5 resultados para FRONT-TRACKING METHOD

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes a methodology to simulate free surface incompressible multiphase flows. This novel methodology allows the simulation of multiphase flows with an arbitrary number of phases, each of them having different densities and viscosities. Surface and interfacial tension effects are also included. The numerical technique is based on the GENSMAC front-tracking method. The velocity field is computed using a finite-difference discretization of a modification of the NavierStokes equations. These equations together with the continuity equation are solved for the two-dimensional multiphase flows, with different densities and viscosities in the different phases. The governing equations are solved on a regular Eulerian grid, and a Lagrangian mesh is employed to track free surfaces and interfaces. The method is validated by comparing numerical with analytic results for a number of simple problems; it was also employed to simulate complex problems for which no analytic solutions are available. The method presented in this paper has been shown to be robust and computationally efficient. Copyright (c) 2012 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents an optimum user-steered boundary tracking approach for image segmentation, which simulates the behavior of water flowing through a riverbed. The riverbed approach was devised using the image foresting transform with a never-exploited connectivity function. We analyze its properties in the derived image graphs and discuss its theoretical relation with other popular methods such as live wire and graph cuts. Several experiments show that riverbed can significantly reduce the number of user interactions (anchor points), as compared to live wire for objects with complex shapes. This paper also includes a discussion about how to combine different methods in order to take advantage of their complementary strengths.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A derivative spectrophotometric method was validated for quzintification of acyclovir in poly (n-butylcyanoacrylate) (PBCA) nanoparticles. Specificity, linearity. precision, accuracy, recovery. detection (LOD) and quantification (LOQ) Inuits were established for method validation. First-derivative it 295.2 nm eliminated interferences from nanoparticle ingredients and presented linearity for acyclovir concentrations ranging front 1.25 to 40.0 mu g/mL. (r = 0.9999). Precision and accuracy data demonstrated good reproducibility. Recovery ranged from 99.3 to 101.2. LOD) was 0.08 mu g/mL and LOQ. 0.25 mu g/mL. Thus. the proposed method proved to be easy. low cost. and accurate, and therefore, an useful alternative to quantify acyclovir in nanoparticles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The high and increasing prevalence of Dilated Cardiomyopathy (DCM) represents a serious public health issue. Novel technologies have been used aiming to improve diagnosis and the therapeutic approach. In this context, speckle tracking echocardiography (STE) uses natural myocardial markers to analyze the systolic deformation of the left ventricle (LV). Objective: Measure the longitudinal transmural global strain (GS) of the LV through STE in patients with severe DCM, comparing the results with normal individuals and with echocardiographic parameters established for the analysis of LV systolic function, in order to validate the method in this population. Methods: Seventy-one patients with severe DCM (53 +/- 12 years, 72% men) and 20 controls (30 +/- 8 years, 45% men) were studied. The following variables were studied: LV volumes and ejection fraction calculated by two and three-dimensional echocardiography, Doppler parameters, Tissue Doppler Imaging systolic and diastolic LV velocities and GS obtained by STE. Results: Compared with controls, LV volumes were higher in the DCM group; however, LVEF and peak E-wave velocity were lower in the latter. The myocardial performance index was higher in the patient group. Tissue Doppler myocardial velocities (S', e', a') were significantly lower and E/e' ratio was higher in the DCM group. GS was decreased in the DCM group (-5.5% +/- 2.3%) when compared with controls (-14.0% +/- 1.8%). Conclusion: In this study, GS was significantly lower in patients with severe DCM, bringing new perspectives for therapeutic approaches in this specific population. (Arq Bras Cardiol 2012;99(3):834-842)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pollen traps used for harvesting pollen from Apis mellifera do not work for stingless bees, as most species have small entrances and rapidly deposit large quantities of propolis at any barrier in front of the nest. Some stingless beekeepers harvest pollen by removing it directly from pollen pots, but this pollen is normally fermented and unpalatable. The aim of this study was to test a new method for harvesting pollen from stingless bee colonies before it begins to ferment. Colonies of Scaptotrigona depilis were removed and replaced by empty hives, which were occupied by the returning foragers and used for storing pollen and nectar. After one week, the pollen and honey were harvested directly from the storing pots and weighed. On average, the colonies produced 8.7 g of honey and 54.2 g of unfermented pollen (n = 10). This method is a viable option for harvesting unfermented pollen from stingless bees, especially with species that harvest large amounts of pollen. The unfermented pollen of S. depilis was well received in taste tests, receiving higher scores than fermented pollen, and similar scores to A. mellifera pollen, so could have great commercial possibilities. It is also a good method for studying the foraging of stingless bees because the amount of harvested food can be easily and precisely quantified.