7 resultados para Measurement system

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The stability of oil-in-water (O/W) emulsions used as metalworking fluids is a key factor for the economical and environmental balance of the entire metalworking process because used and broken fluids must be recycled or disposed. In this study, the ability of turbidimetric spectroscopy in the ultraviolet and visible light range to detect metalworking fluids destabilization was evaluated. Destabilization was achieved by adding calcium chloride, thus achieving accelerated aging, which leads to coalescence, creaming, and complete emulsion separation. The stability of the metalworking fluids at 5% volumetric concentration in deionized water was monitored using a spectroscopic turbidimeter composed of an optical probe for in-line measurements. Destabilization was also monitored by measuring the vertical profile of backscattered and transmitted light. The results of this offline measurement system were compared with those from the in-line spectroscopic sensor, indicating that the latter can provide local, real-time information on emulsion destabilization, thus enabling control actions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The concept of industrial clustering has been studied in-depth by policy makers and researchers from many fields, mainly due to the competitive advantages it may bring to regional economies. Companies often take part in collaborative initiatives with local partners while also taking advantage of knowledge spillovers to benefit from locating in a cluster. Thus, Knowledge Management (KM) and Performance Management (PM) have become relevant topics for policy makers and cluster associations when undertaking collaborative initiatives. Taking this into account, this paper aims to explore the interplay between both topics using a case study conducted in a collaborative network formed within a cluster. The results show that KM should be acknowledged as a formal area of cluster management so that PM practices can support knowledge-oriented initiatives and therefore make better use of the new knowledge created. Furthermore, tacit and explicit knowledge resulting from PM practices needs to be stored and disseminated throughout the cluster as a way of improving managerial practices and regional strategic direction. Knowledge Management Research & Practice (2012) 10, 368-379. doi:10.1057/kmrp.2012.23

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Air pollution is associated with a substantial burden on human health; however, the most important pollutants may vary with location. Proper monitoring is necessary to determine the effect of these pollutants on respiratory health. Objectives: This study was designed to evaluate the role of outdoor, indoor and personal exposure to combustion-related pollutants NO2 and O-3 on respiratory health of children in a non-affluent urban area of Sao Paulo, Brazil. Methods: Levels of NO2 and O-3 were continuously measured in outdoor and indoor air, as well as personal exposure, for 30 days using passive measurement monitors. Respiratory health was assessed with a Brazilian version of the ISAAC questionnaire. Results: Complete data were available from 64 children, aged 6-10 years. Respiratory morbidity was high, with 43 (67.2%) reporting having had wheezing at any time, 27 (42.2%) wheezing in the last month, 17 (26.6%) asthma at any time and 21(32.8%) pneumonia at any time. Correlations between levels of NO2 and O-3 measured in the three locations evaluated were poor. Levels of NO2 in indoor air and personal exposure to O-3 were independently associated with asthma (both cases P=.02), pneumonia (O-3, P=.02) and wheezing at any time (both cases P<.01). No associations were seen between outdoor NO2 and O-3 and respiratory health. Conclusions: Exposure to higher levels of NO2 and O-3 was associated with increased risk for asthma and pneumonia in children. Nonetheless, the place where the pollutants are measured influences the results. The measurements taken in indoor and personal exposure were the most accurate. (C) 2012 SEPAR. Published by Elsevier Espana, S.L. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The free-carrier absorption cross-section sigma of a magnetic colloid composed of magnetite nanoparticles dispersed in oil is obtained by using the Z-scan technique in different experimental conditions of the laser beam. We show that it is possible to obtain sigma with picosecond pulsed and millisecond chopped beams with pulse frequencies smaller than about 30 Hz. For higher pulse frequencies, the heating of the colloidal system triggers the appearance of the Soret effect. This effect artificially increases the value of sigma calculated from the experimental results. The limits of the different experimental setups are discussed. (C) 2012 Optical Society of America

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This new and general method here called overflow current switching allows a fast, continuous, and smooth transition between scales in wide-range current measurement systems, like electrometers. This is achieved, using a hydraulic analogy, by diverting only the overflow current, such that no slow element is forced to change its state during the switching. As a result, this approach practically eliminates the long dead time in low-current (picoamperes) switching. Similar to a logarithmic scale, a composition of n adjacent linear scales, like a segmented ruler, measures the current. The use of a linear wide-range system based on this technique assures fast and continuous measurement in the entire range, without blind regions during transitions and still holding suitable accuracy for many applications. A full mathematical development of the method is given. Several computer realistic simulations demonstrated the viability of the technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

System thinking allows companies to use subjective constructs indicators like recursiveness, cause-effect relationships and autonomy to performance evaluation. Thus, the question that motivates this paper is: Are Brazilian companies searching new performance measurement and evaluation models based on system thinking? The study investigates models looking for system thinking roots in their framework. It was both exploratory and descriptive based on a multiple four case studies strategy in chemical sector. The findings showed organizational models have some characteristics that can be related to system thinking as system control and communication. Complexity and autonomy are deficiently formalized by the companies. All data suggest, inside its context, that system thinking seems to be adequate to organizational performance evaluation but remains distant from the management proceedings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. Methods The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. Results Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. Conclusion By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively.