4 resultados para Canto popular
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Este texto busca apresentar a trajetória da gravadora paulistana Chantecler, que, ao longo dos anos 60 e 70, teve um papel fundamental na formação de artistas ligados a segmentos então menosprezados pelas grandes gravadoras, especialmente o sertanejo, a música romântica tradicional e a música regional. Além disso, o texto traz ainda uma reflexão acerca do processo de estratificação do consumo de música popular que se verificou no país a partir dos anos 60 e, nesse contexto, do papel que passou a ser ocupado pelas gravadoras nacionais diante das empresas internacionais (majors) que estavam se instalando no país
Resumo:
In this work, the reduction reaction of paraquat herbicide was used to obtain analytical signals using electrochemical techniques of differential pulse voltammetry, square wave voltammetry and multiple square wave voltammetry. Analytes were prepared with laboratory purified water and natural water samples (from Mogi-Guacu River, SP). The electrochemical techniques were applied to 1.0 mol L-1 Na2SO4 solutions, at pH 5.5, and containing different concentrations of paraquat, in the range of 1 to 10 mu mol L-1, using a gold ultramicroelectrode. 5 replicate experiments were conducted and in each the mean value for peak currents obtained -0.70 V vs. Ag/AgCl yielded excellent linear relationships with pesticide concentrations. The slope values for the calibration plots (method sensitivity) were 4.06 x 10(-3), 1.07 x 10(-2) and 2.95 x 10(-2) A mol(-1) L for purified water by differential pulse voltammetry, square wave voltammetry and multiple square wave voltammetry, respectively. For river water samples, the slope values were 2.60 x 10(-3), 1.06 x 10(-2) and 3.35 x 10(-2) A mol(-1) L, respectively, showing a small interference from the natural matrix components in paraquat determinations. The detection limits for paraquat determinations were calculated by two distinct methodologies, i.e., as proposed by IUPAC and a statistical method. The values obtained with multiple square waves voltammetry were 0.002 and 0.12 mu mol L-1, respectively, for pure water electrolytes. The detection limit from IUPAC recommendations, when inserted in the calibration curve equation, an analytical signal (oxidation current) is smaller than the one experimentally observed for the blank solution under the same experimental conditions. This is inconsistent with the definition of detection limit, thus the IUPAC methodology requires further discussion. The same conclusion can be drawn by the analyses of detection limits obtained with the other techniques studied.
Resumo:
OBJETIVO: Verificar a presença de alteração do estado de ansiedade das mães de crianças hospitalizadas com a audição de canto Gregoriano. MÉTODOS: Pesquisa descritiva, exploratória, correlacional com análise quantitativa, quase experimental. A coleta dos dados foi realizada no período de julho de 2009 a fevereiro de 2010. A amostra inicial foi de 71 mães e destas 28 concluíram todas as etapas da pesquisa. RESULTADOS: O uso do canto Gregoriano diminuiu o estado de ansiedade das mães de crianças hospitalizadas em um hospital pediátrico de atenção quaternária acomodadas em quartos individuais. CONCLUSÃO: É necessário investigar os possíveis efeitos do canto Gregoriano em outros ambientes do hospital e em outras formas de acomodação do cliente.