14 resultados para Observers

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The aim of this pilot study was to investigate whether patients with social anxiety disorder (SAD) differ from controls in the quality of skill-related behaviors displayed during a speech and in overall behavioral adequacy as perceived by observers and by the patients themselves. Design: A total of 18 SAD patients and 18 controls were screened by a diagnostic interview and took part in a 3-minute speech of their own choosing. For each videotaped speech, observers rated the adequacy of the skill-related behaviors and overall performance adequacy. After the experiment, participants were asked to rate their own overall performance adequacy. Results: The results showed that SAD patients exhibited significantly worse voice intonation and fluency of the speech, however no differences were found in global self-ratings. Moreover, the performance evaluations of the SAD group were consistent with the observers, while the controls evaluated their performance lower than the observers. Conclusions: The results are inconsistent with the cognitive model, because patients with SAD did not underestimate their performance. Compared with spontaneous interactions, the clear rules established for such social situations as speeches may result in less cognitive distortion for SAD patients. (C) 2012 Wiley Periodicals, Inc. J. Clin. Psychol. 68:397-402, 2012.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We examined achromatic contrast discrimination in asymptomatic carriers of 11778 Leber`s hereditary optic neuropathy (LHON 18 controls) and 18 age-match were also tested. To evaluate magnocellular (MC) and Parvocellular (PC) contrast discrimination, we used a version of Pokorny and Smith`s (1997) Pulsed/steady-pedestal paradigms (PPP/SPP) thought to be detected via PC and MC pathways, respectively. A luminance pedestal (four 1 degrees x 1 degrees squares) was presented on a 12 cd/m(2) surround. The luminance of one of the squares (trial square, TS) was randomly incremented for either 17 or 133 ms. Observers had to detect the TS, in a forced-choice task, at each duration, for three pedestal levels: 7, 12, 19 cd/m(2). In the SPP, the pedestal was fixed, and the TS was modulated. For the PPP, all four pedestal squares pulsed for 17 or 133 ms, and the TS was simultaneously incremented or decremented. We found that contrast discrimination thresholds of LHON carriers were significantly higher than controls` in the condition with the highest luminance of both paradigms, implying impaired contrast processing with no evidence of differential sensitivity losses between the two systems. Carriers` thresholds manifested significantly longer temporal integration than controls in the SPP, consistent with slowed MC responses. The SPP and PPP paradigms can identify contrast and temporal processing deficits in asymptomatic LHON carriers, and thus provide an additional tool for early detection and characterization of the disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Lower extremity telangiectasia affects approximately 40% of women. The demand for aesthetic treatment of these veins continues to grow. Few studies have compared laser and sclerotherapy to treat leg telangiectasias. OBJECTIVE To compare the efficacy of conventional sclerotherapy and neodymium-doped yttrium aluminum garnet (Nd:YAG) laser in the treatment of leg telangiectasias. METHODS AND MATERIALS Thirty women were enrolled in the study. One leg was randomly assigned laser treatment and the other sclerotherapy with 75% glucose solution. All patients were photographed before and after treatment. The applying physician and two independent observers rated photographic improvement of the treated areas. Complications and adverse effects were noted during follow-up. Patients answered a questionnaire that addressed pain, clearing of the vessels, and satisfaction with the results. RESULTS There was a significant difference between the modes of treatment regarding pain. Twelve patients using laser and 16 using sclerotherapy considered the clearing of the vessels to be good to excellent after three sessions of both laser and scleratherapy. Mean scores after photographic assessment were 7.9 for laser and 7.0 for sclerotherapy. CONCLUSION Lower extremity telangiectases may be treated equally well using Nd:YAG 1064-nm laser or conventional sclerotherapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare 2 methods used to determine the disk position based on sagittal magnetic resonance images. Patients and Methods: A cross-sectional study of patients with the signs and symptoms of temporomandibular disorders was conducted. The patients' ages and gender distributions were collected. The disk position diagnosis from the clinical examination was considered the primary outcome. Three observers evaluated the presence of anterior displacement on magnetic resonance images according to 2 criteria: method 1 (12-o'clock position) and method 2 (location of the intermediate zone). To assess the intraobserver variability of the 2 methods, the examiners evaluated the same magnetic resonance images at the beginning of the study (time 1) and 40 days later (time 2). The intraobserver agreement was assessed using the observed agreement and the kappa statistic. McNemar's test was used to assess the differences between each method and the clinical examination findings (P < .05). The accuracy, sensitivity, specificity, and positive and negative predictive values were calculated by comparing the diagnosis from each method with that from the clinical examination (considered the reference standard). Results: The final sample was composed of 20 subjects with a mean age of 33.0 +/- 33.7 years; 3 were men (15%) and 17 were women (85%). A statistically significant difference between the 2 methods was found. Method 1 yielded a greater percentage of anterior displaced disks (52.5%). The agreement between the clinical diagnosis and method 1 was lower (70.0%) than that between the clinical diagnosis and method 2 (87.5%). No statistically significant difference was found between the clinical diagnosis and method 2. Conclusion: The disk position should be judged according to the intermediate zone criterion. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:1534-1539, 2012

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The objective of the study was to evaluate the ability of large-volume cone-beam computed tomography (CBCT) to detect horizontal root fracture and to test the influence of a metallic post. Methods: Through the examination of 40 teeth by large-volume CBCT (20-cm height and 15-cm diameter cylinder) at 0.2-mm voxel resolution, 2 observers analyzed the samples for the presence and localization of horizontal root fracture. Results: The values of accuracy in the groups that had no metallic post ranged from 33%-68%, whereas for the samples with the metallic post, values showed a wide variation (38%-83%). Intraobserver agreement showed no statistically significant difference between the groups with/without metallic post; both ranged from very weak to weak (kappa, 0.09-0.369). Conclusions: The low accuracy and low intraobserver and interobserver agreement reflect the difficulty in performing an adequate diagnosis of horizontal root fractures through a large-volume CBCT by using a small voxel reconstruction. (J Endod 2012;38:856-859)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. Tricuspid regurgitation (TR) is the most commonly valvular dysfunction found after heart transplantation (HTx). It may be related to endomyocardial biopsy (EMB) performed for allograft rejection surveillance. Objective. This investigation evaluated the presence of tricuspid valve tissue fragments obtained during routine EMB performed after HTx and its possible effect on short-term and long-term hemodynamic status. Method. This single-center review included prospectively collected and retrospectively analyzed data. From 1985 to 2010, 417 patients underwent 3550 EMB after HTx. All myocardial specimens were reviewed to identify the presence of tricuspid valve tissue by 2 observers initially and in doubtful cases by a third observer. The echocardiographic and hemodynamic parameters were only considered for valvular functional damage analysis in cases of tricuspid tissue inadvertently removed during EMB. Results. The 417 HTx patients to 3550 EMB, including 17,550 myocardial specimens. Tricuspid valve tissue was observed in 12 (2.9%) patients corresponding to 0.07% of the removed fragments. The echocardiographic and hemodynamic parameters of these patients before versus after the biopsy showed increased TR in 2 cases (2/12; 16.7%) quantified as moderate without progression in the long term. Only the right atrial pressure showed a significant increase (P = .0420) after tricuspid injury; however, the worsening of the functional class was not significant enough in any of the subjects. Thus, surgical intervention was not required. Conclusions. Histological evidence of chordal tissue in EMB specimens is a real-world problem of relatively low frequency. Traumatic tricuspid valve injury due to EMB rarely leads to severe valvular regurgitation; only a minority of patients develop significant clinical symptoms. Hemodynamic and echocardiographic alterations are also less often observed in most patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This study compared the influence of three epoxy resin-based sealers with distinct radiopacities on the observers' ability to detect root canal filling voids during radiographic analysis. Material and methods: The root canals of 48 extracted maxillary canines were prepared and divided into three groups. Each group was laterally condensed with one sealer (AH Plus (TM), Acroseal (R) or a non-radiopaque sealer), and a longitudinal void was simulated in half of the specimens from each group (n = 8). Buccolingual radiographs were obtained and randomly interpreted for voids by a radiologist and an endodontist in a blinded fashion. Teeth were cut and inspected under a microscope to confirm the position of void. Differences in sensitivity and specificity between groups and examiners were compared using the Fisher's Exact and McNemar tests, respectively (alpha = 0.05). Results: Significantly lower sensitivity levels (p<0.05) were observed in the coronal portion of fillings performed with both radiopaque sealers. Specificity values for Acroseal (R) were significantly higher (p<0.05) in the coronal and apical portions of fillings. Conclusion: The type of root canal sealer can affect the observers' ability to detect root canal filling voids during radiographic analysis of upper single-rooted teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: A wide variety of manifestations is presented in patients with Gaucher's disease (GD), including bone, haematology and visceral disturbances. This study was conducted to ascertain the main maxillofacial abnormalities by means of clinical survey, panoramic and cone beam CT (CBCT); to compare the patient's group with an age-sex matched control group; and to correlate clinical and radiological data. Methods: Ten patients previously diagnosed with GD were submitted to clinical and radiological surveys (CBCT and panoramic radiographs). The examination consisted of anamnesis, extra- and intraoral examinations and analyses of each patient's records. Imaging data were collected from the point of view of 3 observers, and the results compared with a healthy group (20 individuals) by means of statistical analysis (Fisher's exact test). Results: Gaucher patients had significantly more manifestations than otherwise healthy carriers. The most prevalent findings were enlarged marrow spaces, generalized osteopenia and effacement of jaw structures (mandibular canal, lamina dura and mental foramen). Here we describe a case in which thickening of the maxillary sinus mucosa was observed on CBCT rather than opacification of the sinus as seen on panoramic radiographs. Pathological fractures, root resorption and delay on tooth eruption were not observed. Conclusions: A poor relationship could be observed between clinical and radiological data. Patients showed important bone manifestations, which require careful diagnostic and surgical planning whenever necessary. Although panoramic radiographs have shown significant differences, CBCT is more effective in pointing out differences between patients and a control group, thus showing it as an important tool for evaluation of Gaucher patients. Dentomaxillofacial Radiology (2012) 41, 541-547. doi: 10.1259/dmfr/143023353

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta. Methods Women with singleton pregnancies at 2440 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm3 of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm3 of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC). Results Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones. Conclusion Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited. Copyright (c) 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this controlled animal study was to investigate the effect of low-level laser therapy (LLLT) administered 30 min after injury to the Achilles tendon. The study animals comprised 16 Sprague Dawley male rats divided in two groups. The right Achilles tendons were injured by blunt trauma using a mini guillotine, and were treated with LLLT or placebo LLLT 30 min later. The injury and LLLT procedures were then repeated 15 hours later on the same tendon. One group received active LLLT (lambda = 904 nm, 60 mW mean output power, 0.158 W/cm(2) for 50 s, energy 3 J) and the other group received placebo LLLT 23 hours after LLLT. Ultrasonographic images were taken to measure the thickness of the right and left Achilles tendons. Animals were then killed, and all Achilles tendons were tested for ultimate tensile strength (UTS). All analyses were performed by blinded observers. There was a significant increase in tendon thickness in the active LLLT group when compared with the placebo group (p < 0.05) and there were no significant differences between the placebo and uninjured left tendons. There were no significant differences in UTS between laser-treated, placebo-treated and uninjured tendons. Laser irradiation of the Achilles tendon at 0.158 W/cm(2) for 50 s (3 J) administered within the first 30 min after blunt trauma, and repeated after 15 h, appears to lead to edema of the tendon measured 23 hours after LLLT. The guillotine blunt trauma model seems suitable for inflicting tendon injury and measuring the effects of treatment on edema by ultrasonography and UTS. More studies are needed to further refine this model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The objective of this study is to compare subjective image quality and diagnostic validity of cone-beam CT (CBCT) panoramic reformatting with digital panoramic radiographs. Materials and methods: Four dry human skulls and two formalin-fixed human heads were scanned using nine different CBCTs, one multi-slice CT (MSCT) and one standard digital panoramic device. Panoramic views were generated from CBCTs in four slice thicknesses. Seven observers scored image quality and visibility of 14 anatomical structures. Four observers repeated the observation after 4 weeks. Results: Digital panoramic radiographs showed significantly better visualization of anatomical structures except for the condyle. Statistical analysis of image quality showed that the 3D imaging modalities (CBCTs and MSCT) were 7.3 times more likely to receive poor scores than the 2D modality. Yet, image quality from NewTom VGi® and 3D Accuitomo 170® was almost equivalent to that of digital panoramic radiographs with respective odds ratio estimates of 1.2 and 1.6 at 95% Wald confidence limits. A substantial overall agreement amongst observers was found. Intra-observer agreement was moderate to substantial. Conclusions: While 2D-panoramic images are significantly better for subjective diagnosis, 2/3 of the 3D-reformatted panoramic images are moderate or good for diagnostic purposes. Clinical relevance: Panoramic reformattings from particular CBCTs are comparable to digital panoramic images concerning the overall image quality and visualization of anatomical structures. This clinically implies that a 3D-derived panoramic view can be generated for diagnosis with a recommended 20-mm slice thickness, if CBCT data is a priori available for other purposes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The sealers can be in direct contact with the periapical tissues. Thus, these materials must have appropriate physical and biological properties, providing conditions for repair to occur. Objective: The aim of this study was to evaluate the response of rat subcutaneous tissue to endodontics sealers. Material and methods: Three materials comprised the groups: group I – Zinc Oxide, Eugenol and Iodoform paste, group II – Portland cement with propylene glycol, and group III – MTA Fillapex® (Angelus). These materials were placed in polyethylene tubes and implanted into dorsal connective tissue of Wistar rats for seven and 15 days. The specimens were stained with hematoxylin and eosin and evaluated regarding to inflammatory reaction parameters through a light microscope. The data were compared using Kruskal-Wallis test with significance level of 5%. The intensity of inflammatory response against the sealers was analyzed by two blinded and previously calibrated observers for all experimental periods. Results: The histological evaluation showed that all the materials caused a moderated inflammatory reaction at seven days which decreased with time. A greater inflammatory reaction was observed at seven days in group I. The other specimens had significantly less inflammatory cells when compared to this group. Tubes with MTA Fillapex® presented some giant cells, macrophages and lymphocytes after seven days. At 15 days, the presence of fibroblasts and collagen fibers was observed indicating normal tissue healing. The group II showed similar results to those observed in MTA Fillapex® already at seven days. At 15 days the inflammatory reaction presented was almost absent at the tissue, with many collagen fibers indicating normal tissue healing. Statistical analysis showed a significant statistical difference amongst the group I (seven days) and II (15 days) (p < 0.05). In the other groups no (Continue)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The sealers can be in direct contact with the periapical tissues. Thus, these materials must have appropriate physical and biological properties, providing conditions for repair to occur. Objective: The aim of this study was to evaluate the response of rat subcutaneous tissue to endodontics sealers. Material and methods: Three materials comprised the groups: group I – Zinc Oxide, Eugenol and Iodoform paste, group II – Portland cement with propylene glycol, and group III – MTA Fillapex® (Angelus). These materials were placed in polyethylene tubes and implanted into dorsal connective tissue of Wistar rats for seven and 15 days. The specimens were stained with hematoxylin and eosin and evaluated regarding to inflammatory reaction parameters through a light microscope. The data were compared using Kruskal-Wallis test with significance level of 5%. The intensity of inflammatory response against the sealers was analyzed by two blinded and previously calibrated observers for all experimental periods. Results: The histological evaluation showed that all the materials caused a moderated inflammatory reaction at seven days which decreased with time. A greater inflammatory reaction was observed at seven days in group I. The other specimens had significantly less inflammatory cells when compared to this group. Tubes with MTA Fillapex® presented some giant cells, macrophages and lymphocytes after seven days. At 15 days, the presence of fibroblasts and collagen fibers was observed indicating normal tissue healing. The group II showed similar results to those observed in MTA Fillapex® already at seven days. At 15 days the inflammatory reaction presented was almost absent at the tissue, with many collagen fibers indicating normal tissue healing. Statistical analysis showed a significant statistical difference amongst the group I (seven days) and II (15 days) (p < 0.05). In the other groups no significant statistical differences were observed. Conclusion: MTA Fillapex® and Portland cement with propylene glycol were more biocompatible than the other tested cements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has consistently been shown that agents judge the intervals between their actions and outcomes as compressed in time, an effect named intentional binding. In the present work, we investigated whether this effect is result of prior bias volunteers have about the timing of the consequences of their actions, or if it is due to learning that occurs during the experimental session. Volunteers made temporal estimates of the interval between their action and target onset (Action conditions), or between two events (No-Action conditions). Our results show that temporal estimates become shorter throughout each experimental block in both conditions. Moreover, we found that observers judged intervals between action and outcomes as shorter even in very early trials of each block. To quantify the decrease of temporal judgments in experimental blocks, exponential functions were fitted to participants’ temporal judgments. The fitted parameters suggest that observers had different prior biases as to intervals between events in which action was involved. These findings suggest that prior bias might play a more important role in this effect than calibration-type learning processes.