2 resultados para Official Plan Evaluation

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Moreira, A, McGuigan, MR, Arruda, AFS, Freitas, CG, and Aoki, MS. Monitoring internal load parameters during simulated and official basketball matches. J Strength Cond Res 26(3): 861-866, 2012-The purpose of this study was to compare the internal load responses (session rating of perceived exertion [RPE] and salivary cortisol) between simulated and official matches (SM and OM). Ten professional basketball players participated in 2 OMs and 2 SMs during the competition season. Subjects provided saliva samples 30 minutes before the prematch warm-up (PRE) and 10 minutes after the end of the match. Session RPE (CR-10 scale) was assessed 30 minutes after each match. The results from the 2-way analysis of variance showed significant differences for post-OM salivary cortisol as compared with pre-OM values (p < 0.05). No changes were observed for cortisol during the SM. Before the OM, a significant difference in salivary cortisol was observed as compared with pre-SM values (p < 0.05). Moreover, the OM session RPE was significantly greater than that of SM. There was a significant correlation between session RPE and cortisol changes (r = 0.75). In summary, the results of this study showed a greater magnitude of cortisol and session RPE responses after OM as compared with that after SM confirming the hypothesis that a real competition generates a greater stress response than a simulated condition does. The anticipatory effect was also observed in the OM. In addition, the results indicate that session RPE seems to be a viable tool in monitoring internal loads, and the results are useful in providing a better understanding of internal loads imposed by basketball training and competitions. The precise monitoring of these responses might help the coaches to plan appropriate loads maximizing recovery and performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A multiwall carbon nanotube/silicone rubber (MWCNT/SR) composite electrode has been used for the determination of hydrochlorothiazide (HCTZ) in pharmaceutical formulations by differential pulse voltammetry (DPV). The electro-oxidation process was evaluated by cyclic voltammetry, from which it was observed that HCTZ presents an irreversible oxidation peak at 0.82 V vs. saturated calomel electrode (SCE) in the potential range from 0.5 to 1.1 V, in Britton-Robinson buffer pH 7.0 at MWCNT/SR. HCTZ was determined by DPV using a MWCNT/SR 70% (MWCNT, m/m) composite electrode after the optimization of the experimental parameters. The linear range was from 5.0 to 70.0 mu mol L-1, with a limit of detection (LOD) of 2.6 mu mol L-1. The HCTZ was determined in pharmaceutical formulations using the proposed composite electrode and the results agreed with those from the official high performance liquid chromatography (HPLC) method within 95% confidence level, according to the t-Student test.