8 resultados para Oximetry

em Queensland University of Technology - ePrints Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Isoindoline nitroxides are potentially useful probes for viable biological systems, exhibiting low cytotoxicity, moderate rates of biological reduction and favorable Electron Paramagnetic Resonance (EPR) characteristics. We have evaluated the anionic (5-carboxy-1,1,3,3-tetramethylisoindolin-2-yloxyl; CTMIO), cationic (5-(N,N,N-trimethylammonio)-1,1,3,3-tetramethylisoindolin-2-yloxyl iodide, QATMIO) and neutral (1,1,3,3-tetramethylisoindolin-2-yloxyl; TMIO) nitroxides and their isotopically labeled analogs ((2)H(12)- and/or (2)H(12)-(15)N-labeled) as potential EPR oximetry probes. An active ester analogue of CTMIO, designed to localize intracellularly, and the azaphenalene nitroxide 1,1,3,3-tetramethyl-2,3-dihydro-2-azaphenalen-2-yloxyl (TMAO) were also studied. While the EPR spectra of the unlabeled nitroxides exhibit high sensitivity to O(2) concentration, deuteration resulted in a loss of superhyperfine features and a subsequent reduction in O(2) sensitivity. Labeling the nitroxides with (15)N increased the signal intensity and this may be useful in decreasing the detection limits for in vivo measurements. The active ester nitroxide showed approximately 6% intracellular localization and low cytotoxicity. The EPR spectra of TMAO nitroxide indicated an increased rigidity in the nitroxide ring, due to dibenzo-annulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Nurses routinely use pulse oximetry (SpO2) monitoring equipment in acute care. Interpretation of the reading involves physical assessment and awareness of parameters including temperature, haemoglobin, and peripheral perfusion. However, there is little information on whether these clinical signs are routinely measured or used in pulse oximetry interpretation by nurses. Aim: The aim of this study was to review current practice of SpO2 measurement and the associated documentation of the physiological data that is required for accurate interpretation of the readings. The study reviewed the documentation practices relevant to SpO2 in five medical wards of a tertiary level metropolitan hospital. Method: A prospective casenote audit was conducted on random days over a three-month period. The audit tool had been validated in a previous study. Results: One hundred and seventy seven episodes of oxygen saturation monitoring were reviewed. Our study revealed a lack of parameters to validate the SpO2 readings. Only 10% of the casenotes reviewed had sufficient physiological data to meaningfully interpret the SpO2 reading and only 38% had an arterial blood gas as a comparator. Nursing notes rarely documented clinical interpretation of the results. Conclusion: The audits suggest that medical and nursing staff are not interpreting the pulse oximetry results in context and that the majority of the results were normal with no clinical indication for performing this observation. This reduces the usefulness of such readings and questions the appropriateness of performing “routine” SpO2 in this context.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The human-technology nexus is a strong focus of Information Systems (IS) research; however, very few studies have explored this phenomenon in anaesthesia. Anaesthesia has a long history of adoption of technological artifacts, ranging from early apparatus to present-day information systems such as electronic monitoring and pulse oximetry. This prevalence of technology in modern anaesthesia and the rich human-technology relationship provides a fertile empirical setting for IS research. This study employed a grounded theory approach that began with a broad initial guiding question and, through simultaneous data collection and analysis, uncovered a core category of technology appropriation. This emergent basic social process captures a central activity of anaesthestists and is supported by three major concepts: knowledge-directed medicine, complementary artifacts and culture of anaesthesia. The outcomes of this study are: (1) a substantive theory that integrates the aforementioned concepts and pertains to the research setting of anaesthesia and (2) a formal theory, which further develops the core category of appropriation from anaesthesia-specific to a broader, more general perspective. These outcomes fulfill the objective of a grounded theory study, being the formation of theory that describes and explains observed patterns in the empirical field. In generalizing the notion of appropriation, the formal theory is developed using the theories of Karl Marx. This Marxian model of technology appropriation is a three-tiered theoretical lens that examines appropriation behaviours at a highly abstract level, connecting the stages of natural, species and social being to the transition of a technology-as-artifact to a technology-in-use via the processes of perception, orientation and realization. The contributions of this research are two-fold: (1) the substantive model contributes to practice by providing a model that describes and explains the human-technology nexus in anaesthesia, and thereby offers potential predictive capabilities for designers and administrators to optimize future appropriations of new anaesthetic technological artifacts; and (2) the formal model contributes to research by drawing attention to the philosophical foundations of appropriation in the work of Marx, and subsequently expanding the current understanding of contemporary IS theories of adoption and appropriation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Preterm infants commence breastfeeding when health-care professionals deem them to be ready. However, the optimal timing for commencement of breastfeeding is unclear. Currently, there is little guidance for neonatal care providers to decide when to initiate breastfeeding among preterm infants. A mixed-methods study was conducted to develop and test the Preterm Sucking Readiness (PTSR) scale in four phases. The first phase involved a chart audit to explore the use of age as a criterion by investigating when preterm infants meet feeding milestones as well as other factors that may affect an infant’s readiness to engage in nutritive sucking behaviour. The second phase utilised focus groups to explore and define how neonatal care providers decide when to commence breastfeeding. To gain consensus on the criteria mentioned by the focus groups, a Delphi survey was conducted in phase 3, involving neonatal providers across Australia and New Zealand. Phase 4 of the study involved an observational study that was used to test the six-item PTSR. The age at which specific feeding milestones were reached was consistent with what has been previously described in the literature. The chart audit showed that the time taken to the first feeding attempt in the preterm infant population was affected by gestational age at birth, birth weight, and specific interventions. Staff also considered age along with other criteria when deciding when to initiate feeding. Consensus on nine criteria for inclusion into the six-item PTSR was achieved using the Delphi technique. Three items of PTSR showed significant differences between the preterm and fullterm infant groups. Only two items, feeding-readiness behaviour and low pulse oximetry during handling, explained the variance in breastfeeding behaviour. The inter-rater variability ranged between moderate and very good for the PTSR items. The results of this study indicate the importance of assessing behavioural cues as an indication of breastfeeding readiness in the preterm infant population, once an infant is deemed physiologically stable. Age continues to be a factor in some clinicians' decisions to commence breastfeeding. However, age alone cannot be used to decide if an infant is ready to engage in breastfeeding. Further research is needed to confirm these findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Endotracheal suctioning causes significant lung derecruitment. Closed suction (CS) minimizes lung volume loss during suction, and therefore, volumes are presumed to recover more quickly postsuctioning. Conflicting evidence exists regarding this. We examined the effects of open suction (OS) and CS on lung volume loss during suctioning, and recovery of end-expiratory lung volume (EELV) up to 30 minutes postsuction. Material and Methods Randomized crossover study examining 20 patients postcardiac surgery. CS and OS were performed in random order, 30 minutes apart. Lung impedance was measured during suction, and end-expiratory lung impedance was measured at baseline and postsuctioning using electrical impedance tomography. Oximetry, partial pressure of oxygen in the alveoli/fraction of inspired oxygen ratio and compliance were collected. Results Reductions in lung impedance during suctioning were less for CS than for OS (mean difference, − 905 impedance units; 95% confidence interval [CI], − 1234 to –587; P < .001). However, at all points postsuctioning, EELV recovered more slowly after CS than after OS. There were no statistically significant differences in the other respiratory parameters. Conclusions Closed suctioning minimized lung volume loss during suctioning but, counterintuitively, resulted in slower recovery of EELV postsuction compared with OS. Therefore, the use of CS cannot be assumed to be protective of lung volumes postsuctioning. Consideration should be given to restoring EELV after either suction method via a recruitment maneuver.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exercise-based cardiac rehabilitation (CR) is efficacious in reducing mortality and hospital admissions; however it remains inaccessible to large proportions of the patient population. Removal of attendance barriers for hospital or centre-based CR has seen the promotion of home-based CR. Delivery of safe and appropriately prescribed exercise in the home was first documented 25 years ago, with the utilisation of fixed land-line telecommunications to monitor ECG. The advent of miniature ECG sensors, in conjunction with smartphones, now enables CR to be delivered with greater flexibility with regard to location, time and format, while retaining the capacity for real-time patient monitoring. A range of new systems allow other signals including speed, location, pulse oximetry, and respiration to be monitored and these may have application in CR. There is compelling evidence that telemonitored-based CR is an effective alternative to traditional CR practice. The long-standing barrier of access to centre-based CR, combined with new delivery platforms, raises the question of when telemonitored-based CR could replace conventional approaches as the standard practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Many preterm neonates display difficulty establishing suck-feeding competence in the weeks following birth. Ineffective management of transitional feeding issues may cause patient complications, and can contribute to increased length of stay. Aims: Given that many neonatal nurseries appear to vary in their neonatal feeding management practices, the aim of this study was to investigate and document the routine level of support and intervention currently provided for preterm neonates with transitional feeding issues across the various level II (special care) nurseries (SCNs) in Queensland, Australia. Methods: A questionnaire was mailed to all Queensland SCNs in 2005 (n = 36). The questionnaire contained a series of closed-choice and short-answer questions designed to obtain information from each SCN regarding their current practices for managing transitional feeding issues in preterm neonates. Results were confirmed during a follow-up phone call. Results: Responses were obtained from 29 SCNs (80.6%). None of these nurseries reported having any formal, written policies regarding the management of transitional feeding issues in preterm neonates. Wide variations were reported in relation to the suck-feeding assessments and interventions used by staff within the various SCNs. Of the 29 nurseries, 4 (13.8%) reported using checklists or assessments to judge readiness for suck-feeds, and 5 (17.2%) reported using pulse oximetry to judge tolerance of suck-feeding attempts. Eighteen SCNs (62.1%) reported offering some form of active intervention to assist neonates with transitional feeding issues, with the most common intervention techniques reported being non-nutritive sucking during tube feeds, pre-feeding oral stimulation, and actively pacing suck-feeds. Twenty-two SCNs (75.4%) reported having access to a lactation consultant to assist mothers with breastfeeding issues. Conclusions: Differences were reported in the routine management of transitional feeding issues in preterm neonates across the various SCNs in Queensland. It is suggested that evidence based guidelines need to be developed, and that, in order to do this, further research studies are required to determine current best practice, as well as to answer remaining questions. © 2008 Elsevier Ireland Ltd. All rights reserved.