4 resultados para Application methods

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The methods used for evaluating wound dimensions, especially the chronic ones, are invasive and inaccurate. The fringe projection technique with phase shift is a non-invasive, accurate and low-cost optical method. Objective: The aim is to validate the technique through the determination of dimensions of objects of known topography and with different geometries and colors to simulate the wounds and tones of skin color. Taking into account the influence of skin wound optical factors, the technique will be used to evaluate actual patients’ wound dimensions and to study its limitations in this application. Methods: Four sinusoidal fringe patterns, displaced ¼ of period each, were projected onto the objects surface. The object dimensions were obtained from the unwrapped phase map through the observation of the fringe deformations caused by the object topography and using phase shift analysis. An object with simple geometry was used for dimensional calibration and the topographic dimensions of the others were determined from it. After observing the compatibility with the data and validating the method, it was used for measuring the dimensions of real patients’ wounds. Results and Conclusions: The discrepancies between actual topography and dimensions determined with Fringe Projection Technique and for the known object were lower than 0.50 cm. The method was successful in obtaining the topography of real patient’s wounds. Objects and wounds with sharp topographies or causing shadow or reflection are difficult to be evaluated with this technique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Combining data from multiple analytical platforms is essential for comprehensive study of the molecular phenotype (metabotype) of a given biological sample. The metabolite profiles generated are intrinsically dependent on the analytical platforms, each requiring optimization of instrumental parameters, separation conditions, and sample extraction to deliver maximal biological information. An in-depth evaluation of extraction protocols for characterizing the metabolome of the hepatobiliary fluke Fasciola hepatica, using ultra performance liquid chromatography and capillary electrophoresis coupled with mass spectroscopy is presented. The spectrometric methods were characterized by performance, and metrics of merit were established, including precision, mass accuracy, selectivity, sensitivity, and platform stability. Although a core group of molecules was common to all methods, each platform contributed a unique set, whereby 142 metabolites out of 14,724 features were identified. A mixture design revealed that the chloroform:methanol:water proportion of 15:59:26 was globally the best composition for metabolite extraction across UPLC-MS and CE-MS platforms accommodating different columns and ionization modes. Despite the general assumption of the necessity of platform-adapted protocols for achieving effective metabotype characterization, we show that an appropriately designed single extraction procedure is able to fit the requirements of all technologies. This may constitute a paradigm shift in developing efficient protocols for high-throughput metabolite profiling with more-general analytical applicability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, the reduction reaction of paraquat herbicide was used to obtain analytical signals using electrochemical techniques of differential pulse voltammetry, square wave voltammetry and multiple square wave voltammetry. Analytes were prepared with laboratory purified water and natural water samples (from Mogi-Guacu River, SP). The electrochemical techniques were applied to 1.0 mol L-1 Na2SO4 solutions, at pH 5.5, and containing different concentrations of paraquat, in the range of 1 to 10 mu mol L-1, using a gold ultramicroelectrode. 5 replicate experiments were conducted and in each the mean value for peak currents obtained -0.70 V vs. Ag/AgCl yielded excellent linear relationships with pesticide concentrations. The slope values for the calibration plots (method sensitivity) were 4.06 x 10(-3), 1.07 x 10(-2) and 2.95 x 10(-2) A mol(-1) L for purified water by differential pulse voltammetry, square wave voltammetry and multiple square wave voltammetry, respectively. For river water samples, the slope values were 2.60 x 10(-3), 1.06 x 10(-2) and 3.35 x 10(-2) A mol(-1) L, respectively, showing a small interference from the natural matrix components in paraquat determinations. The detection limits for paraquat determinations were calculated by two distinct methodologies, i.e., as proposed by IUPAC and a statistical method. The values obtained with multiple square waves voltammetry were 0.002 and 0.12 mu mol L-1, respectively, for pure water electrolytes. The detection limit from IUPAC recommendations, when inserted in the calibration curve equation, an analytical signal (oxidation current) is smaller than the one experimentally observed for the blank solution under the same experimental conditions. This is inconsistent with the definition of detection limit, thus the IUPAC methodology requires further discussion. The same conclusion can be drawn by the analyses of detection limits obtained with the other techniques studied.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We investigate the strong magnetic and gravity anomalies of the Goias Alkaline Province (GAP), a region of Late Cretaceous alkaline magmatism along the northern border of the Parana Basin, Brazil. The alkaline complexes (eight of which are present in outcrops, two others inferred from magnetic signals) are characterized by a series of small intrusions forming almost circular magnetic and gravimetric anomalies varying from -4000 to +6000 nT and from -10 to +40 mGal, respectively. We used the Aneuler method and Analytical Signal Amplitude to obtain depth and geometry for mapped sources from the magnetic anomaly data. These results were used as the reference models in the 3D gravity inversion. The 3D inversion results show that the alkaline intrusions have depths of 10-12 km. The intrusions in the northern GAP follow two alignments and have different sizes. In the anomaly magnetic map, dominant guidelines correlate strongly with the extensional regimes that correlate with the rise of alkaline magmatism. The emplacement of these intrusions marks mechanical discontinuities and zones of weakness in the upper crust. According to the 3D inversion results, those intrusions are located within the upper crust (from the surface to 18 km depth) and have spheres as the preferable geometry. Such spherical shapes are more consistent with magmatic chambers instead of plug intrusions. The Registro do Araguaia anomaly (similar to 15 by 25 km) has a particular magnetic signature that indicates that the top is deeper than 1500 m. North of this circular anomaly are lineaments with structural indices indicating contacts on their edges and dikes/sills in the interiors. Results of 3D inversion of magnetic and gravity data suggest that the Registro do Araguaia is the largest body in the area, reaching 18 km depth and indicating a circular layered structure. (C) 2011 Elsevier Ltd. All rights reserved.