25 resultados para System reliability index


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The six-minute-walk-test (6MWT) has been increasingly used in cystic fibrosis (CF) patients. However, few studies in children have correlated 6MWT with current parameters used to evaluate CF severity. Moreover, no study transformed the values of distance walked from meters into Z scores to avoid bias like age and gender, which are sources of 6MWT variability. Methods: A cross-sectional descriptive study was performed to analyze the correlations (Spearman) among forced expiratory volume in one second (FEV1), body mass index (BMI), chest radiography (CXR), chest tomography (CT), and 6MWT Z score (Z-6MWT). Clinically stable CF patients, aged 6-21 years, were included. Results: 34 patients, 14F/20M, mean age 12.1 +/- 4.0 years were studied. The mean Z-6MWT was -1.1 +/- 1.106. The following correlations versus Z-6MWT were found: FEV1 (r=0.59, r(2)=0.32, p=0.0002), BMI Z score (r=0.42, r(2)=0.17, p=0.013), CXR (r=0.34, r(2)=0.15, p=0.0472) and CT (r=-0.45, r(2)=0.23, p=0.0073). Conclusions: In conclusion there was a significant, but poor, correlation between the six minute walk test Z score and the cystic fibrosis severity markers currently in use. (C) 2011 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, the attainment of microsystems that integrate most of the stages involved in an analytical process has raised an enormous interest in several research fields. This approach provides experimental set-ups of increased robustness and reliability, which simplify their application to in-line and continuous biomedical and environmental monitoring. In this work, a novel, compact and autonomous microanalyzer aimed at multiwavelength colorimetric determinations is presented. It integrates the microfluidics (a three-dimensional mixer and a 25 mm length "Z-shape" optical flow-cell), a highly versatile multiwavelength optical detection system and the associated electronics for signal processing and drive, all in the same device. The flexibility provided by its design allows the microanalyzer to be operated either in single fixed mode to provide a dedicated photometer or in multiple wavelength mode to obtain discrete pseudospectra. To increase its reliability, automate its operation and allow it to work under unattended conditions, a multicommutation sub-system was developed and integrated with the experimental set-up. The device was initially evaluated in the absence of chemical reactions using four acidochromic dyes and later applied to determine some key environmental parameters such as phenol index, chromium(VI) and nitrite ions. Results were comparable with those obtained with commercial instrumentation and allowed to demonstrate the versatility of the proposed microanalyzer as an autonomous and portable device able to be applied to other analytical methodologies based on colorimetric determinations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Food intake and nutritional status modify the physiological responses of the immune system to illness and infection and regulate the development of chronic inflammatory processes, such as kidney disease. Adipose tissue secretes immune-related proteins called adipokines that have pleiotropic effects on both the immune and neuroendocrine systems, linking metabolism and immune physiology. Leptin, an adipose tissue-derived adipokine, displays a variety of immune and physiological functions, and participates in several immune responses. Here, we review the current literature on the role of leptin in kidney diseases, linking adipose tissue and the immune system with kidney-related disorders. The modulation of this adipose hormone may have a major impact on the treatment of several immune- and metabolic-related kidney diseases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Synchronous distributed generators are prone to operate islanded after contingencies, which is usually not allowed due to safety and power-quality issues. Thus, there are several anti-islanding techniques; however, most of them present technical limitations so that they are likely to fail in certain situations. Therefore, it is important to quantify and determine whether the scheme under study is adequate or not. In this context, this paper proposes an index to evaluate the effectiveness of anti-islanding frequency-based relays commonly used to protect synchronous distributed generators. The method is based on the calculation of a numerical index that indicates the time period that the system is unprotected against islanding considering the global period of analysis. Although this index can precisely be calculated based on several electromagnetic transient simulations, a practical method is also proposed to calculate it directly from simple analytical formulas or lookup tables. The results have shown that the proposed approach can assist distribution engineers to assess and set anti-islanding protection schemes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Because the mechanical behavior of the implant-abutment system is critical for the longevity of implant-supported reconstructions, this study evaluated the fatigue reliability of different implant-abutment systems used as single-unit crowns and their failure modes. Methods and Materials: Sixty-three Ti-6Al-4V implants were divided in 3 groups: Replace Select (RS); IC-IMP Osseotite; and Unitite were restored with their respective abutments. Anatomically correct central incisor metal crowns were cemented and subjected to separate single load to failure tests and step-stress accelerated life testing (n = 18). A master Weibull curve and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The load at failure mean values during step-stress accelerated life testing were 348.14 N for RS, 324.07 N for Osseotite, and 321.29 N for the Unitite systems. No differences in reliability levels were detected between systems, and only the RS system mechanical failures were shown to be accelerated by damage accumulation. Failure modes differed between systems. Conclusions: The 3 evaluated systems did not present significantly different reliability; however, failure modes were different. (Implant Dent 2012;21:67-71)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate the multisegmental static postural balance of active eutrophic and obese elderly women using a three-dimensional system under different sensory conditions. METHODS: A cross-sectional study was conducted on 31 elderly women (16 eutrophic and 15 obese) aged 65 to 75 years. The following anthropometric measurements were obtained: weight, height, waist and hip circumference, and handgrip strength. The physical activity level was evaluated using the International Physical Activity Questionnaire. Body composition was measured using the deuterium oxide dilution technique. The Polhemus (R) Patriot (three-dimensional) equipment was used to measure the parameters of postural balance along the anteroposterior and laterolateral axes. The data acquisition involved one trial of 60 s to test the limit of stability and four trials of 90 s each under the following conditions: (1) eyes open, stable surface; (2) eyes closed, stable surface; (3) eyes open, unstable surface; and (4) eyes closed, unstable surface. RESULTS: For the limit of stability, significant differences were observed in the maximum anteroposterior and laterolateral displacement (p<0.01) and in the parameter maximum anteroposterior displacement in the eyes closed stable surface condition (p<0.01) and maximum anteroposterior and laterolateral displacement in the eyes open unstable surface (p<0.01 and p = 0.03) and eyes closed unstable surface (p<0.01 and p<0.01) conditions. CONCLUSIONS: Obese elderly women exhibited a lower stability limit (lower sway area) compared with eutrophic women, leaving them more vulnerable to falls.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Public health strategies to reduce cardiovascular morbidity and mortality should focus on global cardiometabolic risk reduction. The efficacy of lifestyle changes to prevent type 2 diabetes have been demonstrated, but low-cost interventions to reduce cardiometabolic risk in Latin-America have been rarely reported. Our group developed 2 programs to promote health of high-risk individuals attending a primary care center in Brazil. This study compared the effects of two 9-month lifestyle interventions, one based on medical consultations (traditional) and another with 13 multi-professional group sessions in addition to the medical consultations (intensive) on cardiometabolic parameters. Adults were eligible if they had pre-diabetes (according to the American Diabetes Association) and/or metabolic syndrome (International Diabetes Federation criteria for Latin-America). Data were expressed as means and standard deviations or percentages and compared between groups or testing visits. A p-value < 0.05 was considered significant. Results: 180 individuals agreed to participate (35.0% men, mean age 54.7 ± 12.3 years, 86.1% overweight or obese). 83 were allocated to the traditional and 97 to the intensive program. Both interventions reduced body mass index, waist circumference and tumor necrosis factor-α. Only intensive program reduced 2-hour plasma glucose and blood pressure and increased adiponectin values, but HDL-cholesterol increased only in the traditional. Also, responses to programs were better in intensive compared to traditional program in terms of blood pressure and adiponectin improvements. No new case of diabetes in intensive but 3 cases and one myocardial infarction in traditional program were detected. Both programs induced metabolic improvement in the short-term, but if better results in the intensive are due to higher awareness about risk and self-motivation deserves further investigation. In conclusion, these low-cost interventions are able to minimize cardiometabolic risk factors involved in the progression to type 2 diabetes and/or cardiovascular disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In epidemiological surveys, a good reliability among the examiners regarding the caries detection method is essential. However, training and calibrating those examiners is an arduous task because it involves several patients who are examined many times. To facilitate this step, we aimed to propose a laboratory methodology to simulate the examinations performed to detect caries lesions using the International Caries Detection and Assessment System (ICDAS) in epidemiological surveys. Methods: A benchmark examiner conducted all training sessions. A total of 67 exfoliated primary teeth, varying from sound to extensive cavitated, were set in seven arch models to simulate complete mouths in primary dentition. Sixteen examiners (graduate students) evaluated all surfaces of the teeth under illumination using buccal mirrors and ball-ended probe in two occasions, using only coronal primary caries scores of the ICDAS. As reference standard, two different examiners assessed the proximal surfaces by direct visual inspection, classifying them in sound, with non-cavitated or with cavitated lesions. After, teeth were sectioned in the bucco-lingual direction, and the examiners assessed the sections in stereomicroscope, classifying the occlusal and smooth surfaces according to lesion depth. Inter-examiner reproducibility was evaluated using weighted kappa. Sensitivities and specificities were calculated at two thresholds: all lesions and advanced lesions (cavitated lesions in proximal surfaces and lesions reaching the dentine in occlusal and smooth surfaces). Conclusion: The methodology purposed for training and calibration of several examiners designated for epidemiological surveys of dental caries in preschool children using the ICDAS is feasible, permitting the assessment of reliability and accuracy of the examiners previously to the survey´s development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of new procedures for quickly obtaining accurate information on the physiological potential of seed lots is essential for developing quality control programs for the seed industry. In this study, the effectiveness of an automated system of seedling image analysis (Seed Vigor Imaging System - SVIS) in determining the physiological potential of sun hemp seeds and its relationship with electrical conductivity tests, were evaluated. SVIS evaluations were performed three and four days after sowing and data on the vigor index and the length and uniformity of seedling growth were collected. The electrical conductivity test was made on 50 seed replicates placed in containers with 75 mL of deionised water at 25 ºC and readings were taken after 1, 2, 4, 8 and 16 hours of imbibition. Electrical conductivity measurements at 4 or 8 hours and the use of the SVIS on 3-day old seedlings can effectively detect differences in vigor between different sun hemp seed lots.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In deterministic optimization, the uncertainties of the structural system (i.e. dimension, model, material, loads, etc) are not explicitly taken into account. Hence, resulting optimal solutions may lead to reduced reliability levels. The objective of reliability based design optimization (RBDO) is to optimize structures guaranteeing that a minimum level of reliability, chosen a priori by the designer, is maintained. Since reliability analysis using the First Order Reliability Method (FORM) is an optimization procedure itself, RBDO (in its classical version) is a double-loop strategy: the reliability analysis (inner loop) and the structural optimization (outer loop). The coupling of these two loops leads to very high computational costs. To reduce the computational burden of RBDO based on FORM, several authors propose decoupling the structural optimization and the reliability analysis. These procedures may be divided in two groups: (i) serial single loop methods and (ii) unilevel methods. The basic idea of serial single loop methods is to decouple the two loops and solve them sequentially, until some convergence criterion is achieved. On the other hand, uni-level methods employ different strategies to obtain a single loop of optimization to solve the RBDO problem. This paper presents a review of such RBDO strategies. A comparison of the performance (computational cost) of the main strategies is presented for several variants of two benchmark problems from the literature and for a structure modeled using the finite element method.