Purpose: To evaluate endothelial cell sample size and statistical error in corneal specular microscopy (CSM) examinations. Methods: One hundred twenty examinations were conducted with 4 types of corneal specular microscopes: 30 with each BioOptics, CSO, Konan, and Topcon corneal specular microscopes. All endothelial image data were analyzed by respective instrument software and also by the Cells Analyzer software with a method developed in our lab(US Patent). A reliability degree (RD) of 95% and a relative error (RE) of 0.05 were used as cut-off values to analyze images of the counted endothelial cells called samples. The sample size mean was the number of cells evaluated on the images obtained with each device. Only examinations with RE<0.05 were considered statistically correct and suitable for comparisons with future examinations. The Cells Analyzer software was used to calculate the RE and customized sample size for all examinations. Results: Bio-Optics: sample size, 97 +/- 22 cells; RE, 6.52 +/- 0.86; only 10% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 162 +/- 34 cells. CSO: sample size, 110 +/- 20 cells; RE, 5.98 +/- 0.98; only 16.6% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 157 +/- 45 cells. Konan: sample size, 80 +/- 27 cells; RE, 10.6 +/- 3.67; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 336 +/- 131 cells. Topcon: sample size, 87 +/- 17 cells; RE, 10.1 +/- 2.52; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 382 +/- 159 cells. Conclusions: A very high number of CSM examinations had sample errors based on Cells Analyzer software. The endothelial sample size (examinations) needs to include more cells to be reliable and reproducible. The Cells Analyzer tutorial routine will be useful for CSM examination reliability and reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The methodology currently used for interpretation of the cornea and anterior segment tomography for the diagnosis of corneal ectasia and its susceptibility. Methods: Description of the methodology and clinical interpretation of corneal and anterior segment tomography indexes; report of three cases demonstrating the importance of this new diagnostic tool (Pentacam HR (R)) in ophthalmological practice. Conclusion: The use of corneal and anterior segment tomography seems to be an effective method to increase the sensitivity and specificity for the diagnosis and early detection of corneal ectasia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

How is the corneal epithelium restored when all of it plus the limbus have been eliminated? This investigation explored the possibility that this may be achieved through the conjunctival epithelium. The corneal epithelium of the right eye of 12 rabbits (Oryctolagus cuniculus) was totally scraped followed by surgical excision of the limbus plus 1.0-1.5 mm of the adjacent conjunctiva. Antibiotics and corticosteroids were applied for 1 week after surgery. Histological and immunohistochemical techniques were used to monitor the events taking place on the eye surface 2 weeks and 1, 3 and 6 months thereafter. Initially, the corneal surface was covered by conjunctival-like epithelium. After 1 month and more prominently at 3 and 6 months an epithelium displaying the morphological features of the cornea and reacting with the AE5 antibody was covering the central region. It is likely that the corneal epithelium originated from undifferentiated cells of the conjunctiva interacting with the corneal stroma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper presents a historical study on the acceptance of Newton's corpuscular theory of light in the early eighteenth century. Isaac Newton first published his famous book Opticks in 1704. After its publication, it became quite popular and was an almost mandatory presence in cultural life of Enlightenment societies. However, Newton's optics did not become popular only via his own words and hands, but also via public lectures and short books with scientific contents devoted to general public (including women) that emerged in the period as a sort of entertainment business. Lectures and writers stressed the inductivist approach to the study of nature and presented Newton's ideas about optics as they were consensual among natural philosophers in the period. The historical case study presented in this paper illustrates relevant aspects of nature of science, which can be explored by students of physics on undergraduate level or in physics teacher training programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess corneal wavefront-guided photorefractive keratectomy (PRK) to correct hyperopia after radial keratotomy (RK). SETTING: Sadalla Amin Ghanem Eye Hospital, Joinville, Santa Catarina, Brazil. DESIGN: Case series. METHODS: Excimer laser corneal wavefront-guided PRK with intraoperative mitomycin-C (MMC) 0.02% was performed. Main outcome measures were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, spherical equivalent (SE), corneal aberrations, and haze. RESULTS: The mean time between RK and PRK in the 61 eyes (39 patients) was 18.8 years +/- 3.8 (SD). Before PRK, the mean SE was +4.17 +/- 1.97 diopters (D); the mean astigmatism, -1.39 +/- 1.04 D; and the mean CDVA, 0.161 +/- 0.137 logMAR. At 24 months, the mean values were 0.14 +/- 0.99 D (P<.001), -1.19 +/- 1.02 D (P=.627), and 0.072 +/- 0.094 logMAR (P<.001), respectively; the mean UDVA was 0.265 +/- 0.196 (P<.001). The UDVA was 20/25 or better in 37.7% of eyes and 20/40 or better in 68.9%. The CDVA improved by 1 or more lines in 62.3% of eyes. Two eyes (3.3%) lost 2 or more lines, 1 due to corneal ectasia. Thirty eyes (49.2%) were within +/- 0.50 D of intended SE and 45 (73.8%) were within +/- 1.00 D. From 6 to 24 months, the mean SE regression was +0.39 D (P<.05). A significant decrease in coma, trefoil, and spherical aberration occurred. Three eyes developed peripheral haze more than grade 1. CONCLUSION: Corneal wavefront-guided PRK with MMC for hyperopia after RK significantly improved UDVA, CDVA, and higher-order corneal aberrations with a low incidence of visually significant corneal haze.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To present 7 cases of peripheral sterile corneal infiltrates that occurred after corneal cross-linking (CXL) for progressive keratectasia. Methods: Seven patients who had their progressive keratoconus documented underwent corneal deepithelization and subsequently CXL, which was performed with the application of 0.1% riboflavin with 20% dextran, and exposure to UVA light (370 nm, 2.9-3.1 mW/cm(2)) for 30 minutes. Results: Nearly a week after the procedure, the patients presented with peripheral stromal infiltrates. The ring-like infiltrates were superficial and were present at the 9.0-mm zone. Sterile infiltration was diagnosed. Patients were treated with topical corticosteroids, and complete resolution was achieved after a few weeks of treatment. Conclusions: We hypothesize that the phototoxic effect on the corneal stroma may be the main mechanism that triggers these infiltrates. Alternatively, alterations in antigenicity that occur in native proteins after CXL could result in patients recognizing the proteins as nonself and mounting immune responses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of edge covalent functionalization on the structural, electronic, and optical properties of elongated armchair graphene nanoflakes (AGNFs) are analyzed in detail for a wide range of terminations, within the framework of Hartree-Fock-based semiempirical methods. The chemical features of the functional groups, their distribution, and the resulting system symmetry are identified as the key factors that determine the modification of strutural and optoelectronic features. While the electronic gap is always reduced in the presence of substituents, functionalization-induced distortions contribute to the observed lowering by about 35-55% This effect is paired with a red shift of the first optical peak, corresponding to about 75% of the total optical gap reduction. Further, the functionalization pattern and the specific features of the edge-substituent bond are found to influence the strength and the character of the low-energy excitations. All of these effects are discussed for flakes of different widths, representing the three families of AGNFs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background High astigmatisms are usually induced during corneal suturing subsequent to tissue transplantation or any other surgery which involves corneal suturing. One of the reasons is that the procedure is intimately dependent on the surgeon's skill for suturing identical stitches. In order to evaluate the influence of the irregularity on suturing for the residual astigmatism, a prototype for ophthalmic surgical support has been developed. The final intention of this prototype is to be an evaluation tool for guided suture and as an outcome diminish the postoperative astigmatism. Methods The system consists of hand held ring with 36 infrared LEDs, that is to be projected onto the lachrymal film of the cornea. The image is reflected back through the optics of the ocular microscope and its distortion from the original circular shape is evaluated by developed software. It provides keratometric and circularity measurements during surgery in order to guide the surgeon for uniformity in suturing. Results The system is able to provide up to 23D of astigmatism (32D - 55D range) and is ± 0.25D accurate. It has been tested in 14 volunteer patients intraoperative and has been compared to a commercial keratometer Nidek Oculus Hand-held corneal topographer. The correlation factors are 0.92 for the astigmatism and 0.97 for the associated axis. Conclusion The system is potentially efficient for guiding the surgeon on uniformity of suturing, presenting preliminary data indicating an important decrease on the residual astigmatism, from an average of 8D - for patients not submitted to the prototype guidance - to 1.4D - for patients who have actually been submitted to the prototype guidance - after the first 24 hours post-surgery and in the subsequent weeks. It also indicates that the surgeon should achieve circularity greater or equal to 98% in order to avoid postoperative astigmatisms over 1D. Trial Registration Trial registration number: CAAE - 0212.0.004.000-09.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background The objective of this study was to investigate the effects of the Brazilian Scaptotrigona sp propolis, a widely used folk medicine, in corneal wound healing and inflammation. Methods Corneal epithelial defects of 1 mm in diameter were made in the right eyes of Wistar male adult rats by cauterization with silver nitrate sticks. Subsequently, they were divided in two groups (n = 40 rats/group): Brazilian propolis (BP) group was topically treated with a microemulsion containing 1% Brazilian propolis; vehicle (VH) group received the same formulation without propolis. The epithelial defect area was photographed and measured at t = 0 (wound induction), and after 12, 24, 48 and 120 h of treatment. The inflammatory response was evaluated based on counting of neutrophils. Epithelial regeneration rates were determined based on Ki-67 expression in basal epithelial cells. Comparisons were made using the Kruskal-Wallis and the Mann–Whitney U test. Results The BP group presented both smaller epithelial defect areas at 12, 24 and 48 h and fewer corneal infiltrating neutrophils at 24 and 48 h (P < 0.01) than the VH group. These effects were associated with more pervasive Ki-67 staining in the BP group at 12 and 24 h (P < 0.05). Conclusions Topically applied BP accelerated wound healing and reduced the inflammatory response to silver nitrate-induced corneal alkali burns in rats.