7 resultados para EPC CAPTURING R STENT (TM)
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Objective: We investigated the relation between duration of dual antiplatelet therapy (DAPT) and clinical outcomes up to 12 months after Genous (TM) endothelial progenitor cell capturing R stent (TM) placement in patients from the e-HEALING registry. Background: Cessation of (DAPT) has been shown to be associated with the occurrence of stent thrombosis (ST). After Genous placement, 1 month of DAPT is recommended. Methods: Patients were analyzed according to continuation or discontinuation of DAPT at a 30-day and 6-month landmark, excluding patients with events before the landmark. Each landmark was a new baseline, and outcomes were followed up to 12 months after stenting. The main outcome for our current analysis was target vessel failure (TVF), defined as target vessel-related cardiac death or myocardial infarction and target vessel revascularization. Secondary outcomes included ST. (Un)adjusted hazard ratios (HR) for TVF were calculated with Cox regression. Results: No difference was observed in the incidence of TVF [HR: 1.03; 95% confidence intervals (CI): 0.651.65, P = 0.89] in patients continuing DAPT (n = 4,249) at 30 days versus patients stopped (n = 309), and HR: 0.82 (95% CI: 0.551.23, P = 0.34) in patients continuing DAPT (n = 2,654) at 6 months versus patients stopped [n = 1,408] DAPT). Furthermore, no differences were observed in ST. Even after addition of identified independent predictors for TVF, adjusted TVF hazards were comparable. Conclusions: In a post-hoc analysis of e-HEALING, duration of DAPT was not associated with the occurrence of the outcomes TVF or ST. The Genous stent may be an attractive treatment especially in patients at increased risk for (temporary) cessation of DAPT or bleeding. (C) 2011 Wiley Periodicals, Inc.
Resumo:
The National Institute for Clinical Excellence (NICE) guidelines recommend the use of bare-metal stents (BMS) in non-complex lesions with a low risk of restenosis (diameter a parts per thousand yen3 mm and lesion length a parts per thousand currency sign15 mm) and the use of drug-eluting stents (DES) in more complex lesions with a high risk of restenosis (diameter < 3.0 mm or lesion length > 15 mm). However, the guidelines were created based on studies evaluating BMS and DES only. We performed an analysis of patients undergoing non-urgent percutaneous coronary intervention with the novel endothelial cell capturing stent (ECS). The ECS is coated with CD34(+) antibodies that attract circulating endothelial progenitor cells to the stent surface, thereby accelerating the endothelialization of the stented area. We analyzed all patients enrolled in the worldwide e-HEALING registry that met the NICE criteria for either low-risk or high-risk lesions and were treated with a parts per thousand yen1 ECS. The main study outcome was target vessel failure (TVF) at 12-month follow-up, defined as the composite of cardiac death or MI and target vessel revascularization (TVR). A total of 4,241 patients were assessed in the current analysis. At 12-month follow-up, TVF occurred in 7.0% of the patients with low-risk lesions and in 8.8% of the patients with high-risk lesions (p = 0.045). When evaluating the diabetic patients versus the non-diabetic patients per risk group, no significant differences were found in TVF, MI or TVR in either risk group. The ECS shows good clinical outcomes in lesions carrying either a high or a low risk of restenosis according to the NICE guidelines with comparable rates of cardiac death, myocardial infarction, and stent thrombosis. The TVF rate with ECS was slightly higher in patients with high-risk lesions, driven by higher clinically driven TLR. The risk of restenosis with ECS in patients carrying high-risk lesions needs to be carefully considered relative to other risks associated with DES. Furthermore, the presence of diabetes mellitus did not influence the incidence of TVF in either risk group.
Resumo:
Background The e-Healthy Endothelial Accelerated Lining Inhibits Neointimal Growth (e-HEALING) registry was designed to capture clinical data on the use of the endothelial progenitor cell capture stent (ECS) in routine clinical practice. In this analysis, we investigated the 12-month clinical outcomes in patients treated with an ECS for a bifurcation lesion. Methods The worldwide, prospective, nonrandomized e-HEALING registry aimed to enrol 5000 patients treated for coronary artery disease with one or more ECS between October 2005 and October 2007. Clinical follow-up was obtained at 1, 6, and 12 months. The primary endpoint was target vessel failure (TVF), defined as the composite of cardiac death, myocardial infarction, and target vessel revascularization at 12 months. Results A total of 573 patients were treated for at least one bifurcation lesion and were assessed in the current analysis. Baseline characteristics showed a median age of 65 years; 21% were diabetic patients and 36% had unstable angina. A total of 63% of the bifurcation lesions were located in the left artery descending and the mean stent length was 20.7 +/- 12.6 mm. At 12 months, TVF was 12.7% and target lesion revascularization was 7.5%. Definite or probable stent thrombosis occurred in 1.7% of the patients. Moreover, one or more stents per lesion [hazard ratio (HR): 2.79, 95% confidence interval (CI): 1.60-4.86, P < 0.001], predilatation (HR: 0.39, 95% CI: 0.17-0.87, P = 0.023), and lesions located in the right coronary artery (HR: 4.56, 95% CI: 1.07-19.5, P = 0.041) were independent predictors of TVF. Conclusion In the e-HEALING registry, coronary bifurcation stenting with the ECS results in favorable clinical outcomes and low incidences of repeat revascularization and stent thrombosis. Coron Artery Dis 23:201-207 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Resumo:
Carvalho, FLP, Carvalho, MCGA, Simao, R, Gomes, TM, Costa, PB, Neto, LB, Carvalho, RLP, and Dantas, EHM. Acute effects of a warm-up including active, passive, and dynamic stretching on vertical jump performance. J Strength Cond Res 26(9): 2447-2452, 2012-The purpose of this study was to examine the acute effects of 3 different stretching methods combined with a warm-up protocol on vertical jump performance. Sixteen young tennis players (14.5 +/- 2.8 years; 175 +/- 5.6 cm; 64.0 +/- 11.1 kg) were randomly assigned to 4 different experimental conditions on 4 successive days. Each session consisted of a general and specific warm-up, with 5 minutes of running followed by 10 jumps, accompanied by one of the subsequent conditions: (a) Control Condition (CC)-5 minutes of passive rest; (b) Passive Stretching Condition (PSC)-5 minutes of passive static stretching; (c) Active Stretching Condition (ASC)-5 minutes of active static stretching; and (d) Dynamic Stretching Condition (DC)-5 minutes of dynamic stretching. After each intervention, the subjects performed 3 squat jumps (SJs) and 3 countermovement jumps (CMJs), which were measured electronically. For the SJ, 1-way repeated measures analysis of variance (CC x PSC x ASC x DC) revealed significant decreases for ASC (28.7 +/- 4.7 cm; p = 0.01) and PSC (28.7 +/- 4.3 cm; p = 0.02) conditions when compared with CC (29.9 +/- 5.0 cm). For CMJs, there were no significant decreases (p > 0.05) when all stretching conditions were compared with the CC. Significant increases in SJ performance were observed when comparing the DC (29.6 +/- 4.9 cm; p = 0.02) with PSC (28.7 +/- 4.3 cm). Significant increases in CMJ performance were observed when comparing the conditions ASC (34.0 +/- 6.0 cm; p = 0.04) and DC (33.7 +/- 5.5 cm; p = 0.03) with PSC (32.6 +/- 5.5 cm). A dynamic stretching intervention appears to be more suitable for use as part of a warm-up in young athletes.
Resumo:
INTRODUÇÃO: Os estudos com stents farmacológicos têm avaliado predominantemente populações masculinas de descendência europeia. O estudo de braço único SPIRIT Women avalia o stent eluidor de everolimus XIENCE TM V em lesões de novo complexas em uma população feminina do mundo real, incluindo pacientes latino-americanas. Esta análise permite compreender como essa população responde ao implante de stent, comparativamente a pacientes não-latino-americanas. MÉTODOS: Das 1.572 pacientes matriculadas em 73 locais fora dos Estados Unidos, 138 (9%) foram recrutadas na Argentina, no Brasil e na Venezuela. RESULTADOS: As lesões-alvo tinham diâmetro de referência do vaso entre 2,25 mm e 4 mm e extensão da lesão ≤ 28 mm. As características basais foram semelhantes entre os grupos, com exceção de maior prevalência de hipertensão arterial, infarto do miocárdio (IM) de parede anterior e história familiar de doença arterial coronária na coorte latino-americana. As lesões tendiam a ser mais complexas em mulheres latino-americanas, com menor diâmetro de referência do vaso-alvo, maior extensão da lesão, maior excentricidade e angulação e mais lesões tipo B2/C. Os eventos foram adjudicados de acordo com as definições do Academic Research Consortium. Em um ano, o desfecho combinado de morte por todas as causas, IM e revascularização do vaso-alvo (RVA) foi de 12,1% na população não-latino-americana e de 10,1% na população latino-americana (P = 0,58). CONCLUSÕES: Em um ano, os baixos índices de eventos cardíacos adversos, incluindo trombose do stent, falha da lesão-alvo, morte cardíaca, IM e RVA nas mulheres latino-americanas foram comparáveis aos das mulheres não-latino-americanas, apesar da maior complexidade das lesões. Esses resultados demonstram a segurança e a eficácia do stent XIENCE TM V nessa pequena coorte de pacientes latino-americanas, à semelhança do que é observado com populações maiores e mais variadas.
Resumo:
The aim of this study was to investigate the effects of beta-alanine supplementation on exercise capacity and the muscle carnosine content in elderly subjects. Eighteen healthy elderly subjects (60-80 years, 10 female and 4 male) were randomly assigned to receive either beta-alanine (BA, n = 12) or placebo (PL, n = 6) for 12 weeks. The BA group received 3.2 g of beta-alanine per day (2 x 800 mg sustained-release Carnosyn (TM) tablets, given 2 times per day). The PL group received 2 x (2 x 800 mg) of a matched placebo. At baseline (PRE) and after 12 weeks (POST-12) of supplementation, assessments were made of the muscle carnosine content, anaerobic exercise capacity, muscle function, quality of life, physical activity and food intake. A significant increase in the muscle carnosine content of the gastrocnemius muscle was shown in the BA group (+85.4%) when compared with the PL group (+7.2%) (p = 0.004; ES: 1.21). The time-to-exhaustion in the constant-load submaximal test (i.e., TLIM) was significantly improved (p = 0.05; ES: 1.71) in the BA group (+36.5%) versus the PL group (+8.6%). Similarly, time-to-exhaustion in the incremental test was also significantly increased (p = 0.04; ES 1.03) following beta-alanine supplementation (+12.2%) when compared with placebo (+0.1%). Significant positive correlations were also shown between the relative change in the muscle carnosine content and the relative change in the time-to-exhaustion in the TLIM test (r = 0.62; p = 0.01) and in the incremental test (r = 0.48; p = 0.02). In summary, the current data indicate for the first time, that beta-alanine supplementation is effective in increasing the muscle carnosine content in healthy elderly subjects, with subsequent improvement in their exercise capacity.
Resumo:
Background: Duodenal stenting has become a broadly accepted first line of treatment for patients with advanced malignant gastroduodenal obstruction as these patients are difficult to treat and are poor surgical candidates. Aims: To document duodenal stent performance for palliative management of malignant gastroduodenal obstruction. Methods: Multicentre, single arm, prospective registry documenting peroral endoscopic duodenal stenting procedures in 202 patients. Results: Technical success achieved in 98% (CI. 95%, 99%) of stent placements. Increase of Gastric Outlet Obstruction Score by at least 1 point compared to baseline was achieved in 91% (CI, 86%, 95%) of patients persisting for a median of 184 days (CI, 109, 266). By day 5 (CI, 4,6) after stent placement, 50% of patients experienced a score increase of at least 1 point. Improvement from 14% of patients at baseline tolerating soft solids or low residue/normal diet to 84% at 15 days, 86% at 30 days, 81% at 90 days, 79% at 180 days, and 70% at 270 days. Complications included stent ingrowth and/or overgrowth (12.4%), transient periprocedural symptoms (3%), bleeding (3%), stent migration (1.5%), and perforation (0.5%). Conclusions: Safety and effectiveness of duodenal stenting for palliation of malignant gastroduodenal obstruction was confirmed in the largest international prospective series to date. (C) 2011 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.