11 resultados para Measuring CDS Returns
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
SHERMAN, D.J.; LI, B.; FERRELL E.J.; ELLIS, J.T.; COX, W.D.; MAIA, L.P., and SOUSA, P.H.G.O., 2011. Measuring Aeolian Saltation: A Comparison of Sensors. In: Roberts, T.M., Rosati, J.D., and Wang, P. (eds.), Proceedings, Symposium to Honor Dr. Nicholas C. Kraus, Journal of Coastal Research, Special Issue, No. 59, pp. 280-290. West Palm Beach (Florida), ISSN 0749-0208. We report the results of field experiments designed to compare four types of aeolian saltation sensors: the Safire; the Wenglor (R) Particle Counter; the Miniphone; and the Buzzer Disc. Sets of sensors were deployed in tight spatial arrays and sampled at rates as fast as 20 kHz. In two of the three trials, the data from the sensors are compared to data obtained from sand traps. The Miniphone and the Buzzer Disc, based on microphone and piezoelectric technologies, respectively, produced grain impact counts comparable to those derived from the trap data. The Satire and the Wenglor (R) Particle Counter produce count rates that were an order of magnitude too slow. Satires undercount because of their large momentum threshold and because its signal is saturated at relatively slow transport rates. We conclude that the Miniphone and the Buzzer Disc are appropriate for deployment as grain counters because their small size allows them to be installed in closely-spaced sets.
Resumo:
This study aimed to evaluate adherence to anti-retroviral treatment (ART) among HIV + adults, assess its association with HIV viral load (VL) and identify factors associated to adherence. A survey involving a random sample of adults followed at a HIV/AIDS reference center in Sao Paulo city, Brazil, from 2007 to 2009 was done. A questionnaire was applied and data were retrieved from the pharmacy and medical records. The study involved 292 subjects: 70.2% men; median age: 43 years; median duration of ART: 8 years. 89.3% self-reported taken all prescribed pills in the last 3 days but only 39.3% picked up >= 95% of the prescribed ART from the pharmacy in the last 12 months. At the multivariate analysis having symptoms prior to ART, taking fewer ART pills, and not missing medical appointments were independently associated to higher adherence. Adherence was strongly associated with undetectable HIV VL. Rates of undetectable HIV VL did not differ from 80 to >= 95% of adherence.
Resumo:
Objective: To describe clinical and laboratory characteristics in patients with tuberculosis-related or lymphoma-related lymphocytic pleural effusions, in order to identify the variables that might contribute to differentiating between these diseases. Methods: This was a retrospective study involving 159 adult HIV-negative patients with tuberculosis-related or lymphoma-related lymphocytic effusions (130 and 29 patients, respectively), treated between October of 2008 and March of 2010 at the Pleural Diseases Outpatient Clinic of the University of Sao Paulo School of Medicine Hospital das Clinicas Heart Institute, in the city of Sao Paulo, Brazil. Results: Mean age and the mean duration of symptoms were lower in the tuberculosis group than in the lymphoma group. The levels of proteins, albumin, cholesterol, amylase, and adenosine deaminase (ADA) in pleural fluid, as well as the serum levels of proteins, albumin, and amylase, were higher in the tuberculosis group, whereas serum cholesterol and triglycerides were higher in the lymphoma group. Pleural fluid leukocyte and lymphocyte counts were higher in the tuberculosis group. Of the tuberculosis group patients, none showed malignant cells; however, 4 showed atypical lymphocytes. Among the lymphoma group patients, cytology for neoplastic cells was positive, suspicious, and negative in 51.8%, 24.1%, and 24.1%, respectively. Immunophenotyping of pleural fluid was conclusive in most of the lymphoma patients. Conclusions: Our results demonstrate clinical and laboratory similarities among the patients with tuberculosis or lymphoma. Although protein and ADA levels in pleural fluid tended to be higher in the tuberculosis group than in the lymphoma group, even these variables showed an overlap. However, none of the tuberculosis group patients had pleural fluid ADA levels below the 40-U/L cut-off point.
Resumo:
We report on the strong temperature-dependent thermal expansion, alpha(D), in CdS quantum dots (QDs) embedded in a glass template. We have performed a systematic study by using the temperature-dependent first-order Raman spectra, in CdS bulk and in dot samples, in order to assess the size dependence of alpha(D), and where the role of the compressive strain provoked by the glass host matrix on the dot response is discussed. We report the Gruneisen mode parameters and the anharmonic coupling constants for small CdS dots with mean radius R similar to 2.0 nm. We found that gamma parameters change, with respect to the bulk CdS, in a range between 20 and 50%, while the anharmonicity contribution from two-phonon decay channel becomes the most important process to the temperature-shift properties.
Resumo:
The filter paper method is one of the most commonly used and critiqued techniques for measuring soil suction. However, many aspects related to its use still require some clarification. The results of a comprehensive study on the effect of the contact between the soil grains and soil water and the filter paper are presented herein. We investigated the influence of the equilibration time, the texture of the porous material and the degree of contact, or lack thereof, between the soil grains and the filter paper using Miamian #42 and three different types of porous material. To enhance the difference between the total suction and the matrix suction, osmotic suction was induced by saturating the specimens with a sodium chloride solution.
Resumo:
'Objectives: To analyse the validity of the Brazilian versions of OHIP-EDENT and GOHAI as assessment tools of edentulous subjects' OHRQoL. Background: Inventories for measuring oral health-related quality of life (OHRQoL) are important in clinical studies regarding oral rehabilitation. However, there is a need for comprehensive validation after translation into different cultural settings. Materials and methods: The sample comprised of 100 complete denture wearers (29 men, 71 women, mean age of 65.2 +/- 9.9 years). The associations between each OHRQoL inventory and other variables served as measurements of construct validity. Data analysis comprised the Spearman correlation test as well as multiple regression using the OHRQoL inventories as dependent variables and the other scales as determinants. Results: Both OHRQoL inventories showed good correlation with denture satisfaction, whereas lower correlation coefficients were found among the inventories and the HAD subscales. Denture satisfaction alone explained 48% and 39% of the variance found for the OHIP-EDENT and GOHAI, respectively, as assessed by multiple regression. A smaller effect was found for OHIP-EDENT. Conclusion: Both OHIP-EDENT and GOHAI showed good construct validity for measurement of OHRQoL of edentulous subjects.
Resumo:
Deutsche Forschungsgemeinschaft [SFB 858]
Resumo:
In the present work we revisit the size data of CdS microcrystals previously collected in the glassy matrix of Germanium oxide. The CdS clusters analyzed using electron microscopy images have shown a wurtzite structure. The mean average radius, dispersion and volume evaluated from the histograms showed good agreement for t(1/3), t(2/3) and t laws, respectively. We observed that the amount of microcrystals remains constant throughout the heat treatment process, as well as that the radii distribution has a lower limit and increases with heat treatment. The distribution of radii follows a distribution similar to the Lifshitz-Slyozov-Wagner distribution limited in the origin. Discussions led to the conclusion that the growth of CdS is a process that occurs after the fluctuating nucleation and coalescence phases. We then analyze the growth process, assuming that the evaporation is overcome by the precipitation rate, stabilizing all clusters with respect to dissolution back into the matrix. The problem was simplified neglecting anisotropy and the assuming a spherical shape for clusters and particles. The low interface tension was described in terms of an empirical potential barrier in the surface of the cluster. The growth dynamics developed considering that the number of clusters remains constant, and that the minimum size of these clusters grow with time, as the first order approximation showed a good agreement with the flaw. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
The analysis of spatial relations among objects in an image is an important vision problem that involves both shape analysis and structural pattern recognition. In this paper, we propose a new approach to characterize the spatial relation along, an important feature of spatial configurations in space that has been overlooked in the literature up to now. We propose a mathematical definition of the degree to which an object A is along an object B, based on the region between A and B and a degree of elongatedness of this region. In order to better fit the perceptual meaning of the relation, distance information is included as well. In order to cover a more wide range of potential applications, both the crisp and fuzzy cases are considered. In the crisp case, the objects are represented in terms of 2D regions or ID contours, and the definition of the alongness between them is derived from a visibility notion and from the region between the objects. However, the computational complexity of this approach leads us to the proposition of a new model to calculate the between region using the convex hull of the contours. On the fuzzy side, the region-based approach is extended. Experimental results obtained using synthetic shapes and brain structures in medical imaging corroborate the proposed model and the derived measures of alongness, thus showing that they agree with the common sense. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Abstract Background The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. Methods The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. Results Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. Conclusion By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively.
Resumo:
The Pierre Auger Observatory in Malargüe, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 1018 eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, located near the center of the observatory site, having an optical signature comparable to that of the highest energy showers detected by the FD. This paper presents two procedures developed to retrieve the aerosol attenuation of fluorescence light from CLF laser shots. Cross checks between the two methods demonstrate that results from both analyses are compatible, and that the uncertainties are well understood. The measurements of the aerosol attenuation provided by the two procedures are currently used at the Pierre Auger Observatory to reconstruct air shower data.