10 resultados para ARRAY BIOSENSOR
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
We report an efficient alternative to obtain recessed microelectrodes device on gold electrode surface, in which mixed self-assembled monolayer of long and short carbon alkanethiol chains was used for this purpose. Development of the modified electrodes included the chemical adsorption of 11-mercaptoundecanoic acid and 2-mercaptoethanol solution, as well as their mixtures, on gold surface, resulting in the final mixed self-assembled monolayer configuration. For comparison, the electrochemical performance of self-assembled monolayer of 11-mercaptoundecanoic acid. 3-mercaptopropionic acid, 4-mercapto-1-butanol and 6-mercapto-1-hexanol modified electrodes was also investigated. It was verified that, in the mixed self-assembled monolayer, the 11-mercaptoundecanoic acid acts as a barrier for electron transfer while the short alkanethiol chair is deposited in an island-like shape through which electrons can be freely transferred to ions in solution, allowing electrochemical reactions to occur. The performance of the modified electrodes toward microelectrode behavior was investigated via cyclic voltammetry and electrochemical impedance spectroscopy measurements using [Fe(CN)(6)](3-/4-) redox couple as a probe. In this case, sigmoidal voltammetric responses were obtained, very similar to those observed for microelectrodes. Such behavior reinforces the proposition of electron transfer through the short alkanethiol chain layer and surface blockage by the long chain one. Electrochemical impedance results allowed calculated the mean radius value of each microelectrode disks of 3.8 mu m with about 22 mu m interval between them. The microelectrode environment provided by the mixed self-assembled monolayer can be conveniently used to provide an efficient catalytic conversion in biosensing applications. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Changes in the oceanic heat storage (HS) can reveal important evidences of climate variability related to ocean heat fluxes. Specifically, long-term variations in HS are a powerful indicator of climate change as HS represents the balance between the net surface energy flux and the poleward heat transported by the ocean currents. HS is estimated from sea surface height anomaly measured from the altimeters TOPEX/Poseidon and Jason 1 from 1993 to 2006. To characterize and validate the altimeter-based HS in the Atlantic, we used the data from the Pilot Research Moored Array in the Tropical Atlantic (PIRATA) array. Correlations and rms differences are used as statistical figures of merit to compare the HS estimates. The correlations range from 0.50 to 0.87 in the buoys located at the equator and at the southern part of the array. In that region the rms differences range between 0.40 and 0.51 x 10(9) Jm(-2). These results are encouraging and indicate that the altimeter has the precision necessary to capture the interannual trends in HS in the Atlantic. Albeit relatively small, salinity changes can also have an effect on the sea surface height anomaly. To account for this effect, NCEP/GODAS reanalysis data are used to estimate the haline contraction. To understand which dynamical processes are involved in the HS variability, the total signal is decomposed into nonpropagating basin-scale and seasonal (HS(l)) planetary waves, mesoscale eddies, and small-scale residual components. In general, HS(l) is the dominant signal in the tropical region. Results show a warming trend of HS(l) in the past 13 years almost all over the Atlantic basin with the most prominent slopes found at high latitudes. Positive interannual trends are found in the halosteric component at high latitudes of the South Atlantic and near the Labrador Sea. This could be an indication that the salinity anomaly increased in the upper layers during this period. The dynamics of the South Atlantic subtropical gyre could also be subject to low-frequency changes caused by a trend in the halosteric component on each side of the South Atlantic Current.
Resumo:
A Co-doped silica film was deposited on the surface of a Si(100) wafer and isothermally annealed at 750 degrees C to form spherical Co nanoparticles embedded in the silica film and a few atomic layer thick CoSi2 nanoplatelets within the wafer. The structure, morphology, and spatial orientation of the nanoplatelets were characterized. The experimental results indicate that the nanoplatelets exhibit hexagonal shape and a uniform thickness. The CoSi2 nanostructures lattice is coherent with the Si lattice, and each of them is parallel to one of the four planes belonging to the {111} crystallographic form of the host lattice. (C) 2012 American Institute of Physics. [doi:10.1063/1.3683493]
Resumo:
This paper describes a CMOS implementation of a linear voltage regulator (LVR) used to power up implanted physiological signal systems, as it is the case of a wireless blood pressure biosensor. The topology is based on a classical structure of a linear low-dropout regulator. The circuit is powered up from an RF link, thus characterizing a passive radio frequency identification (RFID) tag. The LVR was designed to meet important features such as low power consumption and small silicon area, without the need for any external discrete components. The low power operation represents an essential condition to avoid a high-energy RF link, thus minimizing the transmitted power and therefore minimizing the thermal effects on the patient's tissues. The project was implemented in a 0.35-mu m CMOS process, and the prototypes were tested to validate the overall performance. The LVR output is regulated at 1 V and supplies a maximum load current of 0.5 mA at 37 degrees C. The load regulation is 13 mV/mA, and the line regulation is 39 mV/V. The LVR total power consumption is 1.2 mW.
Resumo:
The effect of the room temperature ionic liquid (1-butyl-2,3-dimethylimidazolium tetrafluoroborate ([BMMI][BF4])) on the immobilization of glucose oxidase (GOx) was studied. The electrochemical performance of biosensors prepared following different protocols indicated a beneficial effect of the ionic liquid on the analytical parameters. The chemical interaction between GOx, [BMMI][BF4] and glutaraldehyde was investigated using UV-visible spectroscopy (UV-vis) and circular dichroism (CD). Structural changes of the biomolecule were observed to depend on the method used for the immobilization. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The search for bioactive molecules to be employed as recognition elements in biosensors has stimulated researchers to pore over the rich Brazilian biodiversity. In this sense, we introduce the use of natural cashew gum (Anacardium occidentale L) as an active biomaterial to be used in the form of layer-by-layer films, in conjunction with phthalocyanines, which were tested as electrochemical sensors for dopamine detection. We investigated the effects of chemical composition of cashew gum from two different regions of Brazil (Piaui and Ceara states) on the physico-chemical characteristics of these nanostructures. The morphology of the nanostructures containing cashew gum was studied by atomic force microscopy which indicates that smooth films punctuated by globular features were formed that showed low roughness values. The results indicate that, independent of the origin, cashew gum stands out as an excellent film forming material with potential application in nanobiomedical devices as electrochemical sensors. (c) 2012 Elsevier B.V. All rights reserved.
Resumo:
A sensitive electrochemical acetylcholinesterase (AChE) biosensor was successfully developed on polyaniline (PANI) and multi-walled carbon nanotubes (MWCNTs) core-shell modified glassy carbon electrode (GC), and used to detect carbamate pesticides in fruit and vegetables (apple, broccoli and cabbage). The pesticide biosensors were applied in the detection of carbaryl and methomyl pesticides in food samples using chronoamperometry (CA). The GC/MWCNT/PANI/AChE biosensor exhibited detection limits of 1.4 and 0.95 mu mol L-1, respectively, for carbaryl and methomyl. These detection limits were below the allowable concentrations set by Brazilian regulation standards for the samples in which these pesticides were analysed. Reproducibility and repeatability values of 2.6% and 3.2%, respectively, were obtained in the conventional procedure. The proposed biosensor was successfully applied in the determination of carbamate pesticides in cabbage, broccoli and apple samples without any spiking procedure. The obtained results were in full agreement with those from the HPLC procedure. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Fleury Group
Resumo:
The association between anisotropic magnetoresistive (AMR) sensor and AC biosusceptometry (ACB) to evaluate gastrointestinal motility is presented. The AMR-ACB system was successfully characterized in a bench-top study, and in vivo results were compared with those obtained by means of simultaneous manometry. Both AMR-ACB and manometry techniques presented high temporal cross correlation between the two periodicals signals (R = 0.9 +/- 0.1; P < 0.05). The contraction frequencies using AMR-ACB were 73.9 +/- 7.6 mHz and using manometry were 73.8 +/- 7.9 mHz during the baseline (r = 98, p < 0.05). The amplitude of contraction using AMR-ACB was 396 +/- 108 mu T.s and using manometry were 540 +/- 198 mmHg.s during the baseline. The amplitudes of signals for AMR-ACB and manometric recordings were similarly increased to 86.4% and 89.3% by neostigmine, and also decreased to 27.2% and 21.4% by hyoscine butylbromide in all animals, respectively. The AMR-ACB array is nonexpensive, portable, and has high-spatiotemporal resolution to provide helpful information about gastrointestinal tract.
Resumo:
We present a new Ultra Wide Band (UWB) Timed- Array Transmitter System with Beamforming capability for high-resolution remote acquisition of vital signals. The system consists of four identical channels, where each is formed of a serial topology with three modules: programmable delay circuit (PDC or τ), a novel UWB 5th Gaussian Derivative order pulse generator circuit (PG), and a planar Vivaldi antenna. The circuit was designed using 0.18μm CMOS standard process and the planar antenna array was designed with filmconductor on Rogers RO3206 substrate. Spice simulations results showed the pulse generation with 104 mVpp amplitude and 500 ps width. The power consumption is 543 μW, and energy consumption 0.27 pJ per pulse using a 2V power supply at a pulse repetition rate (PRR) of 100 MHz. Electromagnetic simulations results, using CST Microwave (MW) Studio 2011, showed the main lobe radiation with a gain maximum of 13.2 dB, 35.5º x 36.7º angular width, and a beam steering between 17º and -11º for azimuthal (θ) angles and 17º and -18º for elevation (φ) angles at the center frequency of 6 GHz