22 resultados para leaf-to-air vapor pressure deficit
Resumo:
Membranes of Poly(2,5-benzimidazole) (ABPBI), prepared by polycondensation in polyphosphoric acid, were characterized from the fuel cell application point of view: mechanical properties of the membranes for different acid doping levels, thermal stability, permeability for the different gases/vapors susceptible of use in the cell (hydrogen, oxygen, methanol and ethanol), electro-osmotic water drag coefficient, oxidation stability to hydroxyl radicals, phosphoric acid leaching rate and, finally, in-plane membrane conductivity. ABPBI membranes presented an excellent thermal stability, above 500 degrees C in oxygen, suitable mechanical properties for high phosphoric acid doping levels, a low methanol and ethanol limiting permeation currents, and oxygen permeability compared to Nafion membranes, and a low phosphoric acid leaching rate when exposed to water vapor. On the contrary, hydrogen permeation current was higher than that of Nafion, and the chemical stability was very limited. Membrane conductivity achieved 0.07 S cm(-1) after equilibration with a humid environment. Fuel cell tests showed reasonable good performances, with a maximum power peak of 170 mW cm(-2) for H-2/air at 170 degrees C operating under a humidified hydrogen stream, 39.9 mW cm(-2) for CH3OH/O-2 at 200 degrees C for a methanol/water weight ratio of 1: 2, and 31.5 mW cm(-2) for CH3CH2OH/O-2 at the same conditions than for methanol. (C) 2012 The Electrochemical Society. [DOI: 10.1149/2.014207jes] All rights reserved.
Resumo:
We evaluated the effects of air-drying distance and bond surface area on the shear bond strength of a 2-step etch-and-rinse adhesive. A total of 120 bovine anterior teeth were equally divided into 6 main groups based on bonding surface area. The main groups were divided into sub-groups (n = 5) according to air-drying distance. The shear strength was determined using a universal testing machine at a crosshead speed of 0.5 mm/min. The averaged results were subjected to two-way ANOVA and Tukey's test (alpha = 0.05). Two-way ANOVA testing identified no significant cross-product interactions (p > 0.05), but the main factors of area (p < 0.0001) and air-drying distance (p < 0.00001) significantly affected the mean bond strength. Shorter air-drying distances improved bond strength, and increased surface area decreased the bond strength.
Resumo:
The synthesis of nickel catalysts for industrial applications is relatively simple; however, nickel oxidation is usually difficult to avoid, which makes it challenging to optimize catalytic activities, metal loadings, and high-temperature activation steps. A robust, oxidation-resistant and very active nickel catalyst was prepared by controlled decomposition of the organometallic precursor [bis(1,5-cyclooctadiene)nickel(0)], Ni(COD)(2), over silica-coated magnetite (Fe3O4@SiO2). The sample is mostly Ni(0), and surface oxidized species formed after exposure to air are easily reduced in situ during hydrogenation of cyclohexene under mild conditions recovering the initial activity. This unique behavior may benefit several other reactions that are likely to proceed via Ni heterogeneous catalysis.
Resumo:
Shear bond strength between Ni-Cr alloy bonded to a ceramic substrate Introduction: The aim of this study was to evaluate the shear bond strength between a Ni-Cr alloy and a ceramic system submitted or not to thermocycling. Materials and methods: Forty-eight cylinder blocks of Ni-Cr with 3.0 mm diameter by 4.0 mm hight and 48 disc-shaped specimens (7.0 mm in diameter by 2.0 mm thick) composed of ceramic were prepared. The Ni-Cr cylinder blocks were randomised in two groups of 24 specimens each. One group was submitted to air-particle abrasion (sandblasting) with 50 mu m Al2O3 (0.4-0.7 MPa) during 20 s, and the other group was submitted to mechanical retentions with carbide burrs. Each group was subdivided into other two groups (n = 12), submitted or not to thermocycling (500 cycles, 5-55 degrees C). The cylinder blocks were bonded to the disc-shaped ceramic specimens under 10 N of load. The shear bond strengths (MPa) were measured using a universal testing machine at a cross head speed of 0.5 mm/min and 200 kgf of load. The data were submitted to statistical analysis (ANOVA and Tukey's test). Results: The air-particle abrasion group exhibited significantly higher shear bond strength when compared to drilled group (p < 0.05). Conclusions: Thermocycling decreased significantly the bond strengths for all groups tested.
Resumo:
This qualitative study was performed with 71 hypertensive patients, with the objectives to compare outpatient and home blood pressure monitoring (HBPM), to assess blood pressure control, and characterize white-coat hypertension. A nurse performed the outpatient blood pressure measurement. The home blood pressure monitoring was carried out over seven days. White-coat hypertension was quantified as a difference between the outpatient measurement and home blood pressure monitoring in the ranges from 1 to 5, 6 to 10 and > 10 mmHg. The outpatient blood pressure measurement was significantly higher (p<0.05) than the home blood pressure measurement. Pressure control corresponded to 9.9% in the outpatient measurement and 23.9% in the home blood pressure measurement. The white-coat effect > 10 mmHg was 57.7% for systolic and 32.4% for diastolic pressure, in the range from 6 to 10 mmHg. Home blood pressure measurement provided a better assessment of hypertensive patients' control.
Resumo:
Objective: Diastolic dysfunction (DD) is a frequent condition in hypertensive patients whose presence increases mortality and whose treatment remains unclear. The aim of this study was to investigate in a prospective, double-blinded, placebo-controlled randomized design the additive effect of simvastatin on DD in enalapril-treated hypertensive patients with average cholesterol levels. Methods: Hypertensive patients with DD and LDL-cholesterol <160 mg/dL underwent a run-in phase to achieve a systolic blood pressure (SBP) <135 mmHg and diastolic blood pressure (DBP) <85 mmHg with enalapril. Hydrochlorothiazide was added when need to achieve blood pressure control. Four weeks after reaching the optimum anti-hypertensive regimen patients were randomized to receive 80 mg simvastatin (n = 27) or placebo (n = 28) for a period of 20 weeks. Echocardiograms were performed before and after treatment with measurement of maximum left atrial volume (LAV), conventional and tissue Doppler velocities in early diastole (E, e') and late diastole (A, a'). Results: After 20 weeks, the simvastatin group presented reduction in SBP (-4 +/- 2 mmHg, p = 0.02), increase in E/A ratio (1.0 +/- 0.05 to 1.2 +/- 0.06, p = 0.03) and decrease of LAV indexed to body surface area (24.5 +/- 0.9 to 21.1 +/- 0.8 ml/m(2), p = 0.048), as compared with placebo arm. No change in systolic function and no correlation between the E/A ratio, LAV and changes in blood pressure or lipid profile were observed. Conclusions: The addition of simvastatin to enalapril in hypertensive patients with average cholesterol levels improves parameters of diastolic function independently of changes in blood pressure or cholesterol. (C) 2012 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The harm upon the central auditory pathways of workers exposed to occupational noise has been scarcely studied. Objective: To assess the central auditory pathways by testing the long latency auditory evoked potentials (P300) of individuals exposed to occupational noise and controls. Method: This prospective study enrolled 25 individuals with normal hearing thresholds. The subjects were divided into two groups: individuals exposed to occupational noise (13 subjects; case group) and individuals not exposed to occupational noise (12 subjects; control group). The P300 test was used with verbal and non-verbal stimuli. Results: No statistically significant differences were found between ears for any of the stimuli or between groups. The groups had no statistically significant difference for verbal or non-verbal stimuli. Case group subjects had longer latencies than controls. In qualitative analysis, a greater number of altered P300 test results for verbal and non-verbal stimuli was seen in the case group, despite the absence of statistically significant differences between case and control subjects. Conclusion: Individuals exposed to high sound pressure levels had longer P300 latencies in verbal and non-verbal stimuli when compared to controls.