Resumo:
STUDY DESIGN: Clinical measurement. OBJECTIVE: To translate and culturally adapt the Lower Extremity Functional Scale (LEFS) into a Brazilian Portuguese version, and to test the construct and content validity and reliability of this version in patients with knee injuries. BACKGROUND: There is no Brazilian Portuguese version of an instrument to assess the function of the lower extremity after orthopaedic injury. METHODS: The translation of the original English version of the LEFS into a Brazilian Portuguese version was accomplished using standard guidelines and tested in 31 patients with knee injuries. Subsequently, 87 patients with a variety of knee disorders completed the Brazilian Portuguese LEES, the Medical Outcomes Study 36-Item Short-Form Health Survey, the Western Ontario and McMaster Universities Osteoarthritis Index, and the International Knee Documentation Committee Subjective Knee Evaluation Form and a visual analog scale for pain. All patients were retested within 2 days to determine reliability of these measures. Validation was assessed by determining the level of association between the Brazilian Portuguese LEFS and the other outcome measures. Reliability was documented by calculating internal consistency, test-retest reliability, and standard error of measurement. RESULTS: The Brazilian Portuguese LEES had a high level of association with the physical component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.82), the Western Ontario and McMaster Universities Osteoarthritis Index (r = 0.87), the International Knee Documentation Committee Subjective Knee Evaluation Form (r = 0.82), and the pain visual analog scale (r = -0.60) (all, P<.05). The Brazilian Portuguese LEES had a low level of association with the mental component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.38, P<.05). The internal consistency (Cronbach alpha = .952) and test-retest reliability (intraclass correlation coefficient = 0.957) of the Brazilian Portuguese version of the LEES were high. The standard error of measurement was low (3.6) and the agreement was considered high, demonstrated by the small differences between test and retest and the narrow limit of agreement, as observed in Bland-Altman and survival-agreement plots. CONCLUSION: The translation of the LEFS into a Brazilian Portuguese version was successful in preserving the semantic and measurement properties of the original version and was shown to be valid and reliable in a Brazilian population with knee injuries. J Ort hop Sports Phys Ther 2012;42(11):932-939, Epub 9 October 2012. doi:10.2519/jospt.2012.4101
Resumo:
Studies have shown anatomical and functional differences between men and women with respect to the mouth, pharynx, upper esophageal sphincter, and esophagus. The aim of this investigation was to analyze the influence of gender, body mass index (BMI), age, and orofacial anthropometric measurements on the intraoral maximum volume capacity for liquid. The investigation included asymptomatic subjects, 56 females and 44 males, aged 19-53 years. The volunteers sucked water through a straw up to the maximum tolerated oral volume, which was greater in men (71.2 +/- A 15.0 ml) than in women (55.4 +/- A 13.4 ml). Age, BMI, height, and number of teeth had no influence on the intraoral tolerated volume. Anthropometric orofacial measurements were greater in men than in women. In individuals with height between 1.66 and 1.89 m, anthropometric orofacial measurements were greater in men than in women, and the tolerated intraoral volume was greater in men than in women. There was a positive correlation between orofacial measurements and intraoral maximum volume. In conclusion, men have the capacity to place a larger volume of water inside their mouth than women. This observation is associated with higher anthropometric orofacial measures, but not with age, number of teeth, height, or BMI.
Resumo:
There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1A degrees and 15` check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays` electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (+/- 3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 +/- A 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.
Resumo:
Purpose: The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT) for measuring the buccal bone volume around dental implants. Materials and methods: Three to six implants were inserted into the anterior maxilla of eight skulls, depending on the availability of bone, and after this, the CBCT was performed. By means of CBCT image, measurements of the bone wall at three points of the implant were obtained, analyzed and compared with those obtained in the plaster skull casting. Results: The results showed that for the three points of the implants, no statistically significant difference in the measurements was obtained from the plaster model and CBCT images. Conclusions: CBCT can be a useful tool for assessing buccal bone volume along the implant. To cite this article:?Shiratori LN, Marotti J, Yamanouchi J, Chilvarquer I, Contin I, Tortamano-Neto P. Measurement of buccal bone volume of dental implants by means of cone-beam computed tomography.?Clin. Oral Impl. Res. 23, 2012; 797804.?doi: 10.1111/j.1600-0501.2011.02207.x
Resumo:
Objective. To compare the clinical, demographic, and serologic characteristics and the treatment of patients diagnosed with ankylosing spondylitis (AS) from Europe (EU) and Latin America (LA). Methods. We included 3439 patients from national registries: the Spanish Registry of Spondyloarthritis (REGISPONSER), the Belgian registry (ASPECT), and the Latin American Registry of Spondyloarthropathies (RESPONDIA). We selected patients with diagnosis of AS who met the modified New York classification criteria. Demographic, clinical, disease activity, functional, and metrological measurement data were recorded. Current treatment was recorded. The population was classified into 2 groups: patients with disease duration < 10 years and those with disease duration >= 10 years. A descriptive and comparative analysis of variables of both groups was carried out. Results. There were 2356 patients in EU group and 1083 in LA group. Prevalence of HLA-B27 was 71% in LA group and 83% in EU group (p < 0.001). We found a greater frequency of peripheral arthritis and enthesitis (p < 0.001) in the LA population; prevalence of arthritis was 57% in LA and 42% in EU, and for enthesitis, 54% and 38%. Except for treatment with anti-tumor necrosis factor (anti-TNF), the use of nonsteroidal antiinflammatory drugs (NSAID), corticosteroids, and disease-modifying antirheumatic drugs (DMARD), and the association of anti-TNF and methotrexate use showed a significant difference (p < 0.001) in the 2 populations. Conclusion. The principal differences in the clinical manifestations of patients with AS from EU and LA were the greater frequency of peripheral arthritis and enthesitis in LA group, the higher percentage of HLA-B27 in EU group, and the form of treatment, with a greater use of NSAID, steroids, and DMARD in the LA group. (First Release Nov 15 2012; J Rheumatol 2012;39:2315-20; doi:10.3899/jrheum.110687)
Resumo:
Lodenafil carbonate is a new phosphodiesterase Type 5 (PDE5) inhibitor used in treatment of erectile dysfunction. Objective: The present study was conducted to evaluate the safety, tolerability, and pharmacokinetics of lodenafil carbonate after administering ascending (1 - 100 mg) single oral doses to healthy male volunteers (n = 33). Methods: The study was an open-label, dose-escalation, Phase I clinical trial involving the administration of single oral doses of lodenafil carbonate. Lodenafil carbonate was administered sequentially, escalating in single doses of 1 mg - 100 mg with a washout period of at least 1 week between each dose. The progression to the next dose was allowed after clinical and laboratory exams, Ambulatory Monitoring of Arterial Pressure (AMAP) without relevant clinical modifications and adverse events without clinical relevancy. Blood samples were collected at pre-dose, 0.25, 0.5, 0.75, 1, 1.25, 1.5, 1.75, 2, 2.5, 3, 3.5, 4, 4.5, 5, 6, 7, 8, 10, 12, 14, 16, 20 and 24 h post-dosing. Plasma samples for measurement of lodenafil carbonate and lodenafil were analyzed by liquid chromatography coupled to tandem mass spectrometry. Results: No serious adverse events were observed, and none of the subjects discontinued the study due to intolerance. The AMAP measurements, clinical and laboratory exams and ECG revealed no significant changes even at higher doses. Lodenafil carbonate was not detected in any samples, indicating that it acts as a prodrug. The mean lodenafil pharmacokinetic parameters for t(max) and t(1/2) were 1.6 (+/- 0.4) h and 3.3 (+/- 1.1) h, respectively. This study demonstrated that lodenafil carbonate was well tolerated and showed a good safety profile in healthy male volunteers.