6 resultados para Flexibilidade - Flexibility
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
This study investigated the acute effect of static stretching exercises (SSE) on maximum strength (MS) and strength endurance (SE) performance in lower and upper limbs. Thirteen volunteers participated in the study and were submitted to MS and SE (70% 1RM) tests in the bench press and squat exercises with or without SSE. The paired T test showed that the SSE decreased MS in the squat (141.2 +/- 34.2 vs 132 +/- 34.9kg, p=0.007) and in the BP (77.5 +/- 21.7 vs 71.7 +/- 17.7kg p=0.04). Squat SE was not affected by SSE (16.2 +/- 5.7 vs 16.3 +/- 6.8 repetitions p=0.48). On the other hand, bench press SE decreased significantly after SSE (11.7 +/- 4.8 vs 9.9 +/- 5.1 repetitions p=0.008). Therefore, SSE impaired MS performance on upper and lower limbs but SE was affected only on upper limbs. This difference in SE may be related to the stretching exercises volume applied to the size of each muscle group.
Resumo:
Over the last few years, Business Process Management (BPM) has achieved increasing popularity and dissemination. An analysis of the underlying assumptions of BPM shows that it pursues two apparently contradicting goals: on the one hand it aims at formalising work practices into business process models; on the other hand, it intends to confer flexibility to the organization - i.e. to maintain its ability to respond to new and unforeseen situations. This paper analyses the relationship between formalisation and flexibility in business process modelling by means of an empirical case study of a BPM project in an aircraft maintenance company. A qualitative approach is adopted based on the Actor-Network Theory. The paper offers two major contributions: (a) it illustrates the sociotechnical complexity involved in BPM initiatives; (b) it points towards a multidimensional understanding of the relation between formalization and flexibility in BPM projects.
Resumo:
Este artigo apresenta um modelo de cadeia de valor da saúde que representa, de maneira esquemática, o sistema de saúde do Brasil. O modelo proposto tem como intuito apresentar uma adequação à realidade brasileira, bem como abrangência e flexibilidade para utilização em atividades acadêmicas e análises do setor de saúde do Brasil. O modelo coloca ênfase em três componentes: principais atividades dessa cadeia, agrupadas em elos verticais e horizontais; missão de cada um desses elos; e principais fluxos da cadeia. A cadeia proposta é formada por seis elos verticais e três horizontais, perfazendo um total de nove: desenvolvimento de conhecimento em saúde; fornecimento de produtos e tecnologias; serviços de saúde; intermediação financeira; financiamento da saúde; consumo de saúde; regulação; distribuição de produtos de saúde; e serviços de apoio e complementares. A análise da cadeia proposta pode ser realizada por meio de quatro fluxos: inovação e conhecimento; produtos e serviços; financeiro; e de informação.
Resumo:
Introduction: The aim of this study was to assess the effect of nitrogen ion implantation on the flexibility of rotary nickel-titanium (NiTi) instruments as measured by the load required to bend implanted and nonimplanted instruments at a 30 degrees angle. Methods: Thirty K3 files, size #40, 0.02 taper and 25-mm length, were allocated into 2 groups as follows: group A, 15 files exposed to nitrogen ion implantation at a dose of 2.5 x 10(17) ions/cm(2), voltage 200 KeV, current density 1 mu A/cm(2), temperature 130 degrees C, and vacuum conditions of 10 x 10(-6) mm Hg for 6 hours; and group B, 15 nonimplanted files. One extra file was used for process control. All instruments were subjected to bend testing on a modified troptometer, with measurement of the load required for flexure to an angle of 30 degrees. The Mann-Whitney U test was used for statistical analysis. Findings with P <.05 were considered significant. Results: The mean load required to bend instruments at a 30 degrees angle was 376.26 g for implanted instruments and 383.78 g for nonimplanted instruments. The difference was not statistically significant. Conclusions: Our findings show that nitrogen ion implantation has no appreciable effect on the flexibility of NiTi instruments. (J Endod 2012;38:673-675)
Resumo:
Este estudo verificou o efeito agudo dos exercícios de flexibilidade estática (EFlex) no desempenho de força máxima (FM) e de resistência de força (RF) em membros inferiores e superiores. Treze voluntários participaram do estudo e foram submetidos a testes de FM e RF (70% 1RM) nos exercícios supino e agachamento precedidos ou não de EFlex. O teste T pareado foi utilizado para comparação das médias nas duas condições. Os EFlex diminuíram a FM no agachamento (141,2±34,2 vs 132±34,9kg; p=0,007) e no supino (77,5±21,7 vs 71,7±17,7kg p=0,04). A RF no agachamento não sofreu efeito dos EFlex (16,2±5,7 vs 16,3±6,8 repetições p=0,48), porém, no supino a RF apresentou diminuição significante (11,7±4,8 vs 9,9±5,1 repetições; p=0,008). Portanto, os EFlex reduziram a FM nos membros inferiores e superiores e a RF somente nos membros superiores. Essa diferença na RF estaria relacionada ao volume de exercícios de flexibilidade pelo tamanho do grupo muscular.
Resumo:
We consider a general class of mathematical models for stochastic gene expression where the transcription rate is allowed to depend on a promoter state variable that can take an arbitrary (finite) number of values. We provide the solution of the master equations in the stationary limit, based on a factorization of the stochastic transition matrix that separates timescales and relative interaction strengths, and we express its entries in terms of parameters that have a natural physical and/or biological interpretation. The solution illustrates the capacity of multiple states promoters to generate multimodal distributions of gene products, without the need for feedback. Furthermore, using the example of a three states promoter operating at low, high, and intermediate expression levels, we show that using multiple states operons will typically lead to a significant reduction of noise in the system. The underlying mechanism is that a three-states promoter can change its level of expression from low to high by passing through an intermediate state with a much smaller increase of fluctuations than by means of a direct transition.