9 resultados para Óxidos metálico
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Silver containing heavy metal oxide glasses and glass ceramics of the system WO3-SbPO4-PbO-AgCl with different AgCl contents have been prepared and their thermal, structural and optical properties characterized. Glass ceramics containing metallic silver nanoparticles have been prepared by annealing glass samples at temperatures above the glass transition and analyzed by transmission electron microscopy and energy dispersive X-ray microanalysis. The presence of the metallic clusters has been also confirmed by the observation of a surface plasmon resonimce band in the visible range. Cyclic voltammetric measurements indicated the presence of metallic silver into the glasses, even before to perform the thermal treatment.
Resumo:
INTRODUÇÃO: O tratamento endovascular dos aneurismas da aorta abdominal tem revolucionado o tratamento dessa afecção, em decorrência das baixas taxas de morbidade e mortalidade. Apesar dos avanços tecnológicos ocorridos nas endopróteses, ainda existem limitações anatômicas para o emprego da técnica. Este estudo teve por objetivo avaliar os resultados imediatos do tratamento de pacientes portadores de aneurisma da aorta abdominal com anatomia complexa com uma endoprótese de segunda geração. MÉTODOS: Estudo observacional, prospectivo, não-randomizado, realizado em um único centro, em uma série de pacientes submetidos a tratamento endovascular de aneurismas da aorta abdominal infrarrenais complexos, com prótese com arcabouço metálico disposta em anéis (Anaconda - Vascutek, Terumo, Inchinnan, Escócia). Foram avaliados as características clínicas e angiográficas, o sucesso técnico, o sucesso terapêutico, a morbidade e a mortalidade, e a taxa de reintervenção perioperatória. RESULTADOS: Foram analisados, no período de fevereiro de 2010 a dezembro de 2011, 108 pacientes consecutivos portadores de aneurisma da aorta, dos quais 16 eram portadores de aneurisma da aorta abdominal com anatomia complexa tratados com a prótese Anaconda . A média de idade foi de 76 + 7 anos e 75% eram do sexo masculino. Houve sucesso técnico em 94% e êxito terapêutico em 75% dos casos. Ocorreu um óbito no pós-operatório. As complicações perioperatórias mais prevalentes foram sangramento da ferida operatória (2/16) e embolia periférica (2/16). Foram necessárias reintervenções em 12,5% dos pacientes durante o seguimento. CONCLUSÕES: Neste estudo, a segunda geração da endoprótese Anaconda foi efetiva e apresenta resultados imediatos satisfatórios no tratamento do aneurisma da aorta abdominal infrarrenal de anatomia complexa.
Resumo:
OBJETIVO: Determinar a taxa de sucesso da broncoscopia flexível como primeira opção na remoção de corpos estranhos das vias aéreas em adultos. MÉTODOS: Estudo retrospectivo de todos os pacientes adultos (acima de 18 anos) com aspiração de corpo estranho submetidos a broncoscopia no Hospital das Clínicas, Faculdade de Medicina da Universidade de São Paulo, em São Paulo (SP). RESULTADOS: A amostra foi constituída por 40 pacientes adultos, com média de idade de 52 anos (variação: 18-88 anos). A mediana do tempo de permanência do corpo estranho na via aérea foi de 15 dias (variação: 12 h a 10 anos). Todos os pacientes foram submetidos primeiramente a broncoscopia flexível diagnóstica. A retirada do corpo estranho por meio de broncoscopia flexível foi bem-sucedida em 33 dos pacientes (82,5%). Em 1 paciente, um objeto metálico alojado na árvore brônquica distal requereu o uso de fluoroscopia. Seis pacientes (15%) foram submetidos a broncoscopia rígida devido a dispneia induzida por corpo estranho traqueal, em 2, e porque o corpo estranho era muito grande para as pinças flexíveis, em 4. A broncoscopia falhou em apenas 1 paciente, que portanto necessitou de broncotomia. CONCLUSÕES: Embora a broncoscopia rígida seja considerada o padrão ouro na remoção de corpos estranhos na via aérea, nossa experiência mostrou que a broncoscopia flexível pode ser utilizada segura e eficientemente no diagnóstico e tratamento de pacientes adultos estáveis.
Resumo:
This paper presents the classification of 110 copper ore samples from Sossego Mine, based on X-ray diffraction and cluster analysis. The comparison based on the position and the intensity of the diffracted peaks allowed the distinction of seven ore types, whose differences refer to the proportion of major minerals: quartz, feldspar, actinolite, iron oxides, mica and chlorite. There was a strong correlation between the grouping and the location of the samples in Sequeirinho and Sossego orebodies. This relationship is due to different types and intensities of hydrothermal alteration prevailing in each body, which reflect the mineralogical composition and thus the X-ray diffractograms of samples.
Resumo:
Dimensional analysis was employed to develop a predictive formula for the terminal velocity for a magnet dropped down a metallic tube. In this particular application, the technique succeeded in generating the same formula theoretically derived and that has been published by others. The analysis thus presented suggests other applications that can be developed for motivating in the use of the technique.
Resumo:
Este trabalho descreve a preparação e caracterização do híbrido celulose/fosfato de nióbio hidratado (Cel/NbOPO4.nH2O) utilizando como material de partida a celulose branqueada de bagaço de cana-de-açúcar e o nióbio metálico. O híbrido foi preparado por dois métodos: denominados métodos I e II. O método I consistiu na dissolução do nióbio metálico em solução de ácido fluorídrico/nítrico (100:10), com tempo de contato de 16 horas entre a celulose branqueada do bagaço de cana-de-açúcar e a solução ácida. Adicionou-se a essa solução ácido fosfórico para precipitação do material. O método II foi semelhante, com proporções diferentes da solução ácida fluorídrico/nítrico (160/100), sem tempo de contato da celulose com a solução ácida. Os métodos I e II utilizaram as seguintes proporções de cel/ Nb2O5.nH2O: (10:10);(10:6) e (10:2). Os materiais preparados pelos métodos I e II foram caracterizados por difração de raios X (DRX), termogravimetria (TG/DTG) e microscopia eletrônica de varredura (MEV). Observou-se aumento do índice do grau de cristalinidade e mudanças na morfologia dos materiais preparados.
Resumo:
Esse trabalho consiste na caracterização do resíduo de mármore, lama fina de aciaria e borra de alumínio, para averiguar a viabilidade técnica da utilização de tais resíduos na dessulfuração e desfosforação de ferro-gusa líquido. A caracterização desses resíduos foi feita através de análises químicas, granulométricas, difração de raios X e microscopia eletrônica de varredura (MEV) com micro análise por Espectroscopia por Energia Dispersiva de Raios X (EDS). A lama fina de aciaria apresenta um teor de FeO de 84,90%, o resíduo de mármore apresentou um teor de 61,5% de CaO e 33,9% de MgO e a borra de alumínio apresentou 36,5% de Al metálico e 62% de Al2O3. A granulometria do resíduo de mármore apresentou um tamanho de grão médio igual 42,810 µm. Já, na borra de alumínio, o tamanho médio foi de 101,803 µm. A lama fina de aciaria LD apresentou, em torno de 54,7% de sua granulometria, entre 0,15 e 0,075mm. Esses resultados apontam para a viabilidade técnica da utilização desses materiais na dessulfuração e desfosforação do ferro-gusa.
Resumo:
PURPOSE: To evaluate the in vitro fracture resistance of roots with glass-fiber and metal dowels with different designs. METHODS: Fifty-endodontically treated maxillary central incisors were embedded in acrylic resin. Ten of them received only the coronary preparation, and the remaining forty were embedded (except for 4mm of the cervical area) after removing the clinical crowns. Specimens were divided into five groups (n=10): control (teeth with only coronary preparation), cylindrical cast dowel, conical cast dowel, cylindrical glass-fiber dowel and conical glass-fiber dowel. Specimens were subjected to an increasing compressive load (N) until fracture. RESULTS: ANOVA indicated significant difference (P<.05) among the groups, and the Tukey-Kramer´s test identified these differences. The control group (867±243 N) presented the highest values and was statistically similar to cylindrical glass-fiber dowel group (711±180 N). There is no significant difference among the metal dowel cylindrical (435±245 N) or conical (585±164 N) group and conical glass-fiber dowel (453±112 N). Cylindrical glass-fiber dowel (711±180 N) and conical cast dowel and core (585±164 N) groups had intermediate values and did not differ from each other. CONCLUSIONS: Cylindrical glass fiber dowels represent a viable alternative to the cast-metal dowel cylindrical or conical. Cylindrical glass fiber dowels also increase endodontically treated incisors' resistance to fracture.
Resumo:
Este artigo foi escrito para mostrar aos alunos de graduação em Física e Engenharia como estimar as correntes de Foucault. Inicialmente fazemos uma breve análise das condições de contorno entre dois meios com diferentes parâmetros ε, μ e σ, que devem ser obedecidas tanto por campos eletromagnéticos estáticos quanto dependentes do tempo. Em seguida, usando as equações de Maxwell calculamos as “correntes de Foucault”, ou “eddy currents”, que surgem em um condutor plano metálico (paramagnético ou diamagnético) quando sobre ele é aplicado um campo magnético B(t) variável no tempo, gerado por um solenoide longo de seção reta circular.