93 resultados para Tanning Devices
em Queensland University of Technology - ePrints Archive
Resumo:
The release of ultrafine particles (UFP) from laser printers and office equipment was analyzed using a particle counter (FMPS; Fast Mobility Particle Sizer) with a high time resolution, as well as the appropriate mathematical models. Measurements were carried out in a 1 m³ chamber, a 24 m³ chamber and an office. The time-dependent emission rates were calculated for these environments using a deconvolution model, after which the total amount of emitted particles was calculated. The total amounts of released particles were found to be independent of the environmental parameters and therefore, in principle, they were appropriate for the comparison of different printers. On the basis of the time-dependent emission rates, “initial burst” emitters and constant emitters could also be distinguished. In the case of an “initial burst” emitter, the comparison to other devices is generally affected by strong variations between individual measurements. When conducting exposure assessments for UFP in an office, the spatial distribution of the particles also had to be considered. In this work, the spatial distribution was predicted on a case by case basis, using CFD simulation.
Comparison of emission rate values for odour and odorous chemicals derived from two sampling devices
Resumo:
Field and laboratory measurements identified a complex relationship between odour emission rates provided by the US EPA dynamic emission chamber and the University of New South Wales wind tunnel. Using a range of model compounds in an aqueous odour source, we demonstrate that emission rates derived from the wind tunnel and flux chamber are a function of the solubility of the materials being emitted, the concentrations of the materials within the liquid; and the aerodynamic conditions within the device – either velocity in the wind tunnel, or flushing rate for the flux chamber. The ratio of wind tunnel to flux chamber odour emission rates (OU m-2 s) ranged from about 60:1 to 112:1. The emission rates of the model odorants varied from about 40:1 to over 600:1. These results may provide, for the first time, a basis for the development of a model allowing an odour emission rate derived from either device to be used for odour dispersion modelling.
Resumo:
This research explores gestures used in the context of activities in the workplace and in everyday life in order to understand requirements and devise concepts for the design of gestural information applicances. A collaborative method of video interaction analysis devised to suit design explorations, the Video Card Game, was used to capture and analyse how gesture is used in the context of six different domains: the dentist's office; PDA and mobile phone use; the experimental biologist's laboratory; a city ferry service; a video cassette player repair shop; and a factory flowmeter assembly station. Findings are presented in the form of gestural themes, derived from the tradition of qualitative analysis but bearing some similarity to Alexandrian patterns. Implications for the design of gestural devices are discussed.
Resumo:
Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to asses the forces needed to displace the tracker attachment devices in the bone simulators. Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices. The forces required to produce translation increased with the increasing diameter of the pins. These were 105N, 185N, and 225N for the unicortical fixations and 130N, 200N, 225N for the bicortical fixations for 3mm, 4mm and 5mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210N and 150N respectively. The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more that the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less that that can be produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.
Resumo:
This paper reports on a six month longitudinal study exploring people’s personal and social emotional experience with Portable Interactive Devices (PIDs). The study is concerned with the experience design approach and based on the theoretical framework of Activity Theory. The focus is on emotional experiences and how artefacts mediate and potentially enhance this experience. The outcomes of the study identified interesting aspects of PID interaction. Findings revealed people interact with PIDs emotionally both at a personal and a social level, supporting previous studies. Further, the social level impacts significantly on the emotional experience attained. If negative social experiences exceeded negative personal experiences the emotional experience was constant over six months. If negative personal experiences surpassed negative social experiences the emotional experience was varied over six months. The findings are discussed in regards to their significance to the field of design, their implication for future PID design and future research directions.
Resumo:
People in developed countries are living longer with the help of medical advances. Literature has shown that older people prefer to stay independent and live at home for as long as possible. Therefore, it is important to find out how to best accommodate and assist them in maintaining quality of life and independence as well as easing human resources. Researchers have claimed that assistive devices assist in older people’s independence, however, only a small number of studies regarding the efficiency of assistive devices have been undertaken of which several have stated that devices are not being used. The overall aim of this research was to identify whether the disuse and ineffectiveness of assistive devices are related to change in abilities or related to the design of the devices. The objective was to gather information from the elderly; to identify what assistive devices are being used or not used and to gain an understanding on their attitudes towards assistive devices. Research was conducted in two phases. The initial phase of the research was conducted with the distribution of questionnaires to people over the age of fifty that asked general questions and specific questions on type of devices being used. Phase One was followed on by Phase Two, where participants from Phase One who had come in contact with assistive devices were invited to participate in a semi-structured interview. Questions were put forth to the interviewee on their use of and attitudes towards assistive devices. Findings indicated that the reasons for the disuse in assistive devices were mostly design related; bulkiness, reliability, performance of the device, difficulty of use. The other main reason for disuse was socially related; elderly people preferred to undertake activities on their own and only use a device as a precaution or when absolutely necessary. They would prefer not having to rely on the devices. Living situation and difference in gender did not affect the preference for the use of assistive devices over personal assistance. The majority strongly supported the idea of remaining independent for as long as possible. In conclusion, this study proposes that through these findings, product designers will have a better understanding of the requirements of an elderly user. This will enable the designers to produce assistive devices that are more practical, personalised, reliable, easy to use and tie in with the older people’s environments. Additional research with different variables is recommended to further justify these findings.
Resumo:
This paper describes some new wireless sensor hardware developed for pastoral and environmental applications. From our early experiments with Mote hardware we were inspired to develop our devices with improved radio range, solar power capability, mechanical and electrical robustness, and with unique combinations of sensors. Here we describe the design and evolution of a small family of devices: radio/processor board, a soil moisture sensor interface, and a single board multi-sensor unit for animal tracking experiments.
Resumo:
Simulation study of a custom power park (CPP) is presented. It is assumed that the park contains unbalanced and nonlinear loads in addition to a sensitive load. Two different types of compensators are used separately to protect the sensitive load against unbalance and distortion caused by the other loads. It has been shown that a shunt compensator can regulate the voltage of the CPP bus, whereas the series compensator can only regulate the sensitive load terminal voltage. Additional issues such as the load transfer through a static transfer switch, detection of sag/fault etc. are also discussed. The concepts are validated through PSCAD/EMTDC simulation studies on a sample distribution system.
Resumo:
This paper reports on a six month longitudinal study exploring people’s personal and social emotional experience with health related portable interactive devices (PIDs). The focus is on emotions and how health PIDs mediate this experience in everyday contexts. The study reported here is an extension of a previous experiment conducted by the authors exploring media related PIDs [1]. The findings identified interesting aspects of health device interaction. Findings revealed people interact with health PIDs emotionally both at a personal and a social level. However, in contrast to media PIDs, participants reported significantly less social experiences than personal experiences. Nevertheless, the social level plays an important role such that negative social experiences had a significant influence on the perceived emotional experience over the course of six months. When no negative social experiences were reported the emotional experience over the course of six months became neutral. The findings are discussed in regards to their significance to the field of design, their implication for future health PID design and future research directions.