10 resultados para Computer-Based Training System

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This qualitative, exploratory, descriptive study was performed with the objective of understanding the perception of the nurses working in medical-surgical units of a university hospital, regarding the strategies developed to perform a pilot test of the PROCEnf-USP electronic system, with the purpose of computerizing clinical nursing documentation. Eleven nurses of a theoretical-practical training program were interviewed and the obtained data were analyzed using the Content Analysis Technique. The following categories were discussed based on the references of participative management and planned changes: favorable aspects for the implementation; unfavorable aspects for the implementation; and expectations regarding the implementation. According to the nurses' perceptions, the preliminary use of the electronic system allowed them to show their potential and to propose improvements, encouraging them to become partners of the group manager in the dissemination to other nurses of the institution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives To evaluate the learning, retention and transfer of performance improvements after Nintendo Wii Fit (TM) training in patients with Parkinson's disease and healthy elderly people. Design Longitudinal, controlled clinical study. Participants Sixteen patients with early-stage Parkinson's disease and 11 healthy elderly people. Interventions Warm-up exercises and Wii Fit training that involved training motor (shifts centre of gravity and step alternation) and cognitive skills. A follow-up evaluative Wii Fit session was held 60 days after the end of training. Participants performed a functional reach test before and after training as a measure of learning transfer. Main outcome measures Learning and retention were determined based on the scores of 10 Wii Fit games over eight sessions. Transfer of learning was assessed after training using the functional reach test. Results Patients with Parkinson's disease showed no deficit in learning or retention on seven of the 10 games, despite showing poorer performance on five games compared with the healthy elderly group. Patients with Parkinson's disease showed marked learning deficits on three other games, independent of poorer initial performance. This deficit appears to be associated with cognitive demands of the games which require decision-making, response inhibition, divided attention and working memory. Finally, patients with Parkinson's disease were able to transfer motor ability trained on the games to a similar untrained task. Conclusions The ability of patients with Parkinson's disease to learn, retain and transfer performance improvements after training on the Nintendo Wii Fit depends largely on the demands, particularly cognitive demands, of the games involved, reiterating the importance of game selection for rehabilitation purposes. (C) 2012 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study is to retrospectively report the results of interventions for controlling a vancomycin-resistant enterococcus (VRE) outbreak in a tertiary-care pediatric intensive care unit (PICU) of a University Hospital. After identification of the outbreak, interventions were made at the following levels: patient care, microbiological surveillance, and medical and nursing staff training. Data were collected from computer-based databases and from the electronic prescription system. Vancomycin use progressively increased after March 2008, peaking in August 2009. Five cases of VRE infection were identified, with 3 deaths. After the interventions, we noted a significant reduction in vancomycin prescription and use (75% reduction), and the last case of VRE infection was identified 4 months later. The survivors remained colonized until hospital discharge. After interventions there was a transient increase in PICU length-of-stay and mortality. Since then, the use of vancomycin has remained relatively constant and strict, no other cases of VRE infection or colonization have been identified and length-of-stay and mortality returned to baseline. In conclusion, we showed that a bundle intervention aiming at a strict control of vancomycin use and full compliance with the Hospital Infection Control Practices Advisory Committee guidelines, along with contact precautions and hand-hygiene promotion, can be effective in reducing vancomycin use and the emergence and spread of vancomycin-resistant bacteria in a tertiary-care PICU.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To analyze the effects of a water-based exercise program on peak torque (PT) and rate of torque development (RTD) during maximal voluntary ballistic isometric contractions of the lower limb muscles and the performance of a number of functional tests in the elderly. Method: Thirty-seven elderly were randomly assigned to water-based training (3 d/wk for 12 wk) or a control group. Extensor and flexor PT and RTD of the ankle, knee, and hip joints and functional tests were evaluated before and after training. Results: PT increased after training for the hip flexors (18%) and extensors (40%) and the plantar-flexor (42%) muscles in the water-based group. RTD increased after training for the hip-extensor (10%), knee-extensor (11%), and ankle plantar-flexor (27%) muscles in the water-based group. Functional tests also improved after training in the water-based group (p < .05). Conclusion: The water-based program improved PT and RTD and functional performance in the elderly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes a new design for a paper-based electrochemical system for flow injection analysis. Capillary wicking facilitates a gravity-driven flow of buffer solution continuously through paper and nitrocellulose, from a buffer reservoir at one end of the device to a sink at the other. A difference in height between the reservoir and the sink leads to a continuous and constant flow. The nitrocellulose lies horizontally on a working electrode, which consists of a thin platinum layer deposited on a solid support. The counter and reference electrodes are strategically positioned upstream in the buffer reservoir. A simple pipetting device was developed for reliable application of (sub)microliter volumes of sample without the need of commercial micropipets; this device did not damage the nitrocellulose membrane. Demonstration of the system for the determination of the concentration of glucose in urine resulted in a noninvasive, quantitative assay that could be used for diagnosis and monitoring of diabetes. This method does not require disposable test strips, with enzyme and electrodes, that are thrown away after each measurement Because of its low cost, this system could be used in medical environments that are resource-limited.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surveillance Levels (SLs) are categories for medical patients (used in Brazil) that represent different types of medical recommendations. SLs are defined according to risk factors and the medical and developmental history of patients. Each SL is associated with specific educational and clinical measures. The objective of the present paper was to verify computer-aided, automatic assignment of SLs. The present paper proposes a computer-aided approach for automatic recommendation of SLs. The approach is based on the classification of information from patient electronic records. For this purpose, a software architecture composed of three layers was developed. The architecture is formed by a classification layer that includes a linguistic module and machine learning classification modules. The classification layer allows for the use of different classification methods, including the use of preprocessed, normalized language data drawn from the linguistic module. We report the verification and validation of the software architecture in a Brazilian pediatric healthcare institution. The results indicate that selection of attributes can have a great effect on the performance of the system. Nonetheless, our automatic recommendation of surveillance level can still benefit from improvements in processing procedures when the linguistic module is applied prior to classification. Results from our efforts can be applied to different types of medical systems. The results of systems supported by the framework presented in this paper may be used by healthcare and governmental institutions to improve healthcare services in terms of establishing preventive measures and alerting authorities about the possibility of an epidemic.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

System thinking allows companies to use subjective constructs indicators like recursiveness, cause-effect relationships and autonomy to performance evaluation. Thus, the question that motivates this paper is: Are Brazilian companies searching new performance measurement and evaluation models based on system thinking? The study investigates models looking for system thinking roots in their framework. It was both exploratory and descriptive based on a multiple four case studies strategy in chemical sector. The findings showed organizational models have some characteristics that can be related to system thinking as system control and communication. Complexity and autonomy are deficiently formalized by the companies. All data suggest, inside its context, that system thinking seems to be adequate to organizational performance evaluation but remains distant from the management proceedings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage. Material and Methods: The restorative systems Adper Single Bond 2/Filtek Z350 (ASB), Clearfil SE Bond/Z350 (CF), Adper SE Plus/Z350 (ASEP) and P90 Adhesive System/Filtek P90 (P90) were applied on flat dentin surfaces of 20 third molars (n=5). The restored teeth were sectioned perpendicularly to the bonding interface to obtain sticks (0.8 mm2) to be tested after 24 hours (24 h) and 6 months (6 m) of water storage, in a universal testing machine at 0.5 mm/min. The data was analyzed via two-way Analysis of Variance/Bonferroni post hoc tests at 5% global significance. Results: Overall outcomes did not indicate a statistical difference for the resin systems (p=0.26) nor time (p=0.62). No interaction between material × time was detected (p=0.28). Mean standard-deviation in MPa at 24 h and 6 m were: ASB 31.38 (4.53) and 30.06 (1.95), CF 34.26 (3.47) and 32.75 (4.18), ASEP 29.54 (4.14) and 33.47 (2.47), P90 30.27 (2.03) and 31.34 (2.19). Conclusions: The silorane-based system showed a similar performance to methacrylate-based materials on dentin. All systems were stable in terms of bond strength up to 6 month of water storage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este estudo qualitativo e exploratório-descritivo busca compreender a percepção de enfermeiras de unidades clínico-cirúrgicas de um hospital universitário referente às estratégias desenvolvidas para o teste piloto do sistema eletrônico PROCEnf-USP, visando à informatização da documentação clínica de enfermagem. Onze enfermeiras participantes de um programa de capacitação teórico-prático foram entrevistadas e os dados obtidos foram analisados por meio da Técnica de Análise de Conteúdo. As categorias aspectos favoráveis à implementação; aspectos desfavoráveis à implementação e expectativas na implementação foram discutidas na perspectiva dos referenciais da administração participativa e da mudança planejada. Com base na percepção das enfermeiras, o uso preliminar do sistema eletrônico lhes possibilitou evidenciar suas potencialidades e propor melhorias, o que as incentivou a tornarem-se parceiras do grupo gestor na divulgação junto aos demais enfermeiros da instituição.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the new active absorption wave basin, named Hydrodynamic Calibrator (HC), constructed at the University of São Paulo (USP), in the Laboratory facilities of the Numerical Offshore Tank (TPN). The square (14 m 14 m) tank is able to generate and absorb waves from 0.5 Hz to 2.0 Hz, by means of 148 active hinged flap wave makers. An independent mechanical system drives each flap by means of a 1HP servo-motor and a ball-screw based transmission system. A customized ultrasonic wave probe is installed in each flap, and is responsible for measuring wave elevation in the flap. A complex automation architecture was implemented, with three Programmable Logic Computers (PLCs), and a low-level software is responsible for all the interlocks and maintenance functions of the tank. Furthermore, all the control algorithms for the generation and absorption are implemented using higher level software (MATLAB /Simulink block diagrams). These algorithms calculate the motions of the wave makers both to generate and absorb the required wave field by taking into account the layout of the flaps and the limits of wave generation. The experimental transfer function that relates the flap amplitude to the wave elevation amplitude is used for the calculation of the motion of each flap. This paper describes the main features of the tank, followed by a detailed presentation of the whole automation system. It includes the measuring devices, signal conditioning, PLC and network architecture, real-time and synchronizing software and motor control loop. Finally, a validation of the whole automation system is presented, by means of the experimental analysis of the transfer function of the waves generated and the calculation of all the delays introduced by the automation system.