20 resultados para Evoked Potentials, Visual

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To characterize the PI component of long latency auditory evoked potentials (LLAEPs) in cochlear implant users with auditory neuropathy spectrum disorder (ANSD) and determine firstly whether they correlate with speech perception performance and secondly whether they correlate with other variables related to cochlear implant use. Methods: This study was conducted at the Center for Audiological Research at the University of Sao Paulo. The sample included 14 pediatric (4-11 years of age) cochlear implant users with ANSD, of both sexes, with profound prelingual hearing loss. Patients with hypoplasia or agenesis of the auditory nerve were excluded from the study. LLAEPs produced in response to speech stimuli were recorded using a Smart EP USB Jr. system. The subjects' speech perception was evaluated using tests 5 and 6 of the Glendonald Auditory Screening Procedure (GASP). Results: The P-1 component was detected in 12/14 (85.7%) children with ANSD. Latency of the P-1 component correlated with duration of sensorial hearing deprivation (*p = 0.007, r = 0.7278), but not with duration of cochlear implant use. An analysis of groups assigned according to GASP performance (k-means clustering) revealed that aspects of prior central auditory system development reflected in the P-1 component are related to behavioral auditory skills. Conclusions: In children with ANSD using cochlear implants, the P-1 component can serve as a marker of central auditory cortical development and a predictor of the implanted child's speech perception performance. (c) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies about cortical auditory evoked potentials using the speech stimuli in normal hearing individuals are important for understanding how the complexity of the stimulus influences the characteristics of the cortical potential generated. OBJECTIVE: To characterize the cortical auditory evoked potential and the P3 auditory cognitive potential with the vocalic and consonantal contrast stimuli in normally hearing individuals. METHOD: 31 individuals with no risk for hearing, neurologic and language alterations, in the age range between 7 and 30 years, participated in this study. The cortical auditory evoked potentials and the P3 auditory cognitive one were recorded in the Fz and Cz active channels using consonantal (/ba/-/da/) and vocalic (/i/-/a/) speech contrasts. Design: A crosssectional prospective cohort study. RESULTS: We found a statistically significant difference between the speech contrast used and the latencies of the N2 (p = 0.00) and P3 (p = 0.00) components, as well as between the active channel considered (Fz/Cz) and the P3 latency and amplitude values. These correlations did not occur for the exogenous components N1 and P2. CONCLUSION: The speech stimulus contrast, vocalic or consonantal, must be taken into account in the analysis of the cortical auditory evoked potential, N2 component, and auditory cognitive P3 potential.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transient visual evoked cortical potentials (VECP) were recorded from the scalp of healthy normal trichromats (n = 12). VECPs were elicited by onset/offset presentation of patterned stimuli of two kinds: isochromatic luminance-modulated, and equiluminant red-green modulated, sine wave gratings. The amplitude and latency of the major onset components of the onset/offset VECP were measured and plotted as a function of the logarithm of pooled cone contrast. The early onset components, achromatic C1 and chromatic N1, increase linearly with log contrast, but N1 has a higher contrast gain than C1. The late onset components, achromatic C2 and chromatic N2, have similar contrast gain, and similar response as a function of contrast level: both increase in the low-to-medium range of contrasts and saturate at high contrast levels. In the range of pooled cone contrast tested, C1 and N1 show similar latencies, whilst C2 shows shorter latencies than N2. We suggest that C1 and N1 are generated by the same visual mechanism with high red-green contrast gain and low luminance contrast gain, whilst C2 and N2 are generated by different visual mechanisms.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1A degrees and 15` check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays` electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (+/- 3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 +/- A 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background Conventional protocols of high-frequency repetitive transcranial magnetic stimulation (rTMS) delivered to M1 can produce analgesia. Theta burst stimulation (TBS), a novel rTMS paradigm, is thought to produce greater changes in M1 excitability than conventional protocols. After a preliminary experiment showing no analgesic effect of continuous or intermittent TBS trains (cTBS or iTBS) delivered to M1 as single procedures, we used TBS to prime a subsequent session of conventional 10?Hz-rTMS. Methods In 14 patients with chronic refractory neuropathic pain, navigated rTMS was targeted over M1 hand region, contralateral to painful side. Analgesic effects were daily assessed on a visual analogue scale for the week after each 10?Hz-rTMS session, preceded or not by TBS priming. In an additional experiment, the effects on cortical excitability parameters provided by single- and paired-pulse TMS paradigms were studied. Results Pain level was reduced after any type of rTMS procedure compared to baseline, but iTBS priming produced greater analgesia than the other protocols. Regarding motor cortex excitability changes, the analgesic effects were associated with an increase in intracortical inhibition, whatever the type of stimulation, primed or non-primed. Conclusions The present results show that the analgesic effects of conventional 10?Hz-rTMS delivered to M1 can be enhanced by TBS priming, at least using iTBS. Interestingly, the application of cTBS and iTBS did not produce opposite modulations, unlike previously reported in other systems. It remains to be determined whether the interest of TBS priming is to generate a simple additive effect or a more specific process of cortical plasticity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Increased, decreased or normal excitability to transcranial magnetic stimulation (TMS) has been reported in the motor (M1) and visual cortices of patients with migraine. Light deprivation (LD) has been reported to modulate M1 excitability in control subjects (CS). Still, effects of LD on M1 excitability compared to exposure to environmental light exposure (EL) had not been previously described in patients with migraine (MP). To further our knowledge about differences between CS and MP, regarding M1 excitability and effects of LD on M1 excitability, we opted for a novel approach by extending measurement conditions. We measured motor thresholds (MTs) to TMS, short-interval intracortical inhibition, and ratios between motor-evoked potential amplitudes and supramaximal M responses in MP and CS on two different days, before and after LD or EL. Motor thresholds significantly increased in MP in LD and EL sessions, and remained stable in CS. There were no significant between-group differences in other measures of TMS. Short-term variation of MTs was greater in MP compared to CS. Fluctuation in excitability over hours or days in MP is an issue that, until now, has been relatively neglected. The results presented here will help to reconcile conflicting observations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study verifies the effects of contralateral noise on otoacoustic emissions and auditory evoked potentials. Short, middle and late auditory evoked potentials as well as otoacoustic emissions with and without white noise were assessed. Twenty-five subjects, normal-hearing, both genders, aged 18 to 30 years, were tested. In general, latencies of the various auditory potentials were increased at noise conditions, whereas amplitudes were diminished at noise conditions for short, middle and late latency responses combined in the same subject. The amplitude of otoacoustic emission decreased significantly in the condition with contralateral noise in comparison to the condition without noise. Our results indicate that most subjects presented different responses between conditions (with and without noise) in all tests, thereby suggesting that the efferent system was acting at both caudal and rostral portions of the auditory system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: The effects of lead on children’s health have been widely studied. Aim: To analyze the correlation between the long latency auditory evoked potential N2 and cognitive P3 with the level of lead poisoning in Brazilian children. Methods: This retrospective study evaluated 20 children ranging in age from 7 to 14 years at the time of audiological and electrophysiological evaluations. We performed periodic surveys of the lead concentration in the blood and basic audiological evaluations. Furthermore, we studied the auditory evoked potential long latency N2 and cognitive P3 by analyzing the absolute latency of the N2 and P3 potentials and the P3 amplitude recorded at Cz. At the time of audiological and electrophysiological evaluations, the average concentration of lead in the blood was less than 10 ug/dL. Results: In conventional audiologic evaluations, all children had hearing thresholds below 20 dBHL for the frequencies tested and normal tympanometry findings; the auditory evoked potential long latency N2 and cognitive P3 were present in 95% of children. No significant correlations were found between the blood lead concentration and latency (p = 0.821) or amplitude (p = 0.411) of the P3 potential. However, the latency of the N2 potential increased with the concentration of lead in the blood, with a significant correlation (p = 0.030). Conclusion: Among Brazilian children with low lead exposure, a significant correlation was found between blood lead levels and the average latency of the auditory evoked potential long latency N2; however, a significant correlation was not observed for the amplitude and latency of the cognitive potential P3

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The neural control of the cardiovascular system is a complex process that involves many structures at different levels of nervous system. Several cortical areas are involved in the control of systemic blood pressure, such as the sensorimotor cortex, the medial prefrontal cortex and the insular cortex. Non-invasive brain stimulation techniques - repetitive transcranial magnetic stimulation (rTMS) and transcranial direct current stimulation (tDCS) - induce sustained and prolonged functional changes of the human cerebral cortex. rTMS and tDCS has led to positive results in the treatment of some neurological and psychiatric disorders. Because experiments in animals show that cortical modulation can be an effective method to regulate the cardiovascular system, non-invasive brain stimulation might be a novel tool in the therapeutics of human arterial hypertension. We here review the experimental evidence that non-invasive brain stimulation can influence the autonomic nervous system and discuss the hypothesis that focal modulation of cortical excitability by rTMS or tDCS can influence sympathetic outflow and, eventually, blood pressure, thus providing a novel therapeutic tool for human arterial hypertension. (C) 2009 Published by Elsevier Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: To establish normative amplitude values for relative difference measurements of the middle latency response (MLR) in normal-hearing pediatrics and to determine if these measurements provided a significant reduction of within-group variability when compared to raw, absolute amplitude measures. A relative amplitude difference is defined in the present paper as the difference in Na-Pa amplitude between two electrodes (e.g. vertical bar Na-Pa at C3 minus Na-Pa at C4 vertical bar, or electrode effects) or between two ears (e.g. vertical bar Na-Pa on left ear stimulation minus Na-Pa on right ear stimulation vertical bar, or ear effects). In contrast, an absolute amplitude is defined as a single Na-Pa measurement made at one electrode for stimulation of one ear (e.g. Na-Pa measured at C3 on left ear stimulation). Design: Cross-sectional study. Study sample: 155 pediatrics with normal peripheral and central hearing, and no history of psychological, neurological, or learning disability issues. Results: Within-group variability was significantly smaller for relative differences when compared to absolute amplitude measures. Electrode effects showed significantly less variability than ear effects. Normative values for ear and electrode effects were reported. Conclusions: Relative differences may provide better utility in the clinical diagnosis of central auditory pathology in pediatrics when compared to absolute amplitude measures because these difference measures show significantly lower variability when examined across subjects.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Local anesthetic efficacy of tramadol has been reported following intradermal application. Our aim was to investigate the effect of perineural tramadol as the sole analgesic in two pain models. Male Wistar rats (280-380 g; N = 5/group) were used in these experiments. A neurostimulation-guided sciatic nerve block was performed and 2% lidocaine or tramadol (1.25 and 5 mg) was perineurally injected in two different animal pain models. In the flinching behavior test, the number of flinches was evaluated and in the plantar incision model, mechanical and heat thresholds were measured. Motor effects of lidocaine and tramadol were quantified and a motor block score elaborated. Tramadol, 1.25 mg, completely blocked the first and reduced the second phase of the flinching behavior test. In the plantar incision model, tramadol (1.25 mg) increased both paw withdrawal latency in response to radiant heat (8.3 +/- 1.1, 12.7 +/- 1.8, 8.4 +/- 0.8, and 11.1 +/- 3.3 s) and mechanical threshold in response to von Frey filaments (459 +/- 82.8, 447.5 +/- 91.7, 320.1 +/- 120, 126.43 +/- 92.8 mN) at 5, 15, 30, and 60 min, respectively. Sham block or contralateral sciatic nerve block did not differ from perineural saline injection throughout the study in either model. The effect of tramadol was not antagonized by intraperitoneal naloxone. High dose tramadol (5 mg) blocked motor function as well as 2% lidocaine. In conclusion, tramadol blocks nociception and motor function in vivo similar to local anesthetics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the present study, we evaluated peripheral and central auditory pathways in professional musicians (with and without hearing loss) compared to non-musicians. The goal was to verify if music exposure could affect auditory pathways as a whole. This is a prospective study that compared the results obtained between three groups (musicians with and without hearing loss and non-musicians). Thirty-two male individuals participated and they were assessed by: Immittance measurements, pure-tone air conduction thresholds at all frequencies from 0.25 to 20 kHz, Transient Evoked Otoacoustic Emissions, Auditory Brainstem Response (ABR), and Cognitive Potential. The musicians showed worse hearing thresholds in both conventional and high frequency audiometry when compared to the non-musicians; the mean amplitude of Transient Evoked Otoacoustic Emissions was smaller in the musicians group, but the mean latencies of Auditory Brainstem Response and Cognitive Potential were diminished in the musicians when compared to the non-musicians. Our findings suggest that the population of musicians is at risk for developing music-induced hearing loss. However, the electrophysiological evaluation showed that latency waves of ABR and P300 were diminished in musicians, which may suggest that the auditory training to which these musicians are exposed acts as a facilitator of the acoustic signal transmission to the cortex.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The harm upon the central auditory pathways of workers exposed to occupational noise has been scarcely studied. Objective: To assess the central auditory pathways by testing the long latency auditory evoked potentials (P300) of individuals exposed to occupational noise and controls. Method: This prospective study enrolled 25 individuals with normal hearing thresholds. The subjects were divided into two groups: individuals exposed to occupational noise (13 subjects; case group) and individuals not exposed to occupational noise (12 subjects; control group). The P300 test was used with verbal and non-verbal stimuli. Results: No statistically significant differences were found between ears for any of the stimuli or between groups. The groups had no statistically significant difference for verbal or non-verbal stimuli. Case group subjects had longer latencies than controls. In qualitative analysis, a greater number of altered P300 test results for verbal and non-verbal stimuli was seen in the case group, despite the absence of statistically significant differences between case and control subjects. Conclusion: Individuals exposed to high sound pressure levels had longer P300 latencies in verbal and non-verbal stimuli when compared to controls.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CONTEXT AND OBJECTIVE: Children and adolescents who live in situations of social vulnerability present a series of health problems. Nonetheless, affirmations that sensory and cognitive abnormalities are present are a matter of controversy. The aim of this study was to investigate aspects to auditory processing, through applying the brainstem auditory evoked potential (BAEP) and behavioral auditory processing tests to children living on the streets, and comparison with a control group. DESIGN AND SETTING: Cross-sectional study in the Laboratory of Auditory Processing, School of Medicine, Universidade de São Paulo. METHODS: The auditory processing tests were applied to a group of 27 individuals, subdivided into 11 children (7 to 10 years old) and 16 adolescents (11 to 16 years old), of both sexes, in situations of social vulnerability, compared with an age-matched control group of 10 children and 11 adolescents without complaints. The BAEP test was also applied to investigate the integrity of the auditory pathway. RESULTS: For both children and adolescents, there were significant differences between the study and control groups in most of the tests applied, with significantly worse performance in the study group, except in the pediatric speech intelligibility test. Only one child had an abnormal result in the BAEP test. CONCLUSIONS: The results showed that the study group (children and adolescents) presented poor performance in the behavioral auditory processing tests, despite their unaltered auditory brainstem pathways, as shown by their normal results in the BAEP test.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUÇÃO: Trata-se de uma semiologia laboratorial objetiva para avaliação do sistema auditivo de crianças com distúrbio de aprendizagem. OBJETIVO: Examinar os componentes do potencial evocado auditivo de média latência em uma amostra de crianças com distúrbio de aprendizagem e determinar suas propriedades. MÉTODO: O estudo realizado é do tipo prospectivo contemporâneo de corte transversal, quantitativo, descritivo e exploratório. 50 crianças de ambos os sexos com 8 a 14 anos de idade dividido em dois grupos iguais, com e sem distúrbio de aprendizagem. Causas orgânicas, ambientais ou genéticas foram excluídas do estudo. RESULTADOS E CONCLUSÃO: As ondas Na, Pa, Nb foram identificadas em todos os integrantes do estudo. Os valores de latência dos componentes foram Na= 19,2 ms, Pa= 32,5 ms, Nb= 46,4 ms (grupo controle) e Na= 19,7 ms, Pa= 35,1 ms, Nb= 49,6 ms (grupo pesquisa). O valor médio de amplitude Na-Pa foi 1,4 mV para ambos os grupos. As análises mostraram diferenças funcionais entre os grupos, foi observado o hemisfério esquerdo Nb latência mais longa de Nb no hemisfério esquerdo do grupo de estudo em relação ao controle. Tal estudo promoveu informações adicionais sobre PEAML e pode ser referência para outros estudos clínicos e experimentais nesta população.