of parameters on the local powers of the tests can then be examined. Various implications of our main result are stated and discussed. Several examples are presented for illustrative purposes

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The symptoms of lumbar disc herniation, such as low back pain and sciatica, have been associated with local release of cytokines following the inflammatory process induced by the contact of the nucleus pulposus (NP) with the spinal nerve. Using an animal experimental model of intervertebral disc herniation and behavioral tests to evaluate mechanical (electronic von Frey test) and thermal (Hargreaves Plantar test) hyperalgesia in the hind paw of rats submitted to the surgical model, this study aimed to detect in normal intervertebral disc the cytokines known to be involved in the mechanisms of inflammatory hyperalgesia, to observe if previous exposure of the intervertebral disc tissue to specific antibodies could affect the pain behavior (mechanical and thermal hyperalgesia) induced by the NP, and to observe the influence of the time of contact of the NP with the fifth lumbar dorsal root ganglion (L5-DRG) in the mechanical and thermal hyperalgesia. The cytokines present at highest concentrations in the rat NP were TNF-alpha, IL-1 beta and CINC-1. Rats submitted to the disc herniation experimental model, in which a NP from the sacrococcygeal region is deposited over the right L5-DRG, showed increased mechanical and thermal hyperalgesia that lasted at least 7 weeks. When the autologous NP was treated with antibodies against the three cytokines found at highest concentrations in the NP (TNF-alpha, IL-1 beta and CINC-1), there was decrease in both mechanical and thermal hyperalgesia in different time points, suggesting that each cytokine may be important for the hyperalgesia in different steps of the inflammatory process. The surgical remotion of the NP from herniated rats 1 week after the implantation reduced the hyperalgesia to the level similar to the control group. This reduction in the hyperalgesia was also observed in the group that had the NP removed 3 weeks after the implantation, although the intensity of the hyperalgesia did not decreased totally. The removal of the NP after 5 weeks did not changed the hyperalgesia observed in the hind paw, which suggests that the longer the contact of the NP with the DRG, the greater is the possibility of development of chronic pain. Together our results indicate that specific cytokines released during the inflammatory process induced by the herniated intervertebral disc play fundamental role in the development of the two modalities of hyperalgesia (mechanical and thermal) and that the maintenance of this inflammation may be the most important point for the chronification of the pain.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE. We previously demonstrated that most eyes have regionally variable extensions of Bruch's membrane (BM) inside the clinically identified disc margin (DM) that are clinically and photographically invisible. We studied the impact of these findings on DM- and BM opening (BMO)-derived neuroretinal rim parameters. METHODS. Disc stereo-photography and spectral domain optical coherence tomography (SD-OCT, 24 radial B-scans centered on the optic nerve head) were performed on 30 glaucoma patients and 10 age-matched controls. Photographs were colocalized to SD-OCT data such that the DM and BMO could be visualized in each B-scan. Three parameters were computed: (1) DM-horizontal rim width (HRW), the distance between the DM and internal limiting membrane (ILM) along the DM reference plane; (2) BMO-HRW, the distance between BMO and ILM along the BMO reference plane; and (3) BMO-minimum rim width (MRW), the minimum distance between BMO and ILM. Rank-order correlations of sectors ranked by rim width and spatial concordance measured as angular distances between equivalently ranked sectors were derived. RESULTS. The average DM position was external to BMO in all quadrants, except inferotemporally. There were significant sectoral differences among all three rim parameters. DM- HRW and BMO-HRW sector ranks were better correlated (median rho = 0.84) than DM- HRW and BMO-MRW (median rho = 0.55), or BMO-HRW and BMO-MRW (median rho = 0.60) ranks. Sectors with the narrowest BMO-MRW were infrequently the same as those with the narrowest DM-HRW or BMO-HRW. CONCLUSIONS. BMO-MRW quantifies the neuroretinal rim from a true anatomical outer border and accounts for its variable trajectory at the point of measurement. (Invest Ophthalmol Vis Sci. 2012;53:1852-1860) DOI:10.1167/iovs.11-9309

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The deformation of a ring under axial compression is analyzed in order to estimate a favorable ring specimen geometry capable of limiting the influence of friction on the stress-strain curve obtained from SHPB tests. The analysis shows that the use of a ring specimen with a large inner diameter and a small radial thickness offers some advantages comparing with the traditional disk sample. In particular, it can improve the reliability of the test results for ductile materials in the presence of friction. Based on the deformation analysis of a ductile ring under compression, a correction coefficient is proposed to relate the actual material stress strain curve with the reading from the SHPB. It is shown using finite element simulation that the proposed correction can be used for a wide range of conventional ductile materials. Experimental results with steel alloys indicate that the correction procedure is an effective technique for an accurate measurement of the dynamic material strength response. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The current cosmological dark sector (dark matter plus dark energy) is challenging our comprehension about the physical processes taking place in the Universe. Recently, some authors tried to falsify the basic underlying assumptions of such dark matterdark energy paradigm. In this Letter, we show that oversimplifications of the measurement process may produce false positives to any consistency test based on the globally homogeneous and isotropic ? cold dark matter (?CDM) model and its expansion history based on distance measurements. In particular, when local inhomogeneity effects due to clumped matter or voids are taken into account, an apparent violation of the basic assumptions (Copernican Principle) seems to be present. Conversely, the amplitude of the deviations also probes the degree of reliability underlying the phenomenological DyerRoeder procedure by confronting its predictions with the accuracy of the weak lensing approach. Finally, a new method is devised to reconstruct the effects of the inhomogeneities in a ?CDM model, and some suggestions of how to distinguish between clumpiness (or void) effects from different cosmologies are discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the swelling behaviour of clayey materials under controlled suction imposed both by a Richards chamber and by controlling the relative humidity with concentrated saline solutions. Soil-water characteristic curves (matrix and total) were determined by the filter paper method. The materials under study belong to the Guabirotuba Formation, of Pleistocene age, in the Curitiba Basin in the state of Parana, southern Brazil. Materials under several stages of suction of 5000-40 000 kPa were subjected to swelling tests in an oedometer press. The results indicated that the greater the suction the higher the swelling pressure. However, when swelling tests were carried out with suction variation controlled by relative humidity, in which the increase in moisture was very slow, the samples showed no swelling.