Resumo:

Objective: To analyze the efficiency of high voltage pulsed current (HVPC) with early application in three different sites, in the regeneration of the sciatic nerve in rats submitted to crush injury, the sciatic functional index (SFI) was used to assess the functional recovery. Methods: After crushing of the nerve, 57 animals were submitted to cathodal HVPC at frequency of 50Hz and voltage of 100V, 20 minutes per day, 5 days per week. The rats were divided into five groups: control group; ganglion group; ganglion + muscle group; muscle group; and sham group. The SFI was determined weekly for seven weeks, from the preoperative period to the 6th postoperative week. Results: Compared with the control group, the results showed a significantly better performance of group 2 for the first 3 weeks; group 3 showed significantly better performance in the third week; and group 4 showed a significantly negative performance during the 481 and 6th weeks. Conclusion: Early application of HVPC had a positive effect in the treatment of the spinal cord region and the sciatic nerve root ganglion with a dispersive electrode on the contralateral lumbar region or on the gastrocnemius. However, HVPC had a negative effect in the treatment with an active electrode on the gastrocnemius and a dispersive electrode on the contralateral thigh. Level of evidence II, Prospective comparative study.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this paper, the combination of the Dynamic Threshold (DT) voltage technique with a non-planar structure is experimentally studied in triple-gate FinFETs. The drain current, transconductance, resistance, threshold voltage, subthreshold swing and Drain Induced Barrier Lowering (DIBL) will be analyzed in the DT mode and the standard biasing configuration. Moreover, for the first time, the important figures of merit for the analog performance such as transconductance-over-drain current, output conductance. Early voltage and intrinsic voltage gain will be studied experimentally and through three-dimensional (3-D) numerical simulations for different channel doping concentrations in triple-gate DTMOS FinFETs. The results indicate that the DTMOS FinFETs always yield superior characteristic; and larger transistor efficiency. In addition, DTMOS devices with a high channel doping concentration exhibit much better analog performance compared to the normal operation mode, which is desirable for high performance low-power/low-voltage applications. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work presents the analog performance of n-type triple-gate MuGFETs with high-k dielectrics and TiN gate material fabricated in 45 degrees rotated SOI substrates comparing their performance with standard MuGFETs fabricated without substrate rotation. Different fin widths are studied for temperatures ranging from 250 K up to 400 K. The results of transconductance, output conductance, transconductance over drain current ratio, intrinsic voltage gain and unit-gain frequency are studied. It is observed that the substrate rotation improves the carrier mobility of narrow MuGFETs at any temperature because of the changing in the conduction plane at the sidewalls from (1 1 0) to (1 0 0). For lower temperatures, the improvement of the carrier mobility of rotated MuGFETs is more noticeable as well as the rate of mobility improvement with the temperature decrease is larger. The output conductance is weakly affected by the substrate rotation. Although this improvement in the transconductance of rotated MuGFETs is negligibly transferred to the intrinsic voltage gain, the unity-gain frequency of rotated device is improved due to the larger carrier mobility in the entire range of temperatures studied. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We describe the planning, implementation, and initial results of the first planned move of the default position of spectra on the Hubble Space Telescope's Cosmic Origins Spectrograph (COS) Far Ultraviolet (FUV) cross-delay line detector. This was motivated by the limited amount of charge that can be extracted from the microchannel plate due to gain sag at any one position. Operations at a new location began on July 23, 2012, with a shift of the spectrum by +3.5"(corresponding to ~ 41 pixels or ~ 1 mm) in a direction orthogonal to the spectral dispersion. Operation at this second "lifetime position" allows for spectra to be collected which are not affected by detector artifacts and loss of sensitivity due to gain sag. We discuss programs designed to enable operations at the new lifetime position; these include determinations of operational high voltage, measuring walk corrections and focus, confirming spectrum placement and aperture centering, and target acquisition performance. We also present results related to calibration of the new lifetime position, including measurements of spectral resolution and wavelength calibration, flux and flat field calibration, carryover of time-dependent sensitivity monitoring, and operations with the Bright Object Aperture (BOA).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ion implantation of metal species into insulators provides a tool for the formation of thin, electrically conducting, surface layers with experimenter-controlled resistivity. High energy implantation of Pt and Ti into alumina accelerator components has been successfully employed to control high voltage surface breakdown in a number of cases. In the work described here we have carried out some basic investigations related to the origin of this phenomenon. By comparison of the results of alumina implanted with Ti at 75 keV with the results of prior investigations of polymers implanted with Pt at 49 eV and Au at 67 eV, we describe a physical model of the effect based on percolation theory and estimate the percolation parameters for the Ti-alumina composite. We estimate that the percolation dose threshold is about 4 x 10(16) cm(-2) and the maximum dose for which the system remains an insulator-conductor composite is about 10 x 10(16) cm(-2). The saturation electrical conductivity is estimated to be about 50 S/m. We conclude that the observed electrical conductivity properties of Ti-implanted alumina can be satisfactorily described by percolation theory. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3697900]

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In recent years, there was an increase of ancillary service loads, such as signaling systems, inspection robots, surveillance cameras, and other monitoring devices distributed along high-voltage transmission lines which require low-power dc voltage supplies. This paper investigates the use of the induced voltage in the shield wires of an overhead 525 kV transmission line as a primary power source. Since phase current variations throughout the day affect the induced voltage in the overhead ground wire, a step-down dc-dc converter is used after rectification of the ac voltage to provide a regulated dc output voltage. The initial encouraging results obtained indicate that this form of power supply can be a feasible and cost-effective alternative for feeding small ancillary service loads. The simulation results are validated by field measurements as well as the installation of a 200 W voltage stabilization system prototype.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, the impact of global and/or local strain engineering techniques on tri-gate p- and nMuGFETs performance is experimentally evaluated. Multiple gate structures were analyzed through basic and analog performance parameters for four different splits processed with different strain-engineering techniques (unstrained, uniaxial, biaxial and uniaxial+biaxial stress). While n-channel devices with narrow fins present a worse analog behavior, biaxial stress promotes the electron mobility for larger devices increasing the voltage gain. Besides the voltage gain, the transconductance, output conductance and Early Voltage are also evaluated. Although pMuGFETs are less affected by the strain engineering, they present better analog behavior for all studied devices.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a technique for performing analog design synthesis at circuit level providing feedback to the designer through the exploration of the Pareto frontier. A modified simulated annealing which is able to perform crossover with past anchor points when a local minimum is found which is used as the optimization algorithm on the initial synthesis procedure. After all specifications are met, the algorithm searches for the extreme points of the Pareto frontier in order to obtain a non-exhaustive exploration of the Pareto front. Finally, multi-objective particle swarm optimization is used to spread the results and to find a more accurate frontier. Piecewise linear functions are used as single-objective cost functions to produce a smooth and equal convergence of all measurements to the desired specifications during the composition of the aggregate objective function. To verify the presented technique two circuits were designed, which are: a Miller amplifier with 96 dB Voltage gain, 15.48 MHz unity gain frequency, slew rate of 19.2 V/mu s with a current supply of 385.15 mu A, and a complementary folded cascode with 104.25 dB Voltage gain, 18.15 MHz of unity gain frequency and a slew rate of 13.370 MV/mu s. These circuits were synthesized using a 0.35 mu m technology. The results show that the method provides a fast approach for good solutions using the modified SA and further good Pareto front exploration through its connection to the particle swarm optimization algorithm.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o efeito da corrente catódica de alta voltagem sobre a dor em um modelo experimental de ciatalgia. MÉTODOS: Foram utilizados 16 ratos Wistar, machos, submetidos a um modelo de ciatalgia experimental no membro pélvico direito. Os sujeitos foram divididos em grupo simulacro (GS) e grupo tratado com corrente catódica (GP-) por 20 min diários durante 10 dias. O modelo de compressão foi realizado com amarria por fio catgut 4.0 cromado, em quatro pontos ao longo do nervo isquiático. A avaliação da nocicepção foi realizada, de forma funcional, com o tempo de elevação da pata (TEP), e à pressão, pelo limiar de retirada, via analgesímetro eletrônico. Os dados foram coletados antes do modelo de ciatalgia (AV1), três dias depois da compressão (antes, AV2, e após o tratamento, AV3), após o quinto dia de tratamento (AV4) e em seguida ao décimo dia de tratamento (AV5). RESULTADOS: Pela avaliação funcional, em ambos os grupos houve aumento da nocicepção, sem redução da mesma em qualquer momento da avaliação. À pressão, no entanto, o GS mostrou redução do limiar de retirada em todos os momentos, enquanto o GP- apresentou redução do limiar apenas inicialmente - em AV5 o limiar foi restaurado. CONCLUSÃO: Não houve alteração na nocicepção pela avaliação funcional; porém, à pressão, o tratamento com corrente catódica mostrou efeito com a somatória de terapias.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Analisar a eficiência do tratamento com a estimulação elétrica de alta voltagem (EEAV) em três diferentes locais, aplicada precocemente na regeneração do nervo ciático submetido à lesão por esmagamento, e avaliada através do índice funcional do ciático (IFC), em ratos. MÉTODO: Após o esmagamento, 57 ratos foram submetidos à EEAV catódica nos parâmetros: frequência de 50Hz, 100V de tensão, 20 minutos diários, 5 dias por semana. Os ratos foram divididos aleatoriamente em: grupo controle; grupo gânglio; grupo gânglio + músculo; grupo músculo e; grupo simulado. O IFC foi avaliado semanalmente durante sete semanas, partindo do pré-operatório até a 6ª semana pós-operatória. RESULTADOS: Em comparação ao grupo controle, os resultados mostraram desempenho significativamente superior do grupo gânglio nas três primeiras semanas, e do grupo gânglio + músculo na 3ª semana, enquanto o grupo músculo teve desempenho significativamente negativo na 4ª e 6ª semanas. CONCLUSÃO: a EEAV aplicada precocemente, foi positiva no tratamento da região da medula e gânglio da raiz nervosa do ciático com o eletrodo dispersivo na região lombar contralateral ou no músculo gastrocnêmio. Porém, proporcionou efeitos negativos no tratamento com eletrodo ativo no músculo gastrocnêmio e dispersivo na coxa contralateral. Nível de evidência II, Estudo prospectivo comparativo.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents the results of research aiming to develop partial discharge detection techniques in high voltage equipment, at substation environment. Measurements of high frequency components of leakage current, at equipments' grounding conductor, were performed. This procedure was performed with the equipment energized and without disconnecting it from the system. The partial discharge generated current pulse is picked up by a high frequency CT, and is detected by an oscilloscope. The partial discharge identification was made considering previously obtained laboratory results, where partial discharges were characterized by means of its time domain signatures. This paper focuses measurements in SF6 circuit breakers. Encouraging results were obtained, showing the feasibility of detecting partial discharges in energized equipment in the laboratory and in the field, in a substation environment, using this method.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Doppler Broadening Spectroscopy of the large Ge crystal of an HPGe detector was perforrned using positrons from pair production of 6.13 MeV ϒ-rays from the 19F(p,αϒ) 16O reaction. Two HPGe detectors facing opposite sides of the Ge crystal acting as target provided both coincidence and singles spectra. Changes in the shape of the annihilation peak were observed when the high voltage applied to the target detector was switched on or off, amounting to somewhat less than 20% when the areas of equivalent energy intervals in the corresponding normalized spectra are compared.