2 resultados para Dimensional Diameter
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.
Resumo:
Objective To evaluate and compare the intraobserver and interobserver reliability and agreement for the biparietal diameter (BPD), abdominal circumference (AC), femur length (FL) and estimated fetal weight (EFW) obtained by two-dimensional ultrasound (2D-US) and three-dimensional ultrasound (3D-US). Methods Singleton pregnant women between 24 and 40 weeks were invited to participate in this study. They were examined using 2D-US in a blinded manner, twice by one observer, intercalated by a scan by a second observer, to determine BPD, AC and FL. In each of the three examinations, three 3D-US datasets (head, abdomen and thigh) were acquired for measurements of the same parameters. We determined EFW using Hadlock's formula. Systematic errors between 3D-US and 2D-US were examined using the paired t-test. Reliability and agreement were assessed by intraclass correlation coefficients (ICCs), limits of agreement (LoA), SD of differences and proportion of differences below arbitrary points. Results We evaluated 102 singleton pregnancies. No significant systematic error between 2D-US and 3D-US was observed. The ICC values were higher for 3D-US in both intra- and interobserver evaluations; however, only for FL was there no overlap in the 95% CI. The LoA values were wider for 2D-US, suggesting that random errors were smaller when using 3D-US. Additionally, we observed that the SD values determined from 3D-US differences were smaller than those obtained for 2D-US. Higher proportions of differences were below the arbitrarily defined cut-off points when using 3D-US. Conclusion 3D-US improved the reliability and agreement of fetal measurements and EFW compared with 2D-US.