31 resultados para Distance Corridor Walk
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Background: Walking speed seems to be related to aerobic capacity, lower limb strength, and functional mobility, however it is not clear whether there is a direct relationship between improvement in muscle strength and gait performance in early postmenopausal women. Objective: To evaluate the effect of muscle strengthening exercises on the performance of the 6-minute walk test in women within 5 years of menopause. Methods: The women were randomized into control group (n=31), which performed no exercise, and exercise group (n=27), which performed muscle strengthening exercises. The exercises were performed twice a week for 3 months. The exercise protocol consisted of warm-up, stretching, and strengthening of the quadriceps, hamstring, calf, tibialis anterior, gluteus maximus, and abdominal muscles, followed by relaxation. Muscular strength training started with 60% of 1MR (2 series of 10-15 repetitions), reaching 85% until the end of the 3-month period (4 series of 6 repetitions each). Results: The between-group comparisons pre- and post-intervention did not show any difference in distance walked, heart rate or blood pressure (p>0.05), but showed differences in muscle strength post-intervention, with the exercise group showing greater strength (p<0.05). In the within-group comparison, there were differences in final heart rate and quadriceps and hamstring strength pre- and post-intervention in the exercise group (p<0.05). Conclusion: The results suggest that muscle strengthening of the lower limbs did not improve performance in the 6-minute walk test in this population of postmenopausal women. Trial registration ACTRN12609001053213.
Resumo:
Distances walked in walking tests are important functional markers, although they are not accepted as defining characteristics of Ineffective Peripheral Tissue Perfusion. The aims of this study were to verify the distances participants with and without this nursing diagnosis walked in the six-minute walk test and if these measures may be considered defining characteristics of this phenomenon. Participants with (group A; n=65) and without (group B; n=17) this nursing diagnosis were evaluated regarding physical examination, vascular function and functional capacity. Participants of group A seemed to have worse vascular function and functional capacity compared with those of group B. Pain-free travelled distance was predictive of the nursing diagnosis. These results are important for the refinement of this diagnosis. In conclusion, this study provides evidences that the distances walked in the six-minute walk test may be considered defining characteristics of Ineffective Peripheral Tissue Perfusion.
Resumo:
Background: The six-minute-walk-test (6MWT) has been increasingly used in cystic fibrosis (CF) patients. However, few studies in children have correlated 6MWT with current parameters used to evaluate CF severity. Moreover, no study transformed the values of distance walked from meters into Z scores to avoid bias like age and gender, which are sources of 6MWT variability. Methods: A cross-sectional descriptive study was performed to analyze the correlations (Spearman) among forced expiratory volume in one second (FEV1), body mass index (BMI), chest radiography (CXR), chest tomography (CT), and 6MWT Z score (Z-6MWT). Clinically stable CF patients, aged 6-21 years, were included. Results: 34 patients, 14F/20M, mean age 12.1 +/- 4.0 years were studied. The mean Z-6MWT was -1.1 +/- 1.106. The following correlations versus Z-6MWT were found: FEV1 (r=0.59, r(2)=0.32, p=0.0002), BMI Z score (r=0.42, r(2)=0.17, p=0.013), CXR (r=0.34, r(2)=0.15, p=0.0472) and CT (r=-0.45, r(2)=0.23, p=0.0073). Conclusions: In conclusion there was a significant, but poor, correlation between the six minute walk test Z score and the cystic fibrosis severity markers currently in use. (C) 2011 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.
Resumo:
Abstract Background The Stroke remains one of the major chronic diseases worldwide, and is considered a major cause of disability, which results not only in persistent neurological deficits, but also in the high physical deconditioning, nevertheless there are not many forms of assessing functional capacity in this population. We aimed to investigate the feasibility of the Six Minute Walk Teste and the Six-Minute Step Test (6MST) in post-stroke patients and compare the behavior of physiological variables during the 6MST and the Six-Minute Walk Test (6MWT), by correlating the functional performance obtained in both tests. Method The 6MWT was carried out according to the American Thoracic Society (ATS) and the 6MST was performed in six minutes in order to compare it to the 6MWT in a 20 cm step. Was included post-stroke individuals able to walk without aid. All of them did the 6MWT and the 6MST. Results 12 patients participated in the study. There was no statistical difference in the parameters analyzed when tests were compared. There was poor correlation between the functional performance in both tests. Conclusion The 6MWT and the 6MST is feasible for post-stroke patients and physiological responses are equal during the performance of both tests. However, there was no correlation with respect to functional performance, which was assessed by the distance walked in the 6MWT and by the number of steps climbed in the 6MST.
Resumo:
The aim of this study was to determine whether image artifacts caused by orthodontic metal accessories interfere with the accuracy of 3D CBCT model superimposition. A human dry skull was subjected three times to a CBCT scan: at first without orthodontic brackets (T1), then with stainless steel brackets bonded without (T2) and with orthodontic arch wires (T3) inserted into the brackets' slots. The registration of image surfaces and the superimposition of 3D models were performed. Within-subject surface distances between T1-T2, T1-T3 and T2-T3 were computed and calculated for comparison among the three data sets. The minimum and maximum Hausdorff Distance units (HDu) computed between the corresponding data points of the T1 and T2 CBCT 3D surface images were 0.000000 and 0.049280 HDu, respectively, and the mean distance was 0.002497 HDu. The minimum and maximum Hausdorff Distances between T1 and T3 were 0.000000 and 0.047440 HDu, respectively, with a mean distance of 0.002585 HDu. In the comparison between T2 and T3, the minimum, maximum and mean Hausdorff Distances were 0.000000, 0.025616 and 0.000347 HDu, respectively. In the current study, the image artifacts caused by metal orthodontic accessories did not compromise the accuracy of the 3D model superimposition. Color-coded maps of overlaid structures complemented the computed Hausdorff Distances and demonstrated a precise fusion between the data sets.
Resumo:
Bertuzzi, R, Bueno, S, Pasqua, LA, Acquesta, FM, Batista, MB, Roschel, H, Kiss, MAPDM, Serrao, JC, Tricoli, V, and Ugrinowitsch, C. Bioenergetics and neuromuscular determinants of the time to exhaustion at velocity corresponding to (V) over dotO(2)max in recreational long-distance runners. J Strength Cond Res 26(8): 2096-2102, 2012-The purpose of this study was to investigate the main bioenergetics and neuromuscular determinants of the time to exhaustion (T-lim) at the velocity corresponding to maximal oxygen uptake in recreational long-distance runners. Twenty runners performed the following tests on 5 different days: (a) maximal incremental treadmill test, (b) 2 submaximal tests to determine running economy and vertical stiffness, (c) exhaustive test to measured the T-lim, (d) maximum dynamic strength test, and (e) muscle power production test. Aerobic and anaerobic energy contributions during the T-lim test were also estimated. The stepwise multiple regression method selected 3 independent variables to explain T-lim variance. Total energy production explained 84.1% of the shared variance (p = 0.001), whereas peak oxygen uptake ((V) over dotO(2)peak) measured during T-lim and lower limb muscle power ability accounted for the additional 10% of the shared variance (p = 0.014). These data suggest that the total energy production, (V) over dotO(2)peak, and lower limb muscle power ability are the main physiological and neuromuscular determinants of T-lim in recreational long-distance runners.
Resumo:
We evaluated the effects of air-drying distance and bond surface area on the shear bond strength of a 2-step etch-and-rinse adhesive. A total of 120 bovine anterior teeth were equally divided into 6 main groups based on bonding surface area. The main groups were divided into sub-groups (n = 5) according to air-drying distance. The shear strength was determined using a universal testing machine at a crosshead speed of 0.5 mm/min. The averaged results were subjected to two-way ANOVA and Tukey's test (alpha = 0.05). Two-way ANOVA testing identified no significant cross-product interactions (p > 0.05), but the main factors of area (p < 0.0001) and air-drying distance (p < 0.00001) significantly affected the mean bond strength. Shorter air-drying distances improved bond strength, and increased surface area decreased the bond strength.
Resumo:
Background: The sieve analysis for the Step trial found evidence that breakthrough HIV-1 sequences for MRKAd5/HIV-1 Gag/Pol/Nef vaccine recipients were more divergent from the vaccine insert than placebo sequences in regions with predicted epitopes. We linked the viral sequence data with immune response and acute viral load data to explore mechanisms for and consequences of the observed sieve effect. Methods: Ninety-one male participants (37 placebo and 54 vaccine recipients) were included; viral sequences were obtained at the time of HIV-1 diagnosis. T-cell responses were measured 4 weeks post-second vaccination and at the first or second week post-diagnosis. Acute viral load was obtained at RNA-positive and antibody-negative visits. Findings: Vaccine recipients had a greater magnitude of post-infection CD8+ T cell response than placebo recipients (median 1.68% vs 1.18%; p = 0.04) and greater breadth of post-infection response (median 4.5 vs 2; p = 0.06). Viral sequences for vaccine recipients were marginally more divergent from the insert than placebo sequences in regions of Nef targeted by pre-infection immune responses (p = 0.04; Pol p = 0.13; Gag p = 0.89). Magnitude and breadth of pre-infection responses did not correlate with distance of the viral sequence to the insert (p. 0.50). Acute log viral load trended lower in vaccine versus placebo recipients (estimated mean 4.7 vs 5.1) but the difference was not significant (p = 0.27). Neither was acute viral load associated with distance of the viral sequence to the insert (p>0.30). Interpretation: Despite evidence of anamnestic responses, the sieve effect was not well explained by available measures of T-cell immunogenicity. Sequence divergence from the vaccine was not significantly associated with acute viral load. While point estimates suggested weak vaccine suppression of viral load, the result was not significant and more viral load data would be needed to detect suppression.
Resumo:
Cellular membranes have relevant roles in processes related to proteases like human kallikreins and cathepsins. As enzyme and substrate may interact with cell membranes and associated co-factors, it is important to take into account the behavior of peptide substrates in the lipid environment. In this paper we report an study based on energy transfer in two bradykinin derived peptides labeled with the donor-acceptor pair Abz/Eddnp (ortho-aminobenzoic acid/N-[2,4-dinitrophenyl]-ethylenediamine). Time-resolved fluorescence experiments were performed in phosphate buffer and in the presence of large unilamelar vesicles of phospholipids, and of micelles of sodium dodecyl sulphate (SDS). The decay kinetics were analyzed using the program CONTIN to obtain end-to-end distance distribution functions f(r). Despite of the large difference in the number of residues the end-to-end distance of the longer peptide (9 amino acid residues) is only 20 % larger than the values obtained for the shorter peptide (5 amino acid residues). The proline residue, in position 4 of the bradykinin sequence promotes a turn in the longer peptide chain, shortening its end-to-end distance. The surfactant SDS has a strong disorganizing effect, substantially broadening the distance distributions, while temperature increase has mild effects in the flexibility of the chains, causing small increase in the distribution width. The interaction with phospholipid vesicles stabilizes more compact conformations, decreasing end-to-end distances in the peptides. Anisotropy experiments showed that rotational diffusion was not severely affected by the interaction with the vesicles, suggesting a location for the peptides in the surface region of the bilayer, a result consistent with small effect of lipid phase transition on the peptides conformations.
Resumo:
Background: Schistosomiasis-associated pulmonary arterial hypertension (Sch-PAH) may be one of the most prevalent forms of pulmonary arterial hypertension (PAH) worldwide. However, the clinical and hemodynamical response to specific PAH therapy in Sch-PAH is not known. Methods: We retrospectively analyzed the charts of all patients with Sch-PAH who initiated specific PAH treatment between June 2003 and June 2010 in a single PAH reference center in Sao Paulo, Brazil. Clinical and hemodynamical data were retrospectively collected and evaluated in two periods: baseline and posttreatment. Results: The study population consisted of 12 patients with Sch-PAH. They were treated with phosphodiseterase-5 inhibitors (seven patients), endothelin receptor antagonists (four patients), or combination therapy (one patient). Mean treatment period was 34.9 +/- 15.5 months. Patients with Sch-PAH presented significant improvements in terms of functional class, 6-min walk test distance (439 +/- 85 to 492 +/- 79 m, P = .032), cardiac index (2.66 +/- 0.59 to 3.08 +/- 0.68 L/min/m(2), P = .028), and indexed pulmonary vascular resistance (20.7 +/- 11.6 to 15.9 +/- 9 W/m(2), P = .038) with the introduction of specific PAH treatment. Conclusions: We conclude that specific PAH therapy may be of benefit to patients with Sch-PAH, considering clinical, functional, and hemodynamic parameters. CHEST 2012; 141(4):923-928
Resumo:
Deutsche Forschungsgemeinschaft [SFB 858]
Resumo:
In Brazil, Protected Areas (PAs) are considered the cornerstone for development of national strategies for biodiversity conservation. Considering this point of view we analyzed thirty protected areas belonging to Atlantic Central Corridor of Atlantic Forest in Bahia, aiming to identify and analyze its current level of implementation. Lemos de Sa and Ferreira (2000) methodology which consist of applying a standard scale, where the variation of the level of implementation conforms to a range of 0 to 5 points was used, with appropriate adaptations. After obtaining the data from the implementation level we use the aggregation method of Ward to help visualize the dissimilarity between the protected areas studied. We used an international classification proposed by IUCN (International Union for Conservation of Nature) for that the UCs to be compared with works done in another countries, the UCs considered are in the groups Ia, II, V and VI da IUCN. As results, 50% of protected areas analyzed are reasonably implemented, 40% inadequately implemented, 6.7% are presented only on paper and only 3.3% can be classified as satisfactorily implemented. These areas presents problems in their regularization; deficiency in infrastructure, human and financial resources. Given the results its clear the recurrent fact that conservation areas under study must be effectively implemented and for this to occur environmental policies should be focused on actions to consolidate the goals of conservation strategy.
Resumo:
Background: Lymphangioleiomyomatosis (LAM) is characterised by progressive airway obstruction and hypoxaemia in young women. Although sleep may trigger hypoxaemia in patients with airway obstruction, it has not been previously investigated in patients with LAM. Methods: Consecutive women with lung biopsy proven LAM and absence of hypoxaemia while awake were evaluated with pulmonary function test, echocardiography, 6-min walk test, overnight full polysomnography, and Short Form 36 health-related quality-of-life questionnaire. Results: Twenty-five patients with (mean +/- SD) age 45 +/- 10 years, SpO(2) awake 95% +/- 2, forced expiratory volume in the first second (median-interquartile) FEV1 (% predicted) 77 (47-90) and carbonic monoxide diffusion capacity, DLCO (%) 55 (34-74) were evaluated. Six-minute walk test distance and minimum SpO(2) (median-interquartile) were, respectively, 447 m (411 -503) and 90% (82-94). Median interquartile apnoea-hypopnoea index was in the normal range 2 (1-5). Fourteen patients (56%) had nocturnal hypoxaemia (10% total sleep time with SpO(2) <90%), and the median sleep time spent with SpO(2) <90% was 136 (13-201) min. Sleep time spent with SpO(2) <90% correlated with the residual volume/total lung capacity ratio (r(s) = 0.5, p: 0.02), DLCO (r(s) = -0.7, p: 0.001), FEV1 (r(s) = -0.6, p: 0.002). Multivariate linear regression model showed that RV/TLC ratio was the most important functional variable related to sleep hypoxaemia. Conclusion: Significant hypoxaemia during sleep is common in LAM patients with normal SpO(2) while awake, especially among those with some degree of hyperinflation in lung function tests. (C) 2011 Published by Elsevier Ltd.
Resumo:
The effect of the relationship between particle size (d), inter-particle distance (x(i)), and metal loading (y) of carbon supported fuel cell Pt or PtRu catalysts on their catalytic activity, based on the optimum d (2.5-3 nm) and x(i)/d (>5) values, was evaluated. It was found that for y < 30 wt%, the optimum values of both d and x(i)/d can be always obtained. For y >= 30 wt%, instead, the positive effect of a thinner catalyst layer of the fuel cell electrode than that using catalysts with y < 30 wt% is concomitant to a decrease of the effective catalyst surface area due to an increase of d and/or a decrease of x(i)/d compared to their optimum values, with in turns gives rise to a decrease in the catalytic activity. The effect of the x(i)/d ratio has been successfully verified by experimental results on ethanol oxidation on PtRu/C catalysts with same particle size and same degree of alloying but different metal loading. Tests in direct ethanol fuel cells showed that, compared to 20 wt% PtRu/C, the negative effect of the lower x(i)/d on the catalytic activity of 30 and 40 wt% PtRu/C catalysts was superior to the positive effect of the thinner catalyst layer.
Resumo:
Long-distance correlations (LDCs) of plasma potential fluctuations in the plasma edge have been investigated in the TCABR tokamak in the regime of edge biasing H-mode using an array of multi-pin Langmuir probes. This activity was carried out as part of the scientific programme of the 4th IAEA Joint Experiment (2009). The experimental data confirm the effect of amplification of LDCs in potential fluctuations during biasing recently observed in stellarators and tokamaks. For long toroidal distances between probes, the cross-spectrum is concentrated at low frequencies f < 60 kHz with peaks at f < 5 kHz, f = 13-15 kHz and f similar to 40 kHz and low wave numbers with a maximum at k = 0. The effects of MHD activity on the LDCs in potential fluctuation are investigated.