4 resultados para LI-FRAUMENI
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Background: Li-Fraumeni (LFS) and Li-Fraumeni-like (LFL) syndromes are associated to germline TP53 mutations, and are characterized by the development of central nervous system tumors, sarcomas, adrenocortical carcinomas, and other early-onset tumors. Due to the high frequency of breast cancer in LFS/LFL families, these syndromes clinically overlap with hereditary breast cancer (HBC). Germline point mutations in BRCA1, BRCA2, and TP53 genes are associated with high risk of breast cancer. Large rearrangements involving these genes are also implicated in the HBC phenotype. Methods: We have screened DNA copy number changes by MLPA on BRCA1, BRCA2, and TP53 genes in 23 breast cancer patients with a clinical diagnosis consistent with LFS/LFL; most of these families also met the clinical criteria for other HBC syndromes. Results: We found no DNA copy number alterations in the BRCA2 and TP53 genes, but we detected in one patient a 36.4 Kb BRCA1 microdeletion, confirmed and further mapped by array-CGH, encompassing exons 9-19. Breakpoints sequencing analysis suggests that this rearrangement was mediated by flanking Alu sequences. Conclusion: This is the first description of a germline intragenic BRCA1 deletion in a breast cancer patient with a family history consistent with both LFL and HBC syndromes. Our results show that large rearrangements in these known cancer predisposition genes occur, but are not a frequent cause of cancer susceptibility.
Resumo:
In this work, the energy response functions of Si(Li), SDD and CdTe detectors were studied in the mammographic energy range through Monte Carlo simulation. The code was modified to take into account carrier transport effects and the finite detector energy resolution. The results obtained show that all detectors exhibit good energy response at low energies. The most important corrections for each detector were discussed, and the corrected mammographic x-ray spectra obtained with each one were compared. Results showed that all detectors provided similar corrected spectra, and, therefore, they could be used to accurate mammographic x-ray spectroscopy. Nevertheless, the SDD is particularly suitable for clinic mammographic x-ray spectroscopy due to the easier correction procedure and portability. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
We present a direct measurement of the low-energy Li-8(p, alpha)He-5 cross section, using a radioactive Li-8 beam impinging on a thick target. With four beam energies, we cover the energy range between E-c.m. = 0.2 and 2.1 MeV. An R-matrix analysis of the data is performed and suggests the existence of two broad overlapping resonances (5/2(+) at E-c.m. = 1.69 MeV and 7/2(+) at E-c.m. = 1.76 MeV). At low energies our data are sensitive to the properties of a subthreshold state (E-x = 16.67 MeV) and of two resonances above threshold. These resonances were observed in previous experiments. The R-matrix fit confirms spin assignments, and provides partial widths. We propose a new Li-8(p, alpha)He-5 reaction rate and briefly discuss its influence in nuclear astrophysics. DOI: 10.1103/PhysRevC.86.064321
Resumo:
A detailed characterization of a X-ray Si(Li) detector was performed to obtain the energy dependence of efficiency in the photon energy range of 6.4 - 59.5 keV. which was measured and reproduced by Monte Carlo (MC) simulations. Significant discrepancies between MC and experimental values were found when lhe manufacturer parameters of lhe detector were used in lhe simulation. A complete Computerized Tomagraphy (CT) detector scan allowed to find the correct crystal dimensions and position inside the capsule. The computed efficiencies with the resulting detector model differed with the measured values no more than 10% in most of the energy range.