Resumo:
Purpose: The study aimed to assess electrocardiographic alterations during oral implant placement surgeries under local anesthesia (lidocaine chlorhydrate with epinephrine), using 15 mg of midazolam as an anxiolytic premedication. Material and methods: The study randomly selected 20 patients, aged 21-50 years old, requiring bilateral mandibular dental implants. Each patient was assessed using placebo on one side and midazolam on the contralateral side, with random, double-blinded distribution. The electrocardiogram recorded 12 static leads every 2 min, while D2 derivations were recorded continuously. Results: No statistically significant differences were observed between the placebo and midazolam when analyzing the morphological behavior of the electrocardiographic wave and the presence of arrhythmias during the experiment. However, under sedation, assessment of the behavior of electrocardiographic parameters during different stages of the procedure revealed statistically significant differences (P<0.05) for heart rate, P-wave amplitude and duration of the RR and QTc intervals. The arrhythmias detected were considered low risk for patients without systemic alterations and were observed in 53.3% of patients. The most frequently occurring alterations were tachycardia, bradycardia, supraventricular and ventricular extrasystoles and blocked atrial extrasystole, which were similar for both placebo and midazolam, with the greatest incidence during the initial, incision and bone drilling stages. Conclusion: The use of 15 mg of midazolam made no difference compared with the placebo. The use of 15 mg of midazolam did not show an advantage in the incidence of arrhythmias The anxiolytic premedication does not prevent myocardial arrhythmias in endosseous implant placement. The clinical significance of the arrhythmias may not represent serious risks.
Resumo:
Recent studies in animals have shown pronounced resorption of the buccal bone plate after immediate implantation. The use of flapless surgical procedures prior to the installation of immediate implants, as well as the use of synthetic bone graft in the gaps represent viable alternatives to minimize buccal bone resorption and to favor osseointegration. The aim of this study was to evaluate the healing of the buccal bone plate following immediate implantation using the flapless approach, and to compare this process with sites in which a synthetic bone graft was or was not inserted into the gap between the implant and the buccal bone plate. Lower bicuspids from 8 dogs were bilaterally extracted without the use of flaps, and 4 implants were installed in the alveoli in each side of the mandible and were positioned 2.0 mm from the buccal bone plate (gap). Four groups were devised: 2.0-mm subcrestal implants (3.3 x 8 mm) using bone grafts (SCTG), 2.0-mm subcrestal implants without bone grafts (SCCG), equicrestal implants (3.3 x 10 mm) with bone grafts (EGG), and equicrestal implants without bone grafts (ECCG). One week following the surgical procedures, metallic prostheses were installed, and within 12 weeks the dogs were sacrificed. The blocks containing the individual implants were turned sideways, and radiographic imaging was obtained to analyze the remodeling of the buccal bone plate. In the analysis of the resulting distance between the implant shoulder and the bone crest, statistically significant differences were found in the SCTG when compared to the ECTG (P = .02) and ECCG (P = .03). For mean value comparison of the resulting linear distance between the implant surface and the buccal plate, no statistically significant difference was found among all groups (P > .05). The same result was observed in the parameter for presence or absence of tissue formation between the implant surface and buccal plate. Equicrestally placed implants, in this methodology, presented little or no loss of the buccal bone. The subcrestally positioned implants presented loss of buccal bone, even though synthetic bone graft was used. The buccal bone, however, was always coronal to the implant shoulder.
Resumo:
Purpose: Few reports have evaluated cumulative survival rates of extraoral rehabilitation and peri-implant soft tissue reaction at long-term follow-up. The objective of this study was to evaluate implant and prosthesis survival rates and the soft tissue reactions around the extraoral implants used to support craniofacial prostheses. Materials and Methods: A retrospective study was performed of patients who received implants for craniofacial rehabilitation from 2003 to 2010. Two outcome variables were considered: implant and prosthetic success. The following predictor variables were recorded: gender, age, implant placement location, number and size of implants, irradiation status in the treated field, date of prosthesis delivery, soft tissue response, and date of last follow-up. A statistical model was used to estimate survival rates and associated confidence intervals. We randomly selected 1 implant per patient for analysis. Data were analyzed using the Kaplan-Meier method and log-rank test to compare survival curves. Results: A total of 150 titanium implants were placed in 56 patients. The 2-year overall implant survival rates were 94.1% for auricular implants, 90.9% for nasal implants, 100% for orbital implants, and 100% for complex midfacial implants (P = .585). The implant survival rates were 100% for implants placed in irradiated patients and 94.4% for those placed in nonirradiated patients (P = .324). The 2-year overall prosthesis survival rates were 100% for auricular implants, 90.0% for nasal implants, 92.3% for orbital implants, and 100% for complex midfacial implants (P = .363). The evaluation of the peri-implant soft tissue response showed that 15 patients (26.7%) had a grade 0 soft tissue reaction, 30 (53.5%) had grade 1, 6 (10.7%) had grade 2, and 5 (8.9%) had grade 3. Conclusions: From this study, it was concluded that craniofacial rehabilitation with extraoral implants is a safe, reliable, and predictable method to restore the patient's normal appearance. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:1551-1557, 2012
Resumo:
Objective Several implant surfaces are being developed, some in the nanoscale level. In this study, two different surfaces had their early healing properties compared in context of circumferential defects of various widths. Material and methods Six dogs had the mandibular premolars extracted. After 8weeks, four implants were placed equicrestally in each side. One acted as control, while the others were inserted into sites with circumferential defects of 1.0, 1.5 and 2.0mm wide and 5mm deep. A nano-modified surface was used on one side and a micro-rough on the other. Bone markers were administered on the third day after implant placement and then after 1, 2, 4weeks to investigate the bone formation dynamic through fluorescence analysis. Ground sections were prepared from 8-week healing biopsies and histomorphometry was performed. Results The fluorescence evaluation of the early healing showed numerically better results for the nano-modified group; however this trend was not followed by the histomorphometric evaluation. A non-significant numerical superiority of the micro-rough group was observed in terms of vertical bone apposition, defect bone fill, bone-to-implant contact and bone density. In the intra-group analysis, the wider defects showed the worse results while the control sites showed the best results for the different parameters, but without statistical relevance. Conclusion Both surfaces may lead to complete fill of circumferential defects, but the gap width has to be considered as a challenge. The nano-scale modification was beneficial in the early stages of bone healing, but the micro-rough surface showed numerical better outcomes at the 8-week final period.
Resumo:
Aim: Primary and secondary stabilities of immediately loaded mandibular implants restored with fixed prostheses (FP) using rigid or semirigid splinting systems were clinically and radiographically evaluated. Methods: Fifteen edentulous patients were rehabilitated using hybrid FP; each had 5 implants placed between the mental foramens. Two groups were randomly divided: group 1-FP with the conventional rigid bar splinting the implants and group 2-semi-rigid cantilever extension system with titanium bars placed in the 2 distal abutment cylinders. Primary stability was evaluated using resonance frequency analysis after installation of the implant abutments. The measurements were made at 3 times: T0, at baseline; T1, 4 months after implant placement; and T2, 8 months after implant placement. Presence of mobility and inflammation in the implant surrounding regions were checked. Stability data were submitted to statistical analysis for comparison between groups (P, 0.05). Results: Implant survival rate for the implants was of 100% in both groups. No significant differences in the mean implant stability quotient values were found for both groups from baseline and after the 8-month follow-up. Conclusion: The immediate loading of the implants was satisfactory, and both splinting conditions (rigid and semi-rigid) can be successfully used for the restoration of edentulous mandibles. (Implant Dent 2012;21:486-490)
Resumo:
Autogenous bone grafts are considered to be the gold standard in bone regeneration because of their osteogenic activity; however, due to limited availability of intraoral donor sites and the need to resolve the demands of patients requires an alternative to these. Two male patients were submitted to implant surgery in two stages with 6 months intervals between each of them: the first was exodontia and placement of DBM graft into the socket; the second stage was the drill with a 2 mm internal diameter trephine in center of the alveolar ridge previously grafted with DBM and subsequent implant placement. The samples were analyzed under histological techniques. A very mature bone was observed at 6 months after DBM graft placement in the sockets, showing it to be a good alternative as bone graft.
Resumo:
Objectives: To investigate the effect of Si addition on a nanometer-scale roughness Ca and P implant surfaces in a canine tibia model by biomechanical and histomorphometric evaluations. Material and methods: The implant surfaces comprised a resorbable media CaP microblasted (control) and a CaP resorbable media + silica-boost microblasted (experimental) surfaces. Surfaces were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and optical interferometry (IFM) down to the nanometric level. The animal model involved the bilateral placement of control (n = 24) and experimental surface (n = 24) implants along the proximal tibiae of six dogs, remaining in vivo for 2 or 4 weeks. After euthanization, half of the specimens were torquedto- interface failure, and the other half was subjected to histomorphologic and bone-to-implant contact (BIC) evaluation. Torque and BIC statistical evaluation was performed by the Friedman test at 95% level of significance, and comparisons between groups was performed by the Dunn test. Results: IFM and SEM observations depicted comparable roughness parameters for both implant surfaces on the micrometer and nanometer scales. XPS analysis revealed similar chemical composition, except for the addition of Si on the experimental group. Torque-to-interface failure and BIC mean values showed no significant differences (P = 0.25 and 0.51, respectively) at both 2- and 4-week evaluation points for experimental and control groups. Early bone healing histomorphologic events were similar between groups. Conclusions: The experimental surface resulted in not significantly different biomechanical fixation and BIC relative to control. Both surfaces were biocompatible and osseoconductive.
Resumo:
Background: Accelerating bone healing around dental implants can reduce the long-term period between the insertion of implants and functional rehabilitation. Objective: This in vivo study evaluated the effect of a constant electromagnetic field (CEF) on bone healing around dental implants in dogs. Materials and methods: Eight dental implants were placed immediately after extraction of the first premolar and molar teeth on the mandible of two male dogs and divided into experimental (CEF) and control groups. A CEF at magnetic intensity of 0.8 mT with a pulse width of 25 mu s and frequency of 1.5 MHz was applied on the implants for 20 min per day for 2 weeks. Result and conclusion: After qualitative histological analysis, a small quantity of newly formed bone was observed in the gap between the implant surface and alveolar bone in both groups.
Resumo:
Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting groove design were divided in three groups: (1) non-fluted (no cutting groove, solid screw-form); (2) fluted (901 cut at the apex, tap design); and (3) Blossomt (Patent pending) (non-fluted with engineered trimmed thread design). The implants were screwed into polyurethane foam blocks and the insertion torque was recorded after each turn of 901 by a digital torque gauge. Controlled lateral loads of 10N followed by increments of 5 up to 100N were sequentially applied by a digital force gauge on a titanium abutment. Statistical comparison was performed with two-way mixed model ANOVA that evaluated implant design group, linear effects of turns and displacement loads, and their interaction. Results: While insertion torque increased as a function of number of turns for each design, the slope and final values increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- standard deviation [SD] = 64.1 +/- 26.8, 139.4 +/- 17.2, and 205.23 +/- 24.3 Ncm, respectively). While a linear relationship between horizontal displacement and lateral force was observed for each design, the slope and maximal displacement increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- SD 530 +/- 57.7, 585.9 +/- 82.4, and 782.33 +/- 269.4 mm, respectively). There was negligible to moderate levels of association between insertion torque and lateral displacement in the Blossomt, fluted and non-fluted design groups, respectively. Conclusion: Insertion torque was reduced in implant macrodesigns that incorporated cutting edges, and lesser insertion torque was generally associated with decreased micromovement. However, insertion torque and micromotion were unrelated within implant designs, particularly for those designs showing the least insertion torque.
Resumo:
Mini-implant insertion requires accurate surgical technique. This study shows an insertion technique using only tooth crown references; its scientific basis is evaluated radiographically. The sample consisted of 213 inter-radicular septa, evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width. The midpoint of the septum width was linked to the interdental contact point to determine septum midline. The distances from septum midline to "mesial and distal teeth were measured to evaluate the septum midline centralization degree in two different septum heights. The difference between mesial and distal distances represented the septum midline deviation degree. The mesial and distal distances were compared by t-tests, and the septum midline deviation was correlated with septum height using Pearson's correlation test. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. There was a moderate correlation (r = 0.45) between septum midline deviation and septum height. The tooth crown references evaluated on interproximal radiographs determine a high centralization degree of the septum midline on which the insertion site could be defined. The greater centralization degree was observed at the coronal septum area.
Resumo:
Objective: To evaluate the role of keratinized mucosa around dental implants, correlating with other clinical parameters related to the success of dental implants. Design: Cross-section. Setting: Institutional tertiary referral hospital. Patients: A total of 202 dental implants fixed in the cleft area of 109 patients with cleft lip and/or palate were evaluated. Interventions: The evaluated clinical parameters were probing depth and gingival and plaque indexes on the buccal surface (three sites). Main Outcome Measures: All clinical parameters were correlated with the width of keratinized mucosa around the implants. Results: The largest probing depths were detected when the width of keratinized mucosa was 2 mm or more, with a statistically significant difference between the means of the probing depth and keratinized mucosa width. Conclusion: Even though the present results suggest that peri-implant health can be observed in areas with keratinized mucosa width under 2 mm provided an adequate oral hygiene control is performed, longitudinal randomized studies are necessary to analyze the relationship between the width of keratinized mucosa and the health of peri-implant tissues.