3 resultados para current controlled voltage-source inverter

em Repositório Institucional da Universidade Tecnológica Federal do Paraná (RIUT)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Brazil is the third largest producer and exporter of turkey meat, especially in Paraná state, with the largest production volume. In worldwide the animal welfare is a prerequisite for food quality of animal origin, especially in Europe. The Regulation of European Community No 1099/2009 provides requirements for poultry stunning that associate with animal welfare as a means to minimize the pain and suffering from the slaughter. Improper application of callousness should produce low-quality meat, and significant industry losses. This Research aimed to evaluate the impacts on the quality of meat from turkeys, applying electrical stunning parameters established in the Regulation No 1099/2009 of the Council of 24 September 2009. Was applied an outline with 8 tests set equidistantly to frequency, and set parameters for current and voltage, and a control test. Were conducted qualitative assessments of hematoms and bruises / fractures in carcasses, hematoms, blood splashed and bleeding in turkey breast, and quantitative pH, color (L *), water holding capacity and shear force in turkey breast. The individual assessments showed no significant difference (p>0,05). In multivariate cluster analysis was the formation of two distinct groups: group 1 - 50 Hz to 200 Hz (low frequency) and group 2 - 633 Hz to 1500 Hz (high frequency), which showed significant difference (p= 0,016). In principal component analysis multivariate, the group 1 tend to have a higher incidence of bruising, blood splashed, bleeding and water holding capacity in breast turkeys, and bruises / fractures and hematoms on carcasses. The Group 2 tends to have a lower incidence of these parameters, and higher pH values, shear force and color (L *). Positive correlation was obtained for the parameters pH and shear force (r= 0.7506, p=0.0198); bleeding and splashed blood (r= 0.8811, p= 0.0017), and negative correlation to color (L*) and splashed blood on breast (r= -0.7889; p= 0.0115); breast hematoms and shear force (r= -0.7844; p= 0.0123). It has been observed that at lower frequencies stunning tends to have higher incidence of defects in the carcasses and turkey breast. The use of high frequencies in stunning, create smaller quantity of trimming, and an increase in turkey breast volume produced, with a financial gain of approximately R$250,000.00 / year. Moreover, there is no need increase the workers to do the trimming tasks and, therefore, higher financial results for companies. Therefore, we recommend the use of high frequencies in the stunning of turkeys.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Distributed generation systems must fulfill standards specifications of current harmonics injected to the grid. In order to satisfy these grid requirements, passive filters are connected between inverter and grid. This work compares the characteristic response of the traditional inductive (L) filter with the inductive-capacitive-inductive (LCL) filter. It is shown that increasing the inductance L leads to a good ripple current suppression around the inverter switching frequency. The LCL filter provides better harmonic attenuation and reduces the filter size. The main drawback is the LCL filter impedance, which is characterized by a typical resonance peak, which must be damped to avoid instability. Passive or active techniques can be used to damp the LCL resonance. To address this issue, this dissertation presents a comparison of current control for PV grid-tied inverters with L filter and LCL filter and also discuss the use of active and passive damping for different regions of resonance frequency. From the mathematical models, a design methodology of the controllers was developed and the dynamic behavior of the system operating in closed loop was investigated. To validate the studies developed during this work, experimental results are presented using a three-phase 5kW experimental platform. The main components and their functions are discussed in this work. Experimental results are given to support the theoretical analysis and to illustrate the performance of grid-connected PV inverter system. It is shown that the resonant frequency of the system, and sampling frequency can be associated in order to calculate a critical frequency, below which is essential to perform the damping of the LCL filter. Also, the experimental results show that the active buffer per virtual resistor, although with a simple development, is effective to damp the resonance of the LCL filter and allow the system to operate stable within predetermined parameters.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presence of non-linear loads at a point in the distribution system may deform voltage waveform due to the consumption of non-sinusoidal currents. The use of active power filters allows significant reduction of the harmonic content in the supply current. However, the processing of digital control structures for these filters may require high performance hardware, particularly for reference currents calculation. This work describes the development of hardware structures with high processing capability for application in active power filters. In this sense, it considers an architecture that allows parallel processing using programmable logic devices. The developed structure uses a hybrid model using a DSP and an FPGA. The DSP is used for the acquisition of current and voltage signals, calculation of fundamental current related controllers and PWM generation. The FPGA is used for intensive signal processing, such as the harmonic compensators. In this way, from the experimental analysis, significant reductions of the processing time are achieved when compared to traditional approaches using only DSP. The experimental results validate the designed structure and these results are compared with other ones from architectures reported in the literature.