75 resultados para Paper hand-held record PHR
em Queensland University of Technology - ePrints Archive
Resumo:
Background Historically, the paper hand-held record (PHR) has been used for sharing information between hospital clinicians, general practitioners and pregnant women in a maternity shared-care environment. Recently in alignment with a National e-health agenda, an electronic health record (EHR) was introduced at an Australian tertiary maternity service to replace the PHR for collection and transfer of data. The aim of this study was to examine and compare the completeness of clinical data collected in a PHR and an EHR. Methods We undertook a comparative cohort design study to determine differences in completeness between data collected from maternity records in two phases. Phase 1 data were collected from the PHR and Phase 2 data from the EHR. Records were compared for completeness of best practice variables collected The primary outcome was the presence of best practice variables and the secondary outcomes were the differences in individual variables between the records. Results Ninety-four percent of paper medical charts were available in Phase 1 and 100% of records from an obstetric database in Phase 2. No PHR or EHR had a complete dataset of best practice variables. The variables with significant improvement in completeness of data documented in the EHR, compared with the PHR, were urine culture, glucose tolerance test, nuchal screening, morphology scans, folic acid advice, tobacco smoking, illicit drug assessment and domestic violence assessment (p = 0.001). Additionally the documentation of immunisations (pertussis, hepatitis B, varicella, fluvax) were markedly improved in the EHR (p = 0.001). The variables of blood pressure, proteinuria, blood group, antibody, rubella and syphilis status, showed no significant differences in completeness of recording. Conclusion This is the first paper to report on the comparison of clinical data collected on a PHR and EHR in a maternity shared-care setting. The use of an EHR demonstrated significant improvements to the collection of best practice variables. Additionally, the data in an EHR were more available to relevant clinical staff with the appropriate log-in and more easily retrieved than from the PHR. This study contributes to an under-researched area of determining data quality collected in patient records.
Resumo:
The paper hand-held record (PHR) has been used extensively in general practice (GP) shared care management of pregnant women, and recently, the first Mater Shared Electronic Health Record (MSEHR) was introduced. The aim of this qualitative study was to examine women’s experiences using the records and the contribution of the records to integrate care. At the 36-week antenatal visit in a maternity tertiary centre clinic, women were identified as a user of either the PHR or the MSEHR and organised into Phase 1 and Phase 2 studies respectively. Fifteen women were interviewed in Phase 1 and 12 women in Phase 2. Semi-structured interviews were used for data collection, and analysed using qualitative content analysis. Four main themes were identified: (1) purpose of the record; (2) perceptions of the record; (3) content of the record, and; (4) sharing the record. Findings indicate that the PHR is a well-liked maternity tool. The findings also indicate there is under-usage of the MSEHR due to health-care providers failing to follow up and discuss the option of using the electronic health record option or if a woman has completed the log-in process. This paper adds to an already favourable body of knowledge about the use of the PHR. It is recommended that continued implementation of the MSEHR be undertaken to facilitate its use.
Resumo:
The antenatal paper hand-held record (PHR) has been used extensively in general practice (GP) shared-care management of pregnant women, but recently the antenatal electronic health record (EHR) was introduced. This study aimed to examine the experiences of women and health care providers who use the PHR and the EHR, and find out the relative role of these records in the integration of care. Purposive homogenous samples of women and health care providers were interviewed as users of the PHR in phase 1 and the EHR in phase 2 of the study. Qualitative data were collected via interview with women and GPs and focus groups held with hospital health care providers. Interviews were coded manually and analysed using qualitative content analysis. Fifteen women participated in phase 1 and 12 in phase 2. Seventeen GPs participated in phase 1 and 15 in phase 2. Five focus groups with hospital health care providers were conducted in each phase. Results were categorised into four themes: 1. Record purpose; 2. Perception of the record; 3. Content of the record, and; 4. Sharing information in the record. Both women and health care providers were familiar with the PHR, but identified that some information was missing or not utilised well, and reported underuse of the EHR. The study identified continued widespread use of the PHR and several issues concerning the use of the EHR. An improvement in the strategic implementation of the EHR is suggested as a mechanism to facilitate its wider adoption.
Resumo:
This present paper reviews the reliability and validity of visual analogue scales (VAS) in terms of (1) their ability to predict feeding behaviour, (2) their sensitivity to experimental manipulations, and (3) their reproducibility. VAS correlate with, but do not reliably predict, energy intake to the extent that they could be used as a proxy of energy intake. They do predict meal initiation in subjects eating their normal diets in their normal environment. Under laboratory conditions, subjectively rated motivation to eat using VAS is sensitive to experimental manipulations and has been found to be reproducible in relation to those experimental regimens. Other work has found them not to be reproducible in relation to repeated protocols. On balance, it would appear, in as much as it is possible to quantify, that VAS exhibit a good degree of within-subject reliability and validity in that they predict with reasonable certainty, meal initiation and amount eaten, and are sensitive to experimental manipulations. This reliability and validity appears more pronounced under the controlled (but more arti®cial) conditions of the laboratory where the signal : noise ratio in experiments appears to be elevated relative to real life. It appears that VAS are best used in within-subject, repeated-measures designs where the effect of different treatments can be compared under similar circumstances. They are best used in conjunction with other measures (e.g. feeding behaviour, changes in plasma metabolites) rather than as proxies for these variables. New hand-held electronic appetite rating systems (EARS) have been developed to increase reliability of data capture and decrease investigator workload. Recent studies have compared these with traditional pen and paper (P&P) VAS. The EARS have been found to be sensitive to experimental manipulations and reproducible relative to P&P. However, subjects appear to exhibit a signi®cantly more constrained use of the scale when using the EARS relative to the P&P. For this reason it is recommended that the two techniques are not used interchangeably
Resumo:
Background When large scale trials are investigating the effects of interventions on appetite, it is paramount to efficiently monitor large amounts of human data. The original hand-held Electronic Appetite Ratings System (EARS) was designed to facilitate the administering and data management of visual analogue scales (VAS) of subjective appetite sensations. The purpose of this study was to validate a novel hand-held method (EARS II (HP® iPAQ)) against the standard Pen and Paper (P&P) method and the previously validated EARS. Methods Twelve participants (5 male, 7 female, aged 18-40) were involved in a fully repeated measures design. Participants were randomly assigned in a crossover design, to either high fat (>48% fat) or low fat (<28% fat) meal days, one week apart and completed ratings using the three data capture methods ordered according to Latin Square. The first set of appetite sensations was completed in a fasted state, immediately before a fixed breakfast. Thereafter, appetite sensations were completed every thirty minutes for 4h. An ad libitum lunch was provided immediately before completing a final set of appetite sensations. Results Repeated measures ANOVAs were conducted for ratings of hunger, fullness and desire to eat. There were no significant differences between P&P compared with either EARS or EARS II (p > 0.05). Correlation coefficients between P&P and EARS II, controlling for age and gender, were performed on Area Under the Curve ratings. R2 for Hunger (0.89), Fullness (0.96) and Desire to Eat (0.95) were statistically significant (p < 0.05). Conclusions EARS II was sensitive to the impact of a meal and recovery of appetite during the postprandial period and is therefore an effective device for monitoring appetite sensations. This study provides evidence and support for further validation of the novel EARS II method for monitoring appetite sensations during large scale studies. The added versatility means that future uses of the system provides the potential to monitor a range of other behavioural and physiological measures often important in clinical and free living trials.
Resumo:
Thermal-infrared imagery is relatively robust to many of the failure conditions of visual and laser-based SLAM systems, such as fog, dust and smoke. The ability to use thermal-infrared video for localization is therefore highly appealing for many applications. However, operating in thermal-infrared is beyond the capacity of existing SLAM implementations. This paper presents the first known monocular SLAM system designed and tested for hand-held use in the thermal-infrared modality. The implementation includes a flexible feature detection layer able to achieve robust feature tracking in high-noise, low-texture thermal images. A novel approach for structure initialization is also presented. The system is robust to irregular motion and capable of handling the unique mechanical shutter interruptions common to thermal-infrared cameras. The evaluation demonstrates promising performance of the algorithm in several environments.
Resumo:
This study explored the psychological influences of hands-free and hand-held mobile phone use while driving. Participants were 796 Australian drivers aged 17 to 76 years who owned mobile phones. A cross-sectional survey assessed frequency of calling and text messaging while driving (overall, hands-free, hand-held) as well as drivers’ behavioural, normative, and control beliefs relating to mobile phone use while driving. Irrespective of handset type, 43% of drivers reported answering calls while driving on a daily basis, followed by making calls (36%), reading text messages (27%), and sending text messages (18%). In total, 63.9% of drivers did not own hands-free kits and, of the drivers that owned hand-free kits, 32% did not use it most or all of the time. Significant differences were found in the behavioural, normative, and control beliefs of frequent and infrequent users of both types of handset while driving. As expected, frequent users reported more advantages of, more approval from others for, and fewer barriers that would prevent them from, using either a hands-free or a hand-held mobile phone while driving than infrequent users. Campaigns to reduce mobile phone use while driving should attempt to minimise the perceived benefits of the behaviour and highlight the risks of this unsafe driving practice.
Resumo:
Hand-held mobile phone use while driving is illegal throughout Australia yet many drivers persist with this behaviour. This study aims to understand the internal, driver-related and external, situational-related factors influencing drivers’ willingness to use a hand-held mobile phone while driving. Sampling 160 university students, this study utilised the Theory of Planned Behaviour (TPB) to examine a range of belief-based constructs. Additionally, drivers’ personality traits of neuroticism and extroversion were measured with the Neuroticism Extroversion Openness-Five Factor Inventory (NEO-FFI). In relation to the external, situational-related factors, four different driving-related scenarios, which were intended to evoke differing levels of drivers’ reported stress, were devised for the study and manipulated drivers’ time urgency (low versus high) and passenger presence (alone versus with friends). In these scenarios, drivers’ willingness to use a mobile phone in general was measured. Hierarchical regression analyses across the four different driving scenarios found that, overall, the TPB components significantly accounted for drivers’ willingness to use a mobile phone above and beyond the demographic variables. Subjective norms, however, was only a significant predictor of drivers’ willingness in situations where the drivers were driving alone. Generally, neuroticism and extroversion did not significantly predict drivers’ willingness above and beyond the TPB and demographic variables. Overall, the findings broaden our understanding of the internal and external factors influencing drivers’ willingness to use a hand-held mobile phone while driving despite the illegality of this behaviour. The findings may have important practical implications in terms of better informing road safety campaigns targeting drivers’ mobile phone use which, in turn, may contribute to a reduction in the extent that mobile phone use contributes to road crashes.
Resumo:
Mobile devices are very popular among tertiary student populations. This study looks at student use of hand-held mobile devices within the context of a first year programming unit. This research sought for ways in which an educational app on these devices could be successfully integrated into such a class's learning.
Resumo:
In this paper we discuss how a network of sensors and robots can cooperate to solve important robotics problems such as localization and navigation. We use a robot to localize sensor nodes, and we then use these localized nodes to navigate robots and humans through the sensorized space. We explore these novel ideas with results from two large-scale sensor network and robot experiments involving 50 motes, two types of flying robot: an autonomous helicopter and a large indoor cable array robot, and a human-network interface. We present the distributed algorithms for localization, geographic routing, path definition and incremental navigation. We also describe how a human can be guided using a simple hand-held device that interfaces to this same environmental infrastructure.
Resumo:
A special transmit polarization signalling scheme is presented to alleviate the power reduction as a result of polarization mismatch from random antenna orientations. This is particularly useful for hand held mobile terminals typically equipped with only a single linearly polarized antenna, since the average signal power is desensitized against receiver orientations. Numerical simulations also show adequate robustness against incorrect channel estimations.
Resumo:
Recently I asked a first year student how he was coping with the transition from high school to university. The young fellow looked at me and said, “Man, everything is so different!” I smiled and said “like what?” with which he seriously replied, “Well for one thing, no one tells you that you have to wear a hat at lunch time.” I have to admit I was a little amused and surprised by this student’s response, as so often the focus, is placed on getting first year students to engage academically, when it is obvious at times, that even the mere transition in to university life and the culture itself, can be a hurdle. While teaching, within a large first year unit for over 10 years, it has become apparent that students want more connection with not only the peers that they study with, but also with the University as a whole. Dr Krause pointed out in her keynote paper, On Being Strategic about the First Year (2006), that this “sense of belonging is conducive to enhancing engagement, satisfaction with learning and commitment to study”. It has also become evident, that the way in which students want to be able to communicate has changed, with the advent of capabilities such as Instant Messaging via a network and Short Message Service SMS texting via their hand held mobile phones. To be able to chat and feel connected on social networking sites such as Bebo, Facebook and Twitter is not only a way of the future, it is here now and it is here to stay.
Resumo:
The progression of spinal deformity is traditionally monitored by spinal surgeons using the Cobb method on hardcopy radiographs with a protractor and pencil. The rotation of the spine and ribcage (rib hump) in scoliosis is measured with a simple hand-held inclinometer (Scoliometer). The iPhone and other smart phones have the capability to accurately sense inclination, and can therefore be used to measure Cobb angles and rib hump angulation. The purpose of this study was to quantify the performance of the iPhone compared to a standard protractor for measuring Cobb angles and the Scoliometer for measuring rib humps. The study concluded that the iPhone is a clinically equivalent measuring tool to the traditional protractor and Scoliometer
Resumo:
The progression of spinal deformity is traditionally monitored on hard copy radiographs using the Cobb method with a protractor and pencil. The rotation of the spine and ribcage (rib hump) in scoliosis is measured with a hand-held inclinometer/Scoliometer. The iPhone and other smart phones, can accurately sense inclination, and can therefore be used to measure Cobb angles and rib hump angulation. The purpose of this study was to quantify the performance of the iPhone compared to the standard protractor (Cobb angles) and the Scoliometer (rib hump).