20 resultados para Forces de compression

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

40.00% 40.00%

Publicador:

Resumo:

There is no reason for Dentistry to use different terms for phenomena defined in Physics, the specific field in which concepts associated with forces are established and adapted. In place of pressure/tension, the compression/traction pair should be used. This study defines each one of these terms and justifies their use. Our contemporary world demands standardized criteria, methods, measures, concepts and terms to ensure that study protocols, results and applications are used in the same way in any country or area of human action.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The centrifuge technique was used to investigate the influence of particle size, applied compression, and substrate material (stainless steel, glass, Teflon, and poly(vinyl chloride)) on particle-surface adhesion force. For this purpose, phosphatic rock (rho(p) = 3090 kg/m(3)) and manioc starch particles (rho(p) = 1480 kg/m(3)) were used as test particles. A microcentrifuge that reached a maximum rotation speed of 14 000 rpm and which contained specially designed centrifuge tubes was used in the adhesion force measurements. The curves showed that the adhesion force profile followed a normal log distribution. The adhesion force increased linearly with particle size and with the increase of each increment of compression force. The manioc starch particles presented greater adhesion forces than the phosphatic rock particles for all particle sizes studied. The glass substrate showed a higher adherence than the other materials, probably due to its smoother topographic surface roughness in relation to the other substrata.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During orthodontic tooth movement (OTM), alveolar bone is resorbed by osteoclasts in compression sites (CS) and is deposited by osteoblasts in tension sites (TS). The aim of this study was to develop a standardized OTM protocol in mice and to investigate the expression of bone resorption and deposition markers in CS and TS. An orthodontic appliance was placed in C57BL6/J mice. To define the ideal orthodontic force, the molars of the mice were subjected to forces of 0.1 N, 0.25 N, 0.35 N and 0.5 N. The expression of mediators that are involved in bone remodeling at CS and TS was analyzed using a Real-Time PCR. The data revealed that a force of 0.35 N promoted optimal OTM and osteoclast recruitment without root resorption. The levels of TNF-alpha, RANKL, MMP13 and OPG were all altered in CS and TS. Whereas TNF-a and Cathepsin K exhibited elevated levels in CS. RUNX2 and OCN levels were higher in TS. Our results suggest that 0.35 N is the ideal force for OTM in mice and has no side effects. Moreover, the expression of bone remodeling markers differed between the compression and the tension areas, potentially explaining the distinct cellular migration and differentiation patterns in each of these sites. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyze the shear forces on the vertebral body L4 when submitted to a compression force by means of transmission photoelasticity. Methods: Twelve photoelastic models were divided into three groups, with four models per group, according to the positioning of the sagittal section vertebrae L4-L5 (sections A, B and C). The simulation was performed using a 15N compression force, and the fringe orders were evaluated in the vertebral body L4 by the Tardy compensation method. Results: Photoelastic analysis showed, in general, a homogeneous distribution in the vertebral bodies. The shear forces were higher in section C than B, and higher in B than A. Conclusion: The posterior area of L4, mainly in section C, showed higher shear concentrations, corresponding to a more susceptible area for bone fracture and spondylolisthesis. Economic and Decision Analyses Development of an Economic or Decision Model. Level I

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study evaluated the influence of the cavity configuration factor ("C-Factor") and light activation technique on polymerization contraction forces of a Bis-GMA-based composite resin (Charisma, Heraeus Kulzer). Material and Methods: Three different pairs of steel moving bases were connected to a universal testing machine (Emic DL 500): groups A and B - 2x2 mm (CF=0.33), groups C and D - 3x2 mm (CF=0.66), groups E and F - 6x2 mm (CF=1.5). After adjustment of the height between the pair of bases so that the resin had a volume of 12 mm(3) in all groups, the material was inserted and polymerized by two different methods: pulse delay (100 mW/cm(2) for 5 s, 40 s interval, 600 mW/cm(2) for 20 s) and continuous pulse (600 mW/cm(2) for 20 s). Each configuration was light cured with both techniques. Tensions generated during polymerization were recorded by 120 s. The values were expressed in curves (Force(N) x Time(s)) and averages compared by statistical analysis (ANOVA and Tukey's test, p<0.05). Results: For the 2x2 and 3x2 bases, with a reduced C-Factor, significant differences were found between the light curing methods. For 6x2 base, with high C-Factor, the light curing method did not influence the contraction forces of the composite resin. Conclusions: Pulse delay technique can determine less stress on tooth/restoration interface of adhesive restorations only when a reduced C-Factor is present.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twelve participants ran (9 km . h(-1)) to test two types of running shoes: replica and original shoes. Ground reaction force, plantar pressure and electromyographic activity were recorded. The shoes were tested randomly and on different days. Comparisons between the two experimental conditions were made by analysis of variance (ANOVA) test (P <= 0.05). The time to first peak, loading rate of the first peak and impulse of the first 75 ms of stance were significantly different between the shoes (P <= 0.05), revealing an increase of impact forces for the replica shoes. The peak plantar pressure values were significantly higher (P <= 0.05) when wearing replica shoes. During running, the contact area was significantly smaller (P <= 0.05) for the replica shoe. The electromyographic activity of the analysed muscles did not show changes between the two shoes in running. These findings suggest that the use of replica running shoes can increase the external load applied to the human body, but may not change the muscle activity pattern during locomotion. This new mechanical situation may increase the risk of injuries in these movements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unstable shoes have been designed to promote "natural instability" and during walking they should simulate barefoot gait, enhancing muscle activity and, thus, attributing an advantage over regular tennis shoes. Recent studies showed that, after special training on the appropriate walking pattern, the use of the Masai Barefoot Technology (MBT) shoe increases muscle activation during walking. Our study presents a comparison of muscle activity as well as horizontal and vertical forces during gait with the MBT, a standard tennis shoe and barefoot walking of healthy individuals without previous training. These variables were compared in 25 female subjects and gait conditions were compared using ANOVA repeated measures (effect size:0.25). Walking with the MBT shoe in this non-instructed condition produced higher vertical forces (first vertical peak and weight acceptance rate) than walking with a standard shoe or walking barefoot, which suggests an increase in the loads received by the musculoskeletal system, especially at heel strike. Walking with the MBT shoe did not increase muscle activity when compared to walking with the standard shoe. The barefoot condition was more effective than the MBT shoe at enhancing muscle activation. Therefore, in healthy individuals, no advantage was found in using the MBT over a standard tennis shoe without a special training period. Further studies using the MBT without any instruction over a longer period are needed to evaluate if the higher loads observed in the present study would return to their baseline values after a period of adaptation, and if the muscle activity would increase over time. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The neutron-rich lead isotopes, up to Pb-216, have been studied for the first time, exploiting the fragmentation of a primary uranium beam at the FRS-RISING setup at GSI. The observed isomeric states exhibit electromagnetic transition strengths which deviate from state-of-the-art shell-model calculations. It is shown that their complete description demands the introduction of effective three-body interactions and two-body transition operators in the conventional neutron valence space beyond Pb-208.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When a cylinder is connected to an abutment it is expected that abutment and cylinder will be subjected to compression forces throughout their periphery because of the clamping force exerted by the screw. The deformation resultant of this compression should be measurable and uniform along the periphery of the abutment. Considering that multiple retainers connected to each other can affect the fit of a framework, as well as the use of different alloys, it is expected that the abutments will present different levels of deformation as a result of framework connection. The aim of this study was to evaluate the deformation of implant abutments after frameworks, cast either in cobalt-chromium (CoCr) or silver-palladium (AgPd) alloys, were connected. Samples (n = 5) simulating a typical mandibular cantilevered implant-supported prosthesis framework were fabricated in cobalt-chromium and silver-palladium alloys and screwed onto standard abutments positioned on a master-cast containing 5 implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation as the retention screws were tightened. A combination of compressive and tensile forces was observed on the abutments for both CoCr and AgPd frameworks. There was no evidence of significant differences in median abutment deformation levels for 9 of the 10 abutment aspects. Visually well-fit frameworks do not necessarily transmit load uniformly to abutments. The use of CoCr alloy for implant-supported prostheses frameworks may be as clinically acceptable as AgPd alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Chyle fistulas may occur after left neck dissections that include level IV, due to injury of the thoracic duct or of 1 of its major branches. Despite being unusual, this complication carries substantial postoperative morbidity and even mortality. So far, no effective intraoperative maneuver has been reported to detect this fistula at the end of a neck dissection. In this cohort study, we sought to describe a simple new maneuver, intraoperative abdominal compression, which can effectively help to identify an open major lymphatic duct on level IV at the end of a neck dissection. Patients and Methods From March 1989 to September 2010, 206 patients underwent neck dissections involving left level IV, and underwent intraoperative abdominal compression. There were 119 men and 87 women, with ages ranging from 18 to 81 years (median, 52 years). One hundred forty-four patients had squamous cell carcinomas, 54 had thyroid carcinomas, 5 had malignant melanomas, and 3 had salivary cancers. Distribution by type of left neck dissection was: selective including levels II, III, and IV (73 cases; 35.4%), selective including levels II, III, IV, and V (55 cases; 26.6%), selective including levels I, II, III, and IV (12 cases; 5.8%), modified radical (47 cases; 22.8%), and radical (19 cases; 9.2%). In all cases, at the end of the procedure, the endotracheal tube was temporarily disconnected from the ventilator. Keeping the dissected level IV area under clear visualization, an abdominal compression was performed. At this moment, any detected lymphatic leak was carefully clamped and tied with nonabsorbable sutures. After ventilating the patient, the intraoperative abdominal compression was repeated to reassure complete occlusion of the lymphatic vessel. Results In 13 cases (6.3%), a chyle leak was detected after performing the intraoperative abdominal compression. All leaks except for 2 were successfully controlled after 1 attempt. In these 2 patients, a patch of muscle and fat tissue was applied with fibrin glue on the top. In 1 of these patients, another chyle leak in a different location was detected only at the second intraoperative abdominal compression, and was also effectively closed. Postoperatively, there were 2 (1%) chyle fistulas, both among these 13 cases, and all were successfully managed with clinical measures only. No fistulas occurred among the remaining 193 patients in whom intraoperative abdominal compression did not demonstrate lymphatic leak. Conclusion To our knowledge, this is the first description of a specific maneuver to actively detect a lymphatic fistula at the end of a left neck dissection involving level IV. In this study, intraoperative abdominal compression was able to detect an open lymphatic vessel in 6.3% of the cases, as well as to assure its effective sealing in the remaining 93.7% of the patients. Moreover, no life-threatening high-volume fistula was noted in this study. (C) 2012 Wiley Periodicals, Inc. Head Neck, 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the measurements of both vertical and lateral levitation forces between a permanent magnet NdFeB and a polycrystalline YBa4Cu6O7-delta superconductor. The analysis of the obtained results revealed an interesting correlation between the behavior of the forces in the field-cooled and zero-field-cooled regimes, resembling the structure of the so-called susceptibility spectrum chi ''(chi'). Such force-force diagrams can be useful for identifying flux distribution structure inside a superconducting material. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4743006]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The reduction of the pelvic floor muscles (PFM) strength is a major cause of stress urinary incontinence (SUI). Objective: To compare active and passive forces, and vaginal cavity aperture in continent and stress urinary incontinent women. Method: The study included a total of thirty-two women, sixteen continent women (group 1 - G1) and sixteen women with SUI (group 2 - G2). To evaluate PFM passive and active forces in anteroposterior (sagittal plane) and left-right directions (frontal plane) a stainless steel specular dynamometer was used. Results: The anteroposterior active strength for the continent women (mean +/- standard deviation) (0.3 +/- 0.2 N) was greater compared to the values found in the evaluation of incontinent women (0.1 +/- 0.1 N). The left-right active strength (G1=0.43 +/- 0.1 N; G2=0.40 +/- 0.1 N), the passive force (G1=1.1 +/- 0.2 N; G2=1.1 +/- 0.3 N) and the vaginal cavity aperture (G1=21 +/- 3 mm; G2=24 +/- 4 mm) did not differ between groups 1 and 2. Conclusion: The function evaluation of PFM showed that women with SUI had a lower anteroposterior active strength compared to continent women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the canonical equilibrium of systems with long-range forces in competition. These forces create a modulation in the interaction potential and modulated phases appear at the system scale. The structure of these phases differentiate this system from monotonic potentials, where only the mean-field and disordered phases exist. With increasing temperature, the system switches from one ordered phase to another through a first-order phase transition. Both mean-field and modulated phases may be stable, even at zero temperature, and the long-range nature of the interaction will lead to metastability characterized by extremely long time scales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. The aim of this study was to evaluate whether an association of elastic stockings and walking for a short period in the late afternoon reduces leg edema. Methods. Volume changes of the legs of sixteen patients (32 limbs), who walked on a treadmill for 30 minutes using elastic compression stockings, were analyzed in a quantitative, cross-over randomized (in order of arrival at the clinic) study. They were submitted to volumetry using the water displacement technique and subsequently required to put on 20/30 made-to-measure compression stockings (Sigvaris). The patients walked on a treadmill for 30 minutes and after removing the stockings volumetry of the legs was again performed. Legs were assessed using the CEAP classification and divided into groups. Analysis of variance was used for statistical analysis with an alpha error of 5% being considered acceptable. Results. When participants walked wearing compression stockings, there was a reduction in leg volume. When the CEAP classification was evaluated, it was noted that there was a statistically significant difference for the CEAP C0, C1 and C2 categories of legs using stockings compared to those that did not use. Conclusion. Compression stockings have a synergistic effect with walking in the late afternoon thus reducing edema of the lower limbs. [Int Angiol 2012;31:490-3]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To evaluate the ability of multifocal transient pattern electroretinography (mfPERG) to detect neural loss and assess the relationship between mfPERG and visual-field (VF) loss in eyes with chiasmal compression. Methods 23 eyes from 23 patients with temporal VF defects and band atrophy of the optic nerve and 21 controls underwent standard automated perimetry and mfPERG using a stimulus pattern of 19 rectangles, each consisting of 12 squares. The response was determined for the central rectangle, for the nasal and temporal hemifields (eight rectangles each) and for each quadrant (three rectangles) in both patients and controls. Comparisons were made using variance analysis. Correlations between VF and mfPERG measurements were verified by linear regression analysis. Results Mean +/- SD mfPERG amplitudes from the temporal hemifield (0.50 +/- 0.17 and 0.62 +/- 0.32) and temporal quadrants (superior 0.42 +/- 0.21 and 0.52 +/- 0.35, inferior 0.51 +/- 0.23 and 0.74 +/- 0.40) were significantly lower in eyes with band atrophy than in controls (0.78 +/- 0.24, 0.89 +/- 0.28, 0.73 +/- 60.26, 0.96 +/- 0.36, 0.79 +/- 0.26 and 0.91 +/- 0.31, respectively). No significant difference was observed in nasal hemifield measurements. Significant correlations (0.36-0.73) were found between VF relative sensitivity and mfPERG amplitude in different VF sectors. Conclusions mfPERG amplitude measurements clearly differentiate eyes with temporal VF defect from controls. The good correlation between mfPERG amplitudes and the severity of VF defect suggests that mfPERG may be used as an indicator of ganglion cell dysfunction.