4 resultados para Bench marks

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents the offorts to calculate the geoid model for Brazil. It is limited by 6 degrees N and 35 degrees S in latitude and 30 degrees W and 75 degrees W in longitude. The terrestrial gravity data for the continent have been updated by means of the most recent surveys in Brazil and in the neighbour countries. The complete Bouguer and Helmert gravity anomalies have been derived through the Canadian package SHGEO. The short wavelength component was estimated via FFT. The geopotential model EGM2008 was used as a reference field restricted to degree and order 150. The model was validated over 844 GPS observations on Bench Marks of the spirit leveling network. The height anomalies plus a topography dependent correction term derived from EGM2008 (degree 2190 and order 2159), GO_CONS_GCF_2_DIR_R2 (degree and order 240), GOCO02S (degree and order 250), EIGEN 51C (degree and order 359) and EIGEN 6C (degree and order 1420), geoidal height derived from MAPGEO2004 (old official geoid model in Brazil) have also been compared to the GPS points on Bench Marks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. The purpose of the study was to investigate the relationship between the total volume of load lifted (TVLL) and the rating of perceived exertion (RPE) measures during different resistance training (RT) schemes using the bench press exercise. Methods. The present study was divided into two experiments. In the first experiment, 18 healthy men performed three different RT schemes: a strength oriented scheme (SS), a muscular endurance oriented scheme (ES) and a hypertrophy oriented scheme (HS). TVLL was calculated for each scheme. Mean-RPE and session-RPE were assessed. In the second experiment, 23 men performed two resistance exercise bouts at different intensities (50 %-1RM and 75%-1RM) with matched TVLL. Mean-RPE and session-RPE were also assessed. Results. SS and HS showed higher TVLL and greater RPE scores as compared to ES (P<0.05). No significant difference was observed between SS and HS. It was verified significant positive correlations between TVLL and session-RPE (SS r=0.63, HS r=0.64, ES r=0.56; P<0.05), and between mean-RPE and TVLL (SS r=0.55, HS r=0.52, ES r=0.47; P<0.05) for all schemes. No differences were observed for mean-RPE, session-RPE and TVLL between the 50%-1RM and 75%1RM. Significant positive relationships between TVLL and session-RPE (50 %-1RM r=0.61, 75 %-1RM r=0.66; p<0.05) and between TVLL and mean-RPE (50 %-1RM r=0.51, 75%1RM r=0.49; P<0.05) were observed. Conclusion. The results of this study have shown that the TVLL in RT influences RPE measures. These findings corroborates the existence of a relationship between total work performed (external training load) and perception of effort (internal training load).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ferreira, SLA, Panissa, VLG, Miarka, B, and Franchini, E. Postactivation potentiation: effect of various recovery intervals on bench press power performance. J Strength Cond Res 26(3): 739-744, 2012-Postactivation potentiation (PAP) is a strategy used to improve performance in power activities. The aim of this study was to determine if power during bench press exercise was increased when preceded by 1 repetition maximum (1RM) in the same exercise and to determine which time interval could optimize PAP response. For this, 11 healthy male subjects (age, 25 +/- 4 years; height, 178 +/- 6 cm; body mass, 74 +/- 8 kg; bench press 1RM, 76 +/- 19 kg) underwent 6 sessions. Two control sessions were conducted to determine both bench press 1RM and power (6 repetitions at 50% 1RM). The 4 experimental sessions were composed of a 1RM exercise followed by power sets with different recovery intervals (1, 3, 5, and 7 minutes), performed on different days, and determined randomly. Power values were measured via Peak Power equipment (Cefise, Nova Odessa, Sao Paulo, Brazil). The conditions were compared using an analysis of variance with repeated measures, followed by a Tukey test. The significance level was set at p < 0.05. There was a significant increase in PAP in concentric contractions after 7 minutes of recovery compared with the control and 1-minute recovery conditions (p < 0.05). Our results indicated that 7 minutes of recovery has generated an increase in PAP in bench press and that such a strategy could be applied as an interesting alternative to enhance the performance in tasks aimed at increasing upper-body power performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Automated weaning modes are available in some mechanical ventilators, but no studies compared them hitherto. We compared the performance of 3 automated modes under standard and challenging situations. Methods: We used a lung simulator to compare 3 automated modes, adaptive support ventilation (ASV), mandatory rate ventilation (MRV), and Smartcare, in 6 situations, weaning success, weaning failure, weaning success with extreme anxiety, weaning success with Cheyne-Stokes, weaning success with irregular breathing, and weaning failure with ineffective efforts. Results: The 3 modes correctly recognized the situations of weaning success and failure, even when anxiety or irregular breathing were present but incorrectly recognized weaning success with Cheyne-Stokes. MRV incorrectly recognized weaning failure with ineffective efforts. Time to pressure support (PS) stabilization was shorter for ASV (1-2 minutes for all situations) and MRV (1-7 minutes) than for Smartcare (8-78 minutes). ASV had higher rates of PS oscillations per 5 minutes (4-15), compared with Smartcare (0-1) and MRV (0-12), except when extreme anxiety was present. Conclusions: Smartcare, ASV, and MRV were equally able to recognize weaning success and failure, despite the presence of anxiety or irregular breathing but performed incorrectly in the presence of Cheyne-Stokes. PS behavior over the time differs among modes, with ASV showing larger and more frequent PS oscillations over the time. Clinical studies are needed to confirm our results. (C) 2012 Elsevier Inc. All rights reserved.