23 resultados para neutron detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports measurements of atmospheric neutrino and antineutrino interactions in the MINOS Far Detector, based on 2553 live-days (37.9 kton-years) of data. A total of 2072 candidate events are observed. These are separated into 905 contained-vertex muons and 466 neutrino-induced rock-muons, both produced by charged-current nu(mu) and (nu) over bar (mu) interactions, and 701 contained-vertex showers, composed mainly of charged-current nu(e) and (nu) over bar (e) interactions and neutral-current interactions. The curvature of muon tracks in the magnetic field of the MINOS Far Detector is used to select separate samples of nu(mu) and (nu) over bar (mu) events. The observed ratio of (nu) over bar (mu) to v(mu) events is compared with the Monte Carlo ( MC) simulation, giving a double ratio of R((nu) over bar/nu)data/R(nu) over bar/nu MC = 1.03 +/- 0.08(stat) +/- 0.08(syst). The v(mu) and (nu) over bar (mu) data are separated into bins of L/E resolution, based on the reconstructed energy and direction of each event, and a maximum likelihood fit to the observed L/E distributions is used to determine the atmospheric neutrino oscillation parameters. This fit returns 90% confidence limits of |Delta m(2)| = (1.9 +/- 0.4) x 10(-3) eV(2) and sin(2)2 theta > 0.86. The fit is extended to incorporate separate nu(mu) and (nu) over bar mu oscillation parameters, returning 90% confidence limits of |Delta m(2)| - |Delta(m) over bar (2)| = 0.6(-0.8)(+2.4) x 10(-3) eV(2) on the difference between the squared-mass splittings for neutrinos and antineutrinos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The C-13(O-18,O-16)C-15 reaction has been studied at 84 MeV incident energy. The ejectiles have been detected at forward angles and C-15 excitation energy spectra have been obtained up to about 20 MeV. Several known bound and resonant states of C-15 have been identified together with two unknown structures at 10.5 MeV (FWHM = 2.5 MeV) and 13.6 MeV (FWHM = 2.5 MeV). Calculations based Oil the removal of two uncorrelated neutrons from the projectile describe a significant part of the continuum observed in the energy spectra. In particular the structure at 10.5 MeV is dominated by a resonance of C-15 near the C-13 + n + n threshold. Similar structures are found in nearby nuclei such as C-14 and Be-11. (c) 2012 Elsevier BM. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brazil holds the second largest population of domestic dogs in the world, with 33 million dogs, only behind the United States. The annual consumption of dog food in the country is 1.75 million tons, corresponding to the World's sixth in trade turnover. Dog food is supposed to be a complete and balanced diet, formulated with high quality ingredients. All nutrients and minerals required for an adequate nutrition of dogs are added to the formulation to ensure longevity and welfare. In this context, the present study aimed at assessing the chemical composition of dry dog foods commercialized in Brazil. Thirty-four samples were acquired in the local market of Piracicaba and analyzed by instrumental neutron activation analysis (INAA) to determine the elements As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Se, U, and Zn. In general, the concentrations of Ca, Fe, K, Na, and Zn complied with the values required by the Association of American Feed Control Officials (AAFCO). To evaluate the safety of dog food commercialized in Brazil, further investigation is necessary to better understand the presence of toxic elements found in this study, i.e. Sb and U. INAA was useful for the screening analysis of different types and brands of dry dog foods for the determination of both essential and toxic elements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The LA-MC-ICP-MS method applied to U-Pb in situ dating is still rapidly evolving due to improvements in both lasers and ICP-MS. To test the validity and reproducibility of the method, 5 different zircon samples, including the standard Temora-2, ranging in age between 2.2 Ga and 246 Ma, were dated using both LA-MC-ICP-MS and SHRIMP. The selected zircons were dated by SHRIMP and, after gentle polishing, the laser spot was driven to the same site or on the same zircon phase with a 213 nm laser microprobe coupled to a multi-collector mixed system. The data were collected with a routine spot size of 25 μm and, in some cases, of 15 and 40 μm. A careful cross-calibration using a diluted U-Th-Pb solution to calculate the Faraday reading to counting rate conversion factors and the highly suitable GJ-1 standard zircon for external calibrations were of paramount importance for obtaining reliable results. All age results were concordant within the experimental errors. The assigned age errors using the LA-MC-ICP-MS technique were, in most cases, higher than those obtained by SHRIMP, but if we are not faced with a high resolution stratigraphy, the laser technique has certain advantages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the planning, implementation, and initial results of the first planned move of the default position of spectra on the Hubble Space Telescope's Cosmic Origins Spectrograph (COS) Far Ultraviolet (FUV) cross-delay line detector. This was motivated by the limited amount of charge that can be extracted from the microchannel plate due to gain sag at any one position. Operations at a new location began on July 23, 2012, with a shift of the spectrum by +3.5"(corresponding to ~ 41 pixels or ~ 1 mm) in a direction orthogonal to the spectral dispersion. Operation at this second "lifetime position" allows for spectra to be collected which are not affected by detector artifacts and loss of sensitivity due to gain sag. We discuss programs designed to enable operations at the new lifetime position; these include determinations of operational high voltage, measuring walk corrections and focus, confirming spectrum placement and aperture centering, and target acquisition performance. We also present results related to calibration of the new lifetime position, including measurements of spectral resolution and wavelength calibration, flux and flat field calibration, carryover of time-dependent sensitivity monitoring, and operations with the Bright Object Aperture (BOA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A systematic study of the response of different nuclei to the (18O, 16O) two-neutron transfer reaction at 84 MeV incident energy was pursued at the INFN-LNS in Catania (Italy). The experiments were performed using several solid targets from light (9Bc, 11 B, 12,13C, 16O, 28Si) to heavier ones (58,64Ni, 120Sn, 208Pb). The 16O ejectiles were detected at forward angles by the MAGNEX magnetic spectrometer and identified without the need of time of flight measurements. Exploiting the large momentum (≈ 25%) and angular (50 msr) acceptance of the spectrometer, energy spectra were obtained with a relevant yield up to about 20 MeV excitation energy. A common feature of the light nuclei spectra is the strong population of states with well known configuration of two-particle over a core and the appearance of unknown resonant structures in the continuum. These latter can reveal the excitation of a collective mode connected with the transfer of a pair. For the heavier nuclei as 66Ni a completely different behaviour is observed indicating the presence of more dissipative processes in the reaction mechanisms that hide the spectroscopic information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed characterization of a X-ray Si(Li) detector was performed to obtain the energy dependence of efficiency in the photon energy range of 6.4 - 59.5 keV. which was measured and reproduced by Monte Carlo (MC) simulations. Significant discrepancies between MC and experimental values were found when lhe manufacturer parameters of lhe detector were used in lhe simulation. A complete Computerized Tomagraphy (CT) detector scan allowed to find the correct crystal dimensions and position inside the capsule. The computed efficiencies with the resulting detector model differed with the measured values no more than 10% in most of the energy range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doppler Broadening Spectroscopy of the large Ge crystal of an HPGe detector was perforrned using positrons from pair production of 6.13 MeV ϒ-rays from the 19F(p,αϒ) 16O reaction. Two HPGe detectors facing opposite sides of the Ge crystal acting as target provided both coincidence and singles spectra. Changes in the shape of the annihilation peak were observed when the high voltage applied to the target detector was switched on or off, amounting to somewhat less than 20% when the areas of equivalent energy intervals in the corresponding normalized spectra are compared.