Resumo:
Introduction: The implementation of hearing screening programs can be facilitated by reducing operating costs, including the cost of equipment. The Telessaúde (TS) audiometer is a low-cost, software-based, and easy-to-use piece of equipment for conducting audiometric screening. Aim: To evaluate the TS audiometer for conducting audiometric screening. Methods: A prospective randomized study was performed. Sixty subjects, divided into those who did not have (group A, n = 30) and those who had otologic complaints (group B, n = 30), underwent audiometric screening with conventional and TS audiometers in a randomized order. Pure tones at 25 dB HL were presented at frequencies of 500, 1000, 2000, and 4000 Hz. A "fail" result was considered when the individual failed to respond to at least one of the stimuli. Pure-tone audiometry was also performed on all participants. The concordance of the results of screening with both audiometers was evaluated. The sensitivity, specificity, and positive and negative predictive values of screening with the TS audiometer were calculated. Results: For group A, 100% of the ears tested passed the screening. For group B, "pass" results were obtained in 34.2% (TS) and 38.3% (conventional) of the ears tested. The agreement between procedures (TS vs. conventional) ranged from 93% to 98%. For group B, screening with the TS audiometer showed 95.5% sensitivity, 90.4% sensitivity, and positive and negative predictive values equal to 94.9% and 91.5%, respectively. Conclusions: The results of the TS audiometer were similar to those obtained with the conventional audiometer, indicating that the TS audiometer can be used for audiometric screening.
Resumo:
OBJETIVO: Analisar os motivos da evasão familiar no programa de triagem auditiva neonatal realizado em um hospital público e correlacioná-los com a distribuição demográfica das famílias e as características do programa. MÉTODOS: Participaram 132 famílias, de um total de 739 contatadas, cujos filhos nasceram em uma maternidade no interior do estado de São Paulo de outubro/2003 a dezembro/2005 e que não haviam comparecido para a realização do teste ou reteste da triagem auditiva neonatal. Foi aplicado um questionário de levantamento das causas de evasão, contendo perguntas relacionadas à triagem auditiva, nível de escolaridade e profissão dos pais e também sobre a audição e o desenvolvimento de linguagem da criança. RESULTADOS: Realizou-se a aplicação do questionário com 132 famílias (17,86%); com as demais não foi obtido contato. Deste total, 82 haviam faltado na primeira etapa da triagem auditiva (teste) e 50 não haviam retornado para realização do reteste. Os motivos mais frequentes para justificar a evasão foram o desinteresse e a dificuldade em conciliar o agendamento com a rotina familiar. Não houve associação entre os motivos da evasão e o nível de escolaridade e ocupação dos pais, nem com o profissional que realizou a orientação acerca da triagem auditiva. Não foi referido nenhum caso de alteração auditiva, nem de atraso significativo no desenvolvimento da linguagem. CONCLUSÃO: Os motivos da evasão familiar independem de variáveis voltadas à família e à dinâmica do programa de triagem auditiva.
Resumo:
Purpose: To validate a monitoring questionnaire about hearing and language development applied by community health agents in the first year of life. Methods: Seventy six community health agents, previously trained on infant hearing health, administered a questionnaire to the families of 304 children with ages from 0 to 1 year. The questionnaire contains questions regarding hearing and language development and, for all age groups, the question “Does your child hear well?” was presented. The validity of the questionnaire was assessed by analyzing false positive and false negative rates of the identified children. A double-blind study was conducted so that all children assessed by the questionnaire were submitted to hearing evaluation performed by audiologists. Results: Four children (1.32%) were diagnosed with sensorineural hearing loss (two unilateral), and 69 (22.7%) with conductive hearing loss. The monitoring questionnaire showed specificity of 96% and sensitivity of 67%, with a false-negative rate of 33% for not identifying the unilateral hearing loss, and a false-positive rate of 4%. Conclusion: The questionnaire used has shown to be feasible and relevant to actions of the community health agents of the Family Health Strategy program, with high specificity and moderate sensitivity. The use of the validated instrument should be considered to complement Newborn Hearing Screening Programs, in order to identify late onset or acquired hearing loss.
Resumo:
Purpose: to describe the proposal of monitoring children in the first year of life, who were not identified in the newborn hearing screening program but had risk factors for hearing loss. Method: the study included 258 risk children who had obtained the result “pass” in the Universal Newborn Hearing Screening Program of Hospital Santa Isabel – Bauru/SP, from June to November 2008. It was applied by the telephone, a validated questionnaire in a previous study, containing questions about hearing and language. For each question there were two possible answers: “yes” or “no” and we considered “failure” to obtain at least one “no” answer. With such result, the child was scheduled to perform an immediate hearing evaluation. Results: the questionnaire was applied with 169 families; with the others, there was no contact. From the total, 164 (97,04%) obtained “passed” and five (2,96%) “failed”. Between these five children, only three showed up for hearing evaluation and one had no disorders; two presented conductive hearing loss. It was observed distinct prevalence among the risk factors and there was no relation (p>0,05) of the risk factors with the evasion in the monitoring process. Conclusion: the monitoring through a questionnaire applied by telephone proved to be feasible, however, it is necessary to develop strategies to support their execution.
Resumo:
Objective To evaluate the effectiveness of two screening methods (imitanciometry screening and questionnaire) to identify children at risk for conductive hearing loss, comparing this data with complete audiologic evaluation. Methods Of 507 children aged between three and six, 111 completed all procedures. The observational methods used were: imitanciometry screening, a questionnaire to identify risk factors for hearing loss and complete audiologic evaluation. Results obtained in the first two instruments were compared with results from complete audiologic evaluation (gold standard). From these comparisons, sensitivity and specificity, accuracy, positive and negative predictive values, and odds ratio were determined for the two screening methods and for the combination of both methods. Results The two methods applied in series (questionnaire and after imitanciometry screening) showed a greater odds ratio and better correlation between sensitivity and proportion of false-positives (ROC curve). Conclusion Combining the two tests in series improved screening accuracy. This combination was the best tool for identifying children at risk for conductive hearing loss.
Resumo:
This study evaluated the impact of a participatory program to reduce noise in a neonatal intermediate care unit of a university hospital. A time-series quasi-experimental design was used, in which sound pressure levels were measured before and after the intervention was implemented using the Quest-400 dosimeter. Non-parametric statistical tests were used to compare noise with the level of significance fixed at 5%. Results showed significant reduction of sound pressure levels in the neonatal unit after the intervention program was implemented (p<0.0001). The average Leq before the intervention was 62.5dBA and was reduced to 58.8dBA after the intervention. A reduction of 7.1dBA in the average Lmax(from 104.8 to 87.7dBA) and of 30.6dBA in the average Lpeak(from 138.1 to 107.5dBA) was observed. The program was proven to be effective in significantly reducing noise levels in the neonatal unit, although levels were still more intense than recommended.