12 resultados para High voltage

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To analyze the efficiency of high voltage pulsed current (HVPC) with early application in three different sites, in the regeneration of the sciatic nerve in rats submitted to crush injury, the sciatic functional index (SFI) was used to assess the functional recovery. Methods: After crushing of the nerve, 57 animals were submitted to cathodal HVPC at frequency of 50Hz and voltage of 100V, 20 minutes per day, 5 days per week. The rats were divided into five groups: control group; ganglion group; ganglion + muscle group; muscle group; and sham group. The SFI was determined weekly for seven weeks, from the preoperative period to the 6th postoperative week. Results: Compared with the control group, the results showed a significantly better performance of group 2 for the first 3 weeks; group 3 showed significantly better performance in the third week; and group 4 showed a significantly negative performance during the 481 and 6th weeks. Conclusion: Early application of HVPC had a positive effect in the treatment of the spinal cord region and the sciatic nerve root ganglion with a dispersive electrode on the contralateral lumbar region or on the gastrocnemius. However, HVPC had a negative effect in the treatment with an active electrode on the gastrocnemius and a dispersive electrode on the contralateral thigh. Level of evidence II, Prospective comparative study.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ion implantation of metal species into insulators provides a tool for the formation of thin, electrically conducting, surface layers with experimenter-controlled resistivity. High energy implantation of Pt and Ti into alumina accelerator components has been successfully employed to control high voltage surface breakdown in a number of cases. In the work described here we have carried out some basic investigations related to the origin of this phenomenon. By comparison of the results of alumina implanted with Ti at 75 keV with the results of prior investigations of polymers implanted with Pt at 49 eV and Au at 67 eV, we describe a physical model of the effect based on percolation theory and estimate the percolation parameters for the Ti-alumina composite. We estimate that the percolation dose threshold is about 4 x 10(16) cm(-2) and the maximum dose for which the system remains an insulator-conductor composite is about 10 x 10(16) cm(-2). The saturation electrical conductivity is estimated to be about 50 S/m. We conclude that the observed electrical conductivity properties of Ti-implanted alumina can be satisfactorily described by percolation theory. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3697900]

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In recent years, there was an increase of ancillary service loads, such as signaling systems, inspection robots, surveillance cameras, and other monitoring devices distributed along high-voltage transmission lines which require low-power dc voltage supplies. This paper investigates the use of the induced voltage in the shield wires of an overhead 525 kV transmission line as a primary power source. Since phase current variations throughout the day affect the induced voltage in the overhead ground wire, a step-down dc-dc converter is used after rectification of the ac voltage to provide a regulated dc output voltage. The initial encouraging results obtained indicate that this form of power supply can be a feasible and cost-effective alternative for feeding small ancillary service loads. The simulation results are validated by field measurements as well as the installation of a 200 W voltage stabilization system prototype.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o efeito da corrente catódica de alta voltagem sobre a dor em um modelo experimental de ciatalgia. MÉTODOS: Foram utilizados 16 ratos Wistar, machos, submetidos a um modelo de ciatalgia experimental no membro pélvico direito. Os sujeitos foram divididos em grupo simulacro (GS) e grupo tratado com corrente catódica (GP-) por 20 min diários durante 10 dias. O modelo de compressão foi realizado com amarria por fio catgut 4.0 cromado, em quatro pontos ao longo do nervo isquiático. A avaliação da nocicepção foi realizada, de forma funcional, com o tempo de elevação da pata (TEP), e à pressão, pelo limiar de retirada, via analgesímetro eletrônico. Os dados foram coletados antes do modelo de ciatalgia (AV1), três dias depois da compressão (antes, AV2, e após o tratamento, AV3), após o quinto dia de tratamento (AV4) e em seguida ao décimo dia de tratamento (AV5). RESULTADOS: Pela avaliação funcional, em ambos os grupos houve aumento da nocicepção, sem redução da mesma em qualquer momento da avaliação. À pressão, no entanto, o GS mostrou redução do limiar de retirada em todos os momentos, enquanto o GP- apresentou redução do limiar apenas inicialmente - em AV5 o limiar foi restaurado. CONCLUSÃO: Não houve alteração na nocicepção pela avaliação funcional; porém, à pressão, o tratamento com corrente catódica mostrou efeito com a somatória de terapias.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Analisar a eficiência do tratamento com a estimulação elétrica de alta voltagem (EEAV) em três diferentes locais, aplicada precocemente na regeneração do nervo ciático submetido à lesão por esmagamento, e avaliada através do índice funcional do ciático (IFC), em ratos. MÉTODO: Após o esmagamento, 57 ratos foram submetidos à EEAV catódica nos parâmetros: frequência de 50Hz, 100V de tensão, 20 minutos diários, 5 dias por semana. Os ratos foram divididos aleatoriamente em: grupo controle; grupo gânglio; grupo gânglio + músculo; grupo músculo e; grupo simulado. O IFC foi avaliado semanalmente durante sete semanas, partindo do pré-operatório até a 6ª semana pós-operatória. RESULTADOS: Em comparação ao grupo controle, os resultados mostraram desempenho significativamente superior do grupo gânglio nas três primeiras semanas, e do grupo gânglio + músculo na 3ª semana, enquanto o grupo músculo teve desempenho significativamente negativo na 4ª e 6ª semanas. CONCLUSÃO: a EEAV aplicada precocemente, foi positiva no tratamento da região da medula e gânglio da raiz nervosa do ciático com o eletrodo dispersivo na região lombar contralateral ou no músculo gastrocnêmio. Porém, proporcionou efeitos negativos no tratamento com eletrodo ativo no músculo gastrocnêmio e dispersivo na coxa contralateral. Nível de evidência II, Estudo prospectivo comparativo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We describe the planning, implementation, and initial results of the first planned move of the default position of spectra on the Hubble Space Telescope's Cosmic Origins Spectrograph (COS) Far Ultraviolet (FUV) cross-delay line detector. This was motivated by the limited amount of charge that can be extracted from the microchannel plate due to gain sag at any one position. Operations at a new location began on July 23, 2012, with a shift of the spectrum by +3.5"(corresponding to ~ 41 pixels or ~ 1 mm) in a direction orthogonal to the spectral dispersion. Operation at this second "lifetime position" allows for spectra to be collected which are not affected by detector artifacts and loss of sensitivity due to gain sag. We discuss programs designed to enable operations at the new lifetime position; these include determinations of operational high voltage, measuring walk corrections and focus, confirming spectrum placement and aperture centering, and target acquisition performance. We also present results related to calibration of the new lifetime position, including measurements of spectral resolution and wavelength calibration, flux and flat field calibration, carryover of time-dependent sensitivity monitoring, and operations with the Bright Object Aperture (BOA).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents the results of research aiming to develop partial discharge detection techniques in high voltage equipment, at substation environment. Measurements of high frequency components of leakage current, at equipments' grounding conductor, were performed. This procedure was performed with the equipment energized and without disconnecting it from the system. The partial discharge generated current pulse is picked up by a high frequency CT, and is detected by an oscilloscope. The partial discharge identification was made considering previously obtained laboratory results, where partial discharges were characterized by means of its time domain signatures. This paper focuses measurements in SF6 circuit breakers. Encouraging results were obtained, showing the feasibility of detecting partial discharges in energized equipment in the laboratory and in the field, in a substation environment, using this method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Doppler Broadening Spectroscopy of the large Ge crystal of an HPGe detector was perforrned using positrons from pair production of 6.13 MeV ϒ-rays from the 19F(p,αϒ) 16O reaction. Two HPGe detectors facing opposite sides of the Ge crystal acting as target provided both coincidence and singles spectra. Changes in the shape of the annihilation peak were observed when the high voltage applied to the target detector was switched on or off, amounting to somewhat less than 20% when the areas of equivalent energy intervals in the corresponding normalized spectra are compared.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a CMOS implementation of a linear voltage regulator (LVR) used to power up implanted physiological signal systems, as it is the case of a wireless blood pressure biosensor. The topology is based on a classical structure of a linear low-dropout regulator. The circuit is powered up from an RF link, thus characterizing a passive radio frequency identification (RFID) tag. The LVR was designed to meet important features such as low power consumption and small silicon area, without the need for any external discrete components. The low power operation represents an essential condition to avoid a high-energy RF link, thus minimizing the transmitted power and therefore minimizing the thermal effects on the patient's tissues. The project was implemented in a 0.35-mu m CMOS process, and the prototypes were tested to validate the overall performance. The LVR output is regulated at 1 V and supplies a maximum load current of 0.5 mA at 37 degrees C. The load regulation is 13 mV/mA, and the line regulation is 39 mV/V. The LVR total power consumption is 1.2 mW.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we have studied the radiation effects on MOSFET electronic devices. The integrated circuits were exposed to 10 key X-ray radiation and 2.6 MeV energy proton beam. We have irradiated MOSFET devices with two different geometries: rectangular-gate transistor and circular-gate transistor. We have observed the cumulative dose provokes shifts on the threshold voltage and increases or decreases the transistor's off-state and leakage current. The position of the trapped charges in modern CMOS technology devices depends on radiation type, dose rate, total dose, applied bias and is a function of device geometry. We concluded the circular-gate transistor is more tolerant to radiation than the rectangular-gate transistor. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In a homemade UV-Ozone generator, different ignition tubes extracted from HID mercury vapor lamps were investigated, namely: 80, 125, 250 and 400 watts. The performance of the generator in function of the type of the ignition lamp was monitored by the measurements of the ozone concentration and the temperature increment. The results have shown that the 400 W set up presented the highest ozone production, which was used in the treatment of indium tin oxide (ITO) films. Polymer light emitting diodes were assembled using ITO films, treated for 10, 20 and 30 min, as an anode. The overall results indicate improvement of the threshold voltage (reduction) and electroluminescence of these devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The complexity of power systems has increased in recent years due to the operation of existing transmission lines closer to their limits, using flexible AC transmission system (FACTS) devices, and also due to the increased penetration of new types of generators that have more intermittent characteristics and lower inertial response, such as wind generators. This changing nature of a power system has considerable effect on its dynamic behaviors resulting in power swings, dynamic interactions between different power system devices, and less synchronized coupling. This paper presents some analyses of this changing nature of power systems and their dynamic behaviors to identify critical issues that limit the large-scale integration of wind generators and FACTS devices. In addition, this paper addresses some general concerns toward high compensations in different grid topologies. The studies in this paper are conducted on the New England and New York power system model under both small and large disturbances. From the analyses, it can be concluded that high compensation can reduce the security limits under certain operating conditions, and the modes related to operating slip and shaft stiffness are critical as they may limit the large-scale integration of wind generation.