11 resultados para International Brotherhood of Electrical Workers
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Shift workers from control centers of electrical systems are a group that has received little attention in Brazil. This study aimed to compare workers' job satisfaction at five control centers of a Brazilian company electrical system, and according to their job titles. Method: The Organization Satisfaction Index (OSI) questionnaire to assess job satisfaction was used. ANOVA was used to compare OSI means, according to job title and control center. The results showed that there is no difference in job satisfaction among job titles, but a significant difference was found according to the control center. A single organizational culture cannot be applied to several branches. It is required to implement actions that would result in job satisfaction improvements among workers of all studied control rooms centers. The high level of education of operators working in all centers might have contributed to the similar values of perceived satisfaction among distinct job titles.
Resumo:
The CIPESC (R) is a tool that informs the work of nurses in Public Health and assists in prioritizing their care in practice, management and research. It is also a powerful pedagogical instrument for the qualification of nurses within the Brazilian healthcare system. In the teaching of infectious diseases, using the CIPESC (R) assists in analyzing the interventions by encouraging clinical and epidemiological thinking regarding the health-illness process. With the purpose in mind of developing resources for teaching undergraduate nursing students and encouraging reflection regarding the process of nursing work, this article presents an experimental application of CIPESC (R), using meningococcal meningitis as an example.
Resumo:
This work presents the application of Linear Matrix Inequalities to the robust and optimal adjustment of Power System Stabilizers with pre-defined structure. Results of some tests show that gain and zeros adjustments are sufficient to guarantee robust stability and performance with respect to various operating points. Making use of the flexible structure of LMI's, we propose an algorithm that minimizes the norm of the controllers gain matrix while it guarantees the damping factor specified for the closed loop system, always using a controller with flexible structure. The technique used here is the pole placement, whose objective is to place the poles of the closed loop system in a specific region of the complex plane. Results of tests with a nine-machine system are presented and discussed, in order to validate the algorithm proposed. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
The installation of induction distributed generators should be preceded by a careful study in order to determine if the point of common coupling is suitable for transmission of the generated power, keeping acceptable power quality and system stability. In this sense, this paper presents a simple analytical formulation that allows a fast and comprehensive evaluation of the maximum power delivered by the induction generator, without losing voltage stability. Moreover, this formulation can be used to identify voltage stability issues that limit the generator output power. All the formulation is developed by using the equivalent circuit of squirrel-cage induction machine. Simulation results are used to validate the method, which enables the approach to be used as a guide to reduce the simulation efforts necessary to assess the maximum output power and voltage stability of induction generators. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The interpretation of the effect of plastic deformation on the calculated excess loss component (anomalous-loss) supports the concept of loss separation. Magnetic losses and Barkhausen noise of nonoriented electrical steel sheets were measured on Epstein strips taken from a single coil of 0.8% Si nonoriented electrical steel. Sheets were extracted in the annealed condition, without any skin pass and with a grain size of 18 mu m. This material was cold rolled in order to obtain sets of samples with true strain from 2% up to 29%. X-ray diffraction was used to estimate the dislocation density. The analysis of magnetic properties was performed by Barkhausen noise measurements and also by analyzing the hysteresis loops obtained from Epstein frame measurements for different inductions and different frequencies (including the quasi-static regime for hysteresis loss measurements). These data allowed us to observe that most of the well known total loss increase with plastic deformation is due to an increase in the hysteresis loss component, while excess loss decreases to become negligible. This behavior can be explained if it is assumed that the plastic deformation lead to an increase in the number of domain walls per unit volume, thereby decreasing the excess loss. Barkhausen peak area increases with plastic deformation, reproducing results taken from samples of different silicon content.
Resumo:
In this paper, a new algebraic-graph method for identification of islanding in power system grids is proposed. The proposed method identifies all the possible cases of islanding, due to the loss of a equipment, by means of a factorization of the bus-branch incidence matrix. The main features of this new method include: (i) simple implementation, (ii) high speed, (iii) real-time adaptability, (iv) identification of all islanding cases and (v) identification of the buses that compose each island in case of island formation. The method was successfully tested on large-scale systems such as the reduced south Brazilian system (45 buses/72 branches) and the south-southeast Brazilian system (810 buses/1340 branches). (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
There is a considerable number of researches about workplace violence, but few relate young workers and work harassment. This study aimed to investigate the reported perceptions of young apprentices and trainees about moral harassment at work and related coping strategies. Forty adolescent workers (22 men and 18 women) between 15 and 20 years old who received training by a non-governmental organization in Sao Paulo, Brazil, participated in the study. Data collection included individual and collective interviews. It was used an in-depth semi structured interview protocol. The discourses were analyzed using the hermeneutic-dialectic frame. Results showed that young workers reported little or no knowledge of strategies to cope with moral harassment at work, showing vulnerability to the effects of aggression. Effective coping strategies at work should embrace two important concepts of health promotion: empowerment and autonomy.
Resumo:
The objective of this study was to verify the effect of acupuncture on the sleep quality of obese workers in a teaching hospital. Data were collected from July to October 2009, focusing on 37 workers who attended eight weekly acupuncture sessions. The Pittsburgh Sleep Quality Index was used to assess their sleep quality before and after the intervention. Results show that before the intervention, five (13.5%) people experienced good quality of sleep whereas at the end of the study 14 (37.8%) showed this condition. Statistic significance (p=0.0001) was found in comparing the mean scores obtained before and after acupuncture. Acupuncture had effects on the quality of sleep in the studied sample, presenting itself as a complementary technique for treating sleep disorders and consequently improving the quality of life in this population.
Resumo:
Plasticized natural macromolecules-based polymer electrolyte samples were prepared and characterized. The plasticization of chitosonium acetate with glycerol increased the ionic conductivity value from 3.0 x 10(-7) S/cm to 1.1 x 10(-5) S/cm. The conductivity temperature relationship of the samples exhibits either VTF or Arrhenius type depending on the glycerol concentration in the sample. The dielectric studies evidencing the relaxation process in the plasticized sample at low frequency region are due to the electric polarization effect. Moreover, the samples were transparent in the Vis region, showed thermal stability up to 160 degrees C and good surface uniformity.
Resumo:
Background: Brazil is the world's largest producer of sugarcane. Harvest is predominantly manual, exposing workers to health risks: intense physical exertion, heat, pollutants from sugarcane burning. Design: Panel study to evaluate the effects of burnt sugarcane harvesting on blood markers and on cardiovascular system. Methods: Twenty-eight healthy male workers, living in the countryside of Brazil were submitted to blood markers, blood pressure, heart rate variability, cardiopulmonary exercise testing, sympathetic nerve activity evaluation and forearm blood flow measures (venous occlusion plethysmography) during burnt sugarcane harvesting and four months later while they performed other activities in sugar cane culture. Results: Mean participant age was 31 +/- 6.3 years, and had worked for 9.8 +/- 8.4 years on sugarcane work. Work during the harvest period was associated with higher serum levels of Creatine Kinase - 136.5 U/L (IQR: 108.5-216.0) vs. 104.5 U/L (IQR: 77.5-170.5), (p = 0.001); plasma Malondialdehyde-7.5 +/- 1.4 mu M/dl vs. 6.9 +/- 1.0 mu M/dl, (p = 0.058); Glutathione Peroxidase - 55.1 +/- 11.8 Ug/Hb vs. 39.5 +/- 9.5 Ug/Hb, (p < 0.001); Glutathione Transferase- 3.4 +/- 1.3 Ug/Hb vs. 3.0 +/- 1.3 Ug/Hb, (p = 0.001); and 24-hour systolic blood pressure - 120.1 +/- 10.3 mmHg vs. 117.0 +/- 10.0 mmHg, (p = 0.034). In cardiopulmonary exercise testing, rest-to-peak diastolic blood pressure increased by 11.12 mmHg and 5.13 mmHg in the harvest and non-harvest period, respectively. A 10 miliseconds reduction in rMSSD and a 10 burst/min increase in sympathetic nerve activity were associated to 2.2 and 1.8 mmHg rises in systolic arterial pressure, respectively. Conclusion: Work in burnt sugarcane harvesting was associated with changes in blood markers and higher blood pressure, which may be related to autonomic imbalance.
Resumo:
In this paper, a novel method for power quality signal decomposition is proposed based on Independent Component Analysis (ICA). This method aims to decompose the power system signal (voltage or current) into components that can provide more specific information about the different disturbances which are occurring simultaneously during a multiple disturbance situation. The ICA is originally a multichannel technique. However, the method proposes its use to blindly separate out disturbances existing in a single measured signal (single channel). Therefore, a preprocessing step for the ICA is proposed using a filter bank. The proposed method was applied to synthetic data, simulated data, as well as actual power system signals, showing a very good performance. A comparison with the decomposition provided by the Discrete Wavelet Transform shows that the proposed method presented better decoupling for the analyzed data. (C) 2012 Elsevier Ltd. All rights reserved.