7 resultados para Satellite solar power stations.

em Repositório Científico da Universidade de Évora - Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Parabolic Trough (PT) is the most used concentrator in CSP (Concentrated Solar Power). However, this concentrator technology is facing a significant challenge to increase its overall efficiency and cost-effectiveness. Meanwhile, other low-cost solutions such as Fresnel concentrators are also being perceived as potentially attractive. In order to achieve the lower cost goal, new optical solutions can be considered, in parallel with improvements coming, for instance, through the use of new materials or manufacturing solutions. But conventional PTs can still be improved to yield, for instance, higher concentration values, a possible starting point for higher conversion efficiency. These new solutions, in turn, can also be useful for other technologies and applications (Fresnel Concentrators, Central Tower Receivers, etc.). However it is easier to develop and test these solutions in conjunction with parabolic primaries (continuum primary). And that is the topic of this paper: to present a new Compound Elliptical-type Concentrator for a parabolic primary with a tubular receiver. A comparison is made between this new concentrator and two other concentrators (a conventional PT concentrator and a XX SMS (Simultaneous Multiple Surface) concentrator), as well as a calculation of the total amount of collected energy (kW h) for a particular location, Faro (Portugal). The paper ends with a discussion of the results obtained, their impact and possible applications in the future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The variability in non-dispatchable power generation raises important challenges to the integration of renewable energy sources into the electricity power grid. This paper provides the coordinated trading of wind and photovoltaic energy to mitigate risks due to the wind and solar power variability, electricity prices, and financial penalties arising out the generation shortfall and surplus. The problem of wind-photovoltaic coordinated trading is formulated as a linear programming problem. The goal is to obtain the optimal bidding strategy that maximizes the total profit. The wind-photovoltaic coordinated operation is modeled and compared with the uncoordinated operation. A comparison of the models and relevant conclusions are drawn from an illustrative case study of the Iberian day-ahead electricity market.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The variability in non-dispatchable power generation raises important challenges to the integration of renewable energy sources into the electricity power grid. This paper provides the coordinated trading of wind and photovoltaic energy assisted by a cyber-physical system for supporting management decisions to mitigate risks due to the wind and solar power variability, electricity prices, and financial penalties arising out the generation shortfall and surplus. The problem of wind-photovoltaic coordinated trading is formulated as a stochastic linear programming problem. The goal is to obtain the optimal bidding strategy that maximizes the total profit. The wind-photovoltaic coordinated operation is modelled and compared with the uncoordinated operation. A comparison of the models and relevant conclusions are drawn from an illustrative case study of the Iberian day-ahead electricity market.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we analyze an optimal control problem for a system of two hydroelectric power stations in cascade with reversible turbines. The objective is to optimize the profit of power production while respecting the system’s restrictions. Some of these restrictions translate into state constraints and the cost function is nonconvex. This increases the complexity of the optimal control problem. The problem is solved numerically and two different approaches are adopted. These approaches focus on global optimization techniques (Chen-Burer algorithm) and on a projection estimation refinement method (PERmethod). PERmethod is used as a technique to reduce the dimension of the problem. Results and execution time of the two procedures are compared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method based on Spinning Enhanced Visible and Infrared Imager (SEVIRI) measured reflectance at 0.6 and 3.9 µm is used to retrieve the cloud optical thickness (COT) and cloud effective radius (re) over the Iberian Peninsula. A sensitivity analysis of simulated retrievals to the input parameters demonstrates that the cloud top height is an important factor in satellite retrievals of COT and re with uncertainties around 10% for small values of COT and re; for water clouds these uncertainties can be greater than 10% for small values of re. The uncertainties found related with geometries are around 3%. The COT and re are assessed using well-known satellite cloud products, showing that the method used characterize the cloud field with more than 80% (82%) of the absolute differences between COT (re) mean values of all clouds (water plus ice clouds) centred in the range from ±10 (±10 µm), with absolute bias lower than 2 (2 μm) for COT (re) and root mean square error values lower than 10 (8 μm) for COT (re). The cloud water path (CWP), derived from satellite retrievals, and the shortwave cloud radiative effect at the surface (CRESW) are related for high fractional sky covers (Fsc >0.8), showing that water clouds produce more negative CRESW than ice clouds. The COT retrieved was also related to the cloud modification factor, which exhibits reductions and enhancements of the surface SW radiation of the order of 80% and 30%, respectively, for COT values lower than 10. A selected case study shows, using a ground-based sky camera that some situations classified by the satellite with high Fsc values correspond to situations of broken clouds where the enhancements actually occur. For this case study, a closure between the liquid water path (LWP) obtained from the satellite retrievals and the same cloud quantity obtained from ground-based microwave measurements was performed showing a good agreement between both LWP data set values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Solar resource assessment is essential for the different phases of solar energy projects, such as preliminary design engineering, financing including due diligence and, later, insurance phases. An important aspect is the long term resource estimation. This kind of estimation can only be obtained through the statistical analysis of long-term data series of solar radiation measurements, preferably ground measurements. This paper is a first step in this direction, with an initial statistical analysis performed over the radiation data from a national measurement network, consisting of eighty-nine meteorological stations. These preliminary results are presented in figures that represent the annual average values of Global Horizontal Irradiation (GHI) and its Variability in the Portuguese continental territory. These results show that the South of Portugal is the most suitable area for the implementation of medium to large scale solar plants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A climate study of the incidence of downward surface global solar radiation (SSRD) in the Iberian Peninsula (IP) based primarily on ERA-40 reanalysis is presented. NCEP/NCAR reanalysis and ground-based records from several Portuguese and Spanish stations have been also considered. The results showthat reanalysis can capture a similar inter-annual variability as compared to ground-based observations, especially on a monthly basis, even though annual ERA-40 (NCEP/NCAR) values tend to underestimate (overestimate) the observations with a mean relative difference of around 20Wm–2 (40Wm–2). On the other hand, ground-based measurements in Portuguese stations during the period 1964–1989 show a tendency to decrease until the mid-1970s followed by an increase up to the end of the study period, in line with the dimming/brightening phenomenon reported in the literature. Nevertheless, there are different temporal behaviours as a greater increase since the 1970s is observed in the south and less industrialized regions. Similarly, the ERA-40 reanalysis shows a noticeable decrease until the early 1970s followed by a slight increase up to the end of the 1990s, suggesting a dimming/brightening transition around the early 1970s, earlier in the south and centre and later in the north of the IP. Although there are slight differences in the magnitude of the trends as well as the turning year of the dimming/brightening periods, the decadal changes of ERA-40 fairly agree with the ground-based observations in Portugal and Spain, in contrast to most of the literature for other regions of the world, and is used in the climatology of the SSRD in the study area. NCEP/NCAR reanalysis does not capture the decadal variations of SSRD in the IP. The results show that part of the decadal variability of the global radiation in the IP is related to changes in cloud cover (represented in ERA-40).