14 resultados para Conventional evaluation

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite their generality, conventional Volterra filters are inadequate for some applications, due to the huge number of parameters that may be needed for accurate modelling. When a state-space model of the target system is known, this can be assessed by computing its kernels, which also provides valuable information for choosing an adequate alternate Volterra filter structure, if necessary, and is useful for validating parameter estimation procedures. In this letter, we derive expressions for the kernels by using the Carleman bilinearization method, for which an efficient algorithm is given. Simulation results are presented, which confirm the usefulness of the proposed approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New technologies and sterilization agents for heat-sensitive materials are under intense investigation. Plasma sterilization, an atoxic low-temperature substitute for conventional sterilization, uses various gases that are activated by an electrical discharge, generating reactive species that promote lethality in microorganisms. Here, assays were performed using pure O-2 and O-2 + H2O2 mixture gas plasmas against a standard load of Bacillus atrophaeus spores inoculated on glass carriers inside PVC catheters. The sterilization efficiency was studied as a function of plasma system (reactive ion etching or inductively coupled plasma), biological monitor lumen diameter, gas, radio frequency power, and sub-lethal exposition time. After sterilization, the biological monitors were disassembled and the surviving bacteria were grown in trypticase soy broth using the most probable number technique. Plasma antimicrobial activity depended on the catheter's internal diameter and radio frequency powers. The N-2 + H2O2 mixture exhibited higher microbial efficacy than pure N-2 in both plasma systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Subsurface drip irrigation that uses an emitter protection system to avoid its clogging by roots and soil particles may be viable compared to a conventional system. The objective of this work was to evaluate the performance of a system with emitter protection, and to compare the results with a system that uses a conventional emitter for subsurface drip irrigation. In the system with protection an inexpensive materials polyethylene hose, microtube, connector, and a dripper to control the flow rate were used; and, in the conventional system a commercial emitter was used. After 12 months of evaluation, the system with protector showed good performance, with relative average flow rate of 0.97 and 0.98 in pots with and without crop, respectively, showing no clogging problems and lower cost. In conventional system relative flow rate of 0.51 and 0.98 were observed in pots with and without crop, respectively, also clogging degree by roots of 49.22%, and emitters with soil inside was observed. Thus, the use of emitter with protection presented feasibility for subsurface drip irrigation, under conditions used in this research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of a photodegradable tape was evaluated on 'Valencia' sweet orange nursery trees budded both on Rangpur lime and Swingle citrumelo in a greenhouse in Bebedouro-SP, Brazil, from September to November 2009. On both rootstocks three wrapping procedures were evaluated: i) conventional polyethylene tape wrapped around the bud eye; ii) photodegradable tape wrapped around the bud eye, and iii) photodegradable tape wrapped around the graft junction without covering the bud eye. The following variables were measured: time spent for wrapping, percentage of bud sprouting, length and stem diameter of the scion shoot, and percentage of commercially valuable nursery trees. The trial was conducted following a randomized complete block design, with six treatments, four replications and 12 trees per plot. The use of photodegradable tape, with or without covering the bud eye, anticipated bud sprouting; despite of the longer time spent with wrapping when the photodegradable tape was used. Plants grafted onto the less vigorous Swingle citrumelo rootstock showed lower bud sprout percentages when the bud eye was covered with the photodegradable tape.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of standard reference electrodes, such as Ag/AgCl or saturated calomel electrodes, in potentiometric and amperometric studies involving miniaturized electrochemical systems, or those operating under positive hydraulic pressure, is often impractical. Placement of the reference electrode in the direct vicinity of the working electrode is often prohibited by the dimensions or layout of the electrochemical cell, while the alternative strategy of locating the reference electrode in a separate compartment often leads to electrolyte leakage and contamination of the system. In the present study, we have investigated the functionality of a pseudoreference electrode comprising a platinum wire, one end of which was maintained in intimate contact with the internal solution of an Ag/AgCl reference electrode while the other was connected, via a BNC connector, to a platinum probe located within the electrochemical cell. Linear and cyclic voltammetric studies, involving both aqueous and nonaqueous electrolytes, were carried out using the pseudoreference electrode and an electrochemical cup-type cell with three electrodes or an electrochemical flow reactor. In all cases, the functionality of the Pt//Ag/AgCl system was similar to that of a conventional Ag/AgCl reference electrode. Variations in the electrolyte did not alter the potential or voltammetric profile recorded when using the pseudoreference system, although peak currents were generally improved and potential values shifted by approximately +350 mV in comparison with the Ag/AgCl electrode, therefore, the system pseudoreference can be applied in any electrochemical system due to the constant potential difference. It is concluded that the pseudoreference electrode can be used with advantage to obtain potentiometric and amperometric measurements in both simple and complex electrochemical systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The presence and survival of microorganisms on toothbrush bristles might play a role on the etiology of oral infections. The aim of this in vitro study was to evaluate the presence of bacterial contamination on new toothbrushes before oral contact. Materials and methods: Forty toothbrushes from five different manufacturers were used in this experimental study. Each manufacturer was divided according to conventional local of obtaining: industry, drugstore, market, and perfumery. The toothbrush heads were completely immersed into tubes containing 5.0 mL of sterile peptonated water (dilution 1:10). A group of eight tubes containing the sterile solution was used as control. After 21 days of anaerobic incubation, occurrence of contamination was visually evaluated and confirmed by light microscopy. Results: Bacterial growth in the medium, indicative of bristles contamination, was found in a total of 19 out of 40 samples (47.5%) evaluated: 6 out of 14 samples (42.85%) from industry group, 4 out of 8 samples (50.0%) from drugstore, 5 out of 10 samples (50.0%) from market, and 4 out of 8 samples (50.0%) from perfumery. Only the toothbrushes with bristles coated with chlorhexidine did not show contamination. The Gram-negative sporulating bacilli were the most prevalent form recovered. Conclusions: Except for chlorhexidine group, bacterial growth was observed in all groups evaluated irrespective local of obtaining. Microsc. Res. Tech., 2012. (c) 2011 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the Vickers hardness of different acrylic resins for denture bases with and without the addition of glass fibres. Background: It has been suggested that different polymerisation methods, as well as the addition of glass fibre (FV) might improve the hardness of acrylic. Materials and methods: Five types of acrylic resin were tested: Vipi Wave (VW), microwave polymerisation; Vipi Flash (VF), auto-polymerisation; Lucitone (LT), QC20 (QC) and Vipi Cril (VC), conventional heat-polymerisation, all with or without glass fibre reinforcement (GFR) and distributed into 10 groups (n = 12). Specimens were then submitted to Vickers hardness testing with a 25-g load for 30 s. All data were submitted to ANOVA and Tukey's HSD test. Results: A significant statistical difference was observed with regard to the polymerisation method and the GFR (p < 0.05). Without the GFR, the acrylic resin VC presented the highest hardness values, and VF and LT presented the lowest. In the presence of GFR, VC resin still presented the highest Vickers hardness values, and VF and QC presented the lowest. Conclusions: The acrylic resin VC and VW presented higher hardness values than VF and QC resins. Moreover, GFR increased the Vickers hardness of resins VW, VC and LT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The cost-effectiveness of a modified supervised toothbrushing program was compared to a conventional program. A total of 284 five-year-old children presenting at least one permanent molar with emerged/sound occlusal surface participated. In the control group, oral health education and dental plaque dying followed by toothbrushing with fluoride dentifrice was carried outfour times per year. With the test group, children also underwent professional cross-brushing on surfaces of first permanent molar rendered by a dental assistant five times per year. Enamel/dentin caries were recorded on buccal, occlusal and lingual surfaces of permanent molars for a period of 18 months. The incidence density (ID) ratio was estimated using Poisson's regression model. The ID was 50% lower among boys in the test group (p = 0.016). The cost of the modified program was US$ 1.79 per capita. The marginal cost-effectiveness ratio among boys was US$ 6.30 per avoided carie. The modified supervised toothbrushing program was shown to be cost-effective in the case of boys.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

International Journal of Paediatric Dentistry 2012; 22: 459466 Aim. This in vitro study aimed to test the performance of fluorescence-based methods in detecting occlusal caries lesions in primary molars compared to conventional methods. Design. Two examiners assessed 113 sites on 77 occlusal surfaces of primary molars using three fluorescence devices: DIAGNOdent (LF), DIAGNOdent pen (LFpen), and fluorescence camera (VistaProof-FC). Visual inspection (ICDAS) and radiographic methods were also evaluated. One examiner repeated the evaluations after one month. As reference standard method, the lesion depth was determined after sectioning and evaluation in stereomicroscope. The area under the ROC curve (Az), sensitivity, specificity, and accuracy of the methods were calculated at enamel (D1) and dentine caries (D3) lesions thresholds. The intra and interexaminer reproducibility were calculated using the intraclass correlation coefficient (ICC) and kappa statistics. Results. At D1, visual inspection presented higher sensitivities (0.970.99) but lower specificities (0.180.25). At D3, all the methods demonstrated similar performance (Az values around 0.90). Visual and radiographic methods showed a slightly higher specificity (values higher than 0.96) than the fluorescence based ones (values around 0.88). In general, all methods presented high reproducibility (ICC higher than 0.79). Conclusions. Although fluorescence-based and conventional methods present similar performance in detecting occlusal caries lesions in primary teeth, visual inspection alone seems to be sufficient to be used in clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Advances in information technology have been widely used in teaching health care professionals. The use of multimedia resources may be important for clinical learning and we are not aware of previous reports using such technology in respiratory physical therapy education. Objectives: Our approach was to evaluate a conventional bronchial hygiene techniques (BHTs) course with an interactive online environment, including multimedia resources. Methods: Previous developed audiovisual support material comprised: physiology, physiopathology and BHTs, accessible to students through the Internet in conjunction with BHTs classes. Two groups of students were compared and both attended regular classes: the on-line group (n=8) received access to online resources, while the control group (n=8) received conventional written material. Student's performance was evaluated before and after the course. Results: A preliminary test (score 0 to 10) was applied before the beginning of the course, showing that the initial knowledge of both groups was comparable [online, 6.75 (SD=0.88) vs. control, 6.125 (SD=1.35); p>0.05]. Two weeks after the end of the course, a second test showed that the online group performed significantly better than the control group [respectively, 7.75 (SD=1.28) vs. 5.93 (SD=0.72); p>0.05]. Conclusions: The use of a multimedia online resource had a positive impact on student's learning in respiratory therapy field in which instrumental and manual resources are often used and can be explored using this technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaluation of outcomes after aesthetic surgery still is a challenge in plastic surgery. The evaluation frequently is based on subjective criteria. This study used a new clinical grading scale to evaluate aesthetic results for plastic surgeries to the abdomen. The method scores each of the following five parameters: volume of subcutaneous tissue, contour, excess of skin, aspect of the navel, and quality of the scar on the abdominal wall. The scale options are 0 (poor), 1 (fair), and 2 (good), and the total rate can range from 0 to 10. The study included 40 women ages 18-53 years. Of these 40 women, 20 underwent traditional abdominoplasty, and 20 had liposuction alone. Preoperatively and at least 1 year later, photographic results were analyzed and scored by three independent plastic surgeons. In the abdominoplasty group, the average grade rose from 2.9 +/- A 0.4 to 6.8 +/- A 0.4 postoperatively. In the liposuction group, the average grade was 5.3 +/- A 0.5 preoperatively and 7.7 +/- A 0.4 postoperatively. In both groups, the average postoperative grade was significantly higher than the preoperative grade. The mean scores for groups A and L were significantly different, demonstrating that the scale was sensitive in identifying different anatomic abnormalities in the abdomen. The rating scale used for the aesthetic evaluation of the abdomen was effective in the analysis of two different procedures: conventional abdominoplasty and liposuction. Abdominoplasty provided the greater gain according to a comparison of the pre- and postoperative scores.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: A growing interest to preserve teeth into the mouth by patients resulted in the increasing number of endodontic retreatments, and when these happen, many different types of irritants are extruded through the foramen. Objective: This study analyzed in vitro the amount of debris extruded through the foramen using four instrumentation techniques during endodontic retreatment. Material and methods: Forty mesial-buccal roots of first molars were selected, instrumented with anatomical diameter up to size #30 ISO file and then obturated with gutta-percha and grossman sealer by lateral condensation. After, they were separated and randomly allocated into four groups with 10 teeth each for the endodontic retreatment procedure: G1 – conventional technique + solvent, G2 – conventional technique without solvent, G3 – ProTaper retreatment + solvent, G4 – ProTaper retreatment without solvent. In all groups, gutta-percha in the coronal portion was removed by using size 1-3 Gates Glidden drills. All teeth were irrigated with distilled water. The debris extruded through the foramen were collected and weighed by an analytical balance. Results: Group 4 had the lowest average for material extrusion through the foramen followed by groups 2, 3 and 1. When Tukey test for statistical analysis was applied, no significant difference among groups were found (p = 0.5664). Conclusion: We conclude that all instrumentation techniques used in this study produced debris which goes beyond the foramen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to evaluate in vivo the bonding of metallic orthodontic brackets with different adhesive systems. MATERIAL AND METHODS: Twenty patients (10.5-15.1 years old) who had sought corrective orthodontic treatment at a University Orthodontic Clinic were evaluated. Brackets were bonded from the right second premolar to the left second premolar in the upper and lower arches using: Orthodontic Concise, conventional Transbond XT, Transbond XT without primer, and Transbond XT associated with Transbond Plus Self-etching Primer (TPSEP). The 4 adhesive systems were used in all patients using a split-mouth design; each adhesive system was used in one quadrant of each dental arch, so that each group of 5 patients received the same bonding sequence. Initial archwires were inserted 1 week after bracket bonding. The number of bracket failures for each adhesive system was quantified over a 6-month period. RESULTS: The number of debonded brackets was: 8- Orthodontic Concise, 2- conventional Transbond XT, 9- Transbond XT without primer, and 1- Transbond XT + TPSEP. By using the Kaplan-Meier methods, statistically significant differences were found between the materials (p=0.0198), and the Logrank test identified these differences. Conventional Transbond XT and Transbond XT + TPSEP adhesive systems were statistically superior to Orthodontic Concise and Transbond XT without primer (p<0.05). There was no statistically significant difference between the dental arches (upper and lower), between the dental arch sides (right and left), and among the quadrants. CONCLUSIONS: The largest number of bracket failures occurred with Orthodontic Concise and Transbond XT without primer systems and few bracket failures occurred with conventional Transbond XT and Transbond XT+TPSEP. More bracket failures were observed in the posterior region compared with the anterior region.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The treatment of hemorrhoidal disease (HD) by conventional hemorrhoidectomy is associated with significant morbidity, mainly represented by the postoperative pain and the late return to daily activities. Doppler-guided hemorrhoid artery ligation (DGHAL) is a minimal-invasive surgical treatment for HD that has been used as an alternative method in order to reduce these inconveniences. OBJECTIVE: To analyze the initial results of the DGHAL technique associated with rectal mucopexy in the treatment of HD. METHODS:Forty-two patients with stage I, III and IV hemorrhoids who were submitted to DGHAL were analyzed from December 2010 to August 2011. Eleven patients (26%) were stage II; 21 (50%), stage III; and 10 (24%), stage IV HD. All patients were operated by the same surgeon under spinal anesthesia and using the same equipment and technique to perform the procedure. The 42 patients underwent ligation of six arterial branches followed by rectal mucopexia by uninterrupted suture. Nine patients needed concomitant removal of perianal skin tag. In the postoperative, the following parameters were evaluated: pain, tenesmus, bleeding, itching, prolapse, mucus discharge and recurrence. The mean postoperative follow-up lasted four months (one to nine months). RESULTS: Tenesmus was the most common postoperative complaint for 85.7% of patients followed by pain, in 28.6%, perianal burning, in 12.3%, mucus discharge and perianal hematoma in 4.7%. Two patients had severe postoperative bleeding and required surgical haemostasis, one of which needed blood transfusion. Ninety-five percent of the patients declared to be satisfied with the method. CONCLUSION: Even though DGHAL has complications similar to those of other surgical methods, its results present less postoperative pain, allowing faster recovery and return to work. Studies with more cases and a longer follow-up are still necessary to assess the late recurrence.