23 resultados para Photon pairs

em Queensland University of Technology - ePrints Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The consistently high failure rate in Queensland University of Technology’s introductory programming subject reflects a similar dilemma facing other universities worldwide. Experiments were conducted to quantify the effectiveness of collaborative learning on introductory level programming students over a number of semesters, replicating previous studies in this area. A selection of workshops in the introductory programming subject required students to problem-solve and program in pairs, mimicking the eXtreme Programming concept of pair programming. The failure rate for the subject fell from what had been an average of 30% since 2003 (with a high of 41% in 2006), to just 5% for those students who worked consistently in pairs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study employs a pairs trading investment strategy on daily commodity futures returns. The study reveals that pairs trading in similarly related commodity futures earns statistically significant excess returns with commensurate volatility. The excess returns from pairs trading in commodity futures are unrelated to conventional market risk factors and they are not associated with classic contrarian investing. The evidence of pairs trading reflect compensation to arbitrageurs for enforcing the law of one price in similarly related market efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Beam steering with high front-to-back ratio and high directivity on a small platform is proposed. Two closely spaced antenna pairs with eigenmode port decoupling are used as the basic radiating elements. Two orthogonal radiation patterns are obtained for each antenna pair. High front-to-back ratio and high directivity are achieved by combining the two orthogonal radiation patterns. With an infinite groundplane, a front-to-back ratio of 21 dB with a directivity of 9.8 dB can be achieved. Beam steering, at the expense of a slight decrease in directivity, is achieved by placing the two antenna pairs 0.5λ apart. The simulated half power beamwidth is 58°. A prototype was designed and the 2-D radiation patterns were measured. The prototype supports three directions of beam steering. The half power beamwidth was measured as 46°, 48°, and 50° for the three respective beam directions. The measured front-to-back ratio in azimuth plane is 8.5 dB, 8.0 dB and 7.6 dB, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A range of varying chromophore nitroxide free radicals and their nonradical methoxyamine analogues were synthesized and their linear photophysical properties examined. The presence of the proximate free radical masks the chromophore’s usual fluorescence emission, and these species are described as profluorescent. Two nitroxides incorporating anthracene and fluorescein chromophores (compounds 7 and 19, respectively) exhibited two-photon absorption (2PA) cross sections of approximately 400 G.M. when excited at wavelengths greater than 800 nm. Both of these profluorescent nitroxides demonstrated low cytotoxicity toward Chinese hamster ovary (CHO) cells. Imaging colocalization experiments with the commercially available CellROX Deep Red oxidative stress monitor demonstrated good cellular uptake of the nitroxide probes. Sensitivity of the nitroxide probes to H2O2-induced damage was also demonstrated by both one- and two-photon fluorescence microscopy. These profluorescent nitroxide probes are potentially powerful tools for imaging oxidative stress in biological systems, and they essentially “light up” in the presence of certain species generated from oxidative stress. The high ratio of the fluorescence quantum yield between the profluorescent nitroxide species and their nonradical adducts provides the sensitivity required for measuring a range of cellular redox environments. Furthermore, their reasonable 2PA cross sections provide for the option of using two-photon fluorescence microscopy, which circumvents commonly encountered disadvantages associated with one-photon imaging such as photobleaching and poor tissue penetration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article provides an overview on some of the key aspects that relate to the co-evolution of languages and its associated content in the Internet environment. A focus on such a co-evolution is pertinent as the evolution of languages in the Internet environment can be better understood if the development of its existing and emerging content, that is, the content in the respective language, is taken into consideration. By doing so, this article examines two related aspects: the governance of languages at critical sites of the Internet environment, including ICANN, Wikipedia and Google Translate. Following on from this examination, the second part outlines how the co-evolution of languages and associated content in the Internet environment extends policy-making related to linguistic pluralism. It is argued that policies which centre on language availability in the Internet environment must shift their focus to the dynamics of available content instead. The notion of language pairs as a new regime of intersection for both languages and content is discussed to introduce an extended understanding of the uses of linguistic pluralism in the Internet environment. The ultimate extrapolation of such an enhanced approach, it is argued, centres less on 6,000 languages but, instead, on 36 million language pairs. This article describes how such a powerful resource evolves in the Internet environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A5/1 is a shift register based stream cipher which uses a majority clocking rule to update its registers. It is designed to provide privacy for the GSM system. In this paper, we analyse the initialisation process of A5/1. We demonstrate a sliding property of the A5/1 cipher, where every valid internal state is also a legitimate loaded state and multiple key-IV pairs produce phase shifted keystream sequences. We describe a possible ciphertext only attack based on this property.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A5/1 is a shift register based stream cipher which provides privacy for the GSM system. In this paper, we analyse the loading of the secret key and IV during the initialisation process of A5/1. We demonstrate the existence of weak key-IV pairs in the A5/1 cipher due to this loading process; these weak key-IV pairs may generate one, two or three registers containing all-zero values, which may lead in turn to weak keystream sequences. In the case where two or three registers contain only zeros, we describe a distinguisher which leads to a complete decryption of the affected messages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the effects of handling and fixation processes on the two-photon fluorescence spectroscopy of endogenous fluorophors in mouse skeletal muscle. The skeletal muscle was handled in one of two ways: either sectioned without storage or sectioned following storage in a freezer. The two-photon fluorescence spectra measured for different storage or fixation periods show a differential among those samples that were stored in water or were fixed either in formalin or methanol. The spectroscopic results indicate that formalin was the least disruptive fixative, having only a weak effect on the two-photon fluorescence spectroscopy of muscle tissue, whereas methanol had a significant influence on one of the autofluorescence peaks. The two handling processes yielded similar spectral information, indicating no different effects between them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two-photon fluorescence spectroscopy has been performed on rat skeletal muscles to investigate the effect of fixation processes on the micro-environments of the endogenous fluorophors in rat skeletal muscles. The two-photon fluorescence spectra measured for different fixation periods show a differential among those samples that were fixed in water, formalin and methanol, respectively. The results imply that two-photon fluorescence spectroscopy can be a potential technique for identification of healthy and malignant biological tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the photoexcited state dynamics in a donor-acceptor copolymer, poly{3,6-dithiophene-2-yl-2,5-di(2-octyldodecyl)-pyrrolo[3,4-c]- pyrrole-1,4-dione-alt-naphthalene} (pDPP-TNT), by picosecond fluorescence and femtosecond transient absorption spectroscopies. Timeresolved fluorescence lifetime measurements of pDPP-TNT thin films reveal that the lifetime of the singlet excited state is 185 ± 5 ps and that singlet-singlet annihilation occurs at excitation photon densities above 6 × 1017 photons/cm3. From the results of singlet-singlet annihilation analysis, we estimate that the single-singlet annihilation rate constant is (6.0 ± 0.2) × 109cm3 s-1 and the singlet diffusion length is -7 nm. From the comparison of femtosecond transient absorption measurements and picosecond fluorescence measurements, it is found that the time profile of the photobleaching signal in the charge-transfer (CT) absorption band coincides with that of the fluorescence intensity and there is no indication of long-lived species, which clearly suggests that charged species, such as polaron pairs and triplet excitons, are not effectively photogenerated in the neat pDPP-TNT polymer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Influenza vaccination in pregnancy is recommended for all women in Australia, particularly those who will be in their second or third trimester during the influenza season. However, there has been no systematic monitoring of influenza vaccine uptake among pregnant women in Australia. Evidence is emerging of benefit to the infant with respect to preventing influenza infection in the first 6 months of life. The FluMum study aims to systematically monitor influenza vaccine uptake during pregnancy in Australia and determine the effectiveness of maternal vaccination in preventing laboratory-confirmed influenza in their offspring up to 6 months of age. METHODS AND ANALYSIS A prospective cohort study of 10 106 mother-infant pairs recruited between 38 weeks gestation and 55 days postdelivery in six Australian capital cities. Detailed maternal and infant information is collected at enrolment, including influenza illness and vaccination history with a follow-up data collection time point at infant age 6 months. The primary outcome is laboratory-confirmed influenza in the infant. Case ascertainment occurs through searches of Australian notifiable diseases data sets once the infant turns 6 months of age (with parental consent). The primary analysis involves calculating vaccine effectiveness against laboratory-confirmed influenza by comparing the incidence of influenza in infants of vaccinated mothers to the incidence in infants of unvaccinated mothers. Secondary analyses include annual and pooled estimates of the proportion of mothers vaccinated during pregnancy, the effectiveness of maternal vaccination in preventing hospitalisation for acute respiratory illness and modelling to assess the determinants of vaccination. ETHICS AND DISSEMINATION The study was approved by all institutional Human Research Ethics Committees responsible for participating sites. Study findings will be published in peer review journals and presented at national and international conferences. TRIAL REGISTRATION NUMBER The study is registered with the Australia and New Zealand Clinical Trials Registry (ANZCTR) number: 12612000175875.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines the effects of temporary tissue expanders (TTEs) on the dose distributions of photon beams in breast cancer radiotherapy treatments. EBT2 radiochromic film and ion chamber measurements were taken to quantify the attenuation and backscatter effects of the inhomogeneity. Results illustrate that the internal magnetic port present in a tissue expander causes a dose reduction of approximately 25% in photon tangent fields immediately downstream of the implant. It was also shown that the silicone elastomer shell of the tissue expander reduced the dose to the target volume by as much as 8%. This work demonstrates the importance for an accurately modelled high-density implant in the treatment planning system for post-mastectomy breast cancer patients.