392 resultados para Output-boundary regulation

em Queensland University of Technology - ePrints Archive


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Corporate governance (CG) denotes the rules of business decision-making and directs the internal mechanism of companies to follow the output of the rules. It includes the customs, policies, laws and institutions as a set of processes that affects the way in which a corporation is directed, administered or controlled.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Regeneration and growth of the human endometrium after shedding of the functional layer during menstruation depends on an adequate angiogenic response. We analysed the mRNA expression levels of all known vascular endothelial growth factor (VEGF) ligands and receptors in human endometrium collected in the menstrual and proliferative phases of the menstrual cycle. In addition, we evaluated the expression of VEGF-A, VEGF-R2 and NRP-1 at the protein level. Two periods of elevated mRNA expression of ligands and receptors were observed, separated by a distinct drop at cycle days (CDs) 9 and 10. Immunohistochemical staining showed that VEGF and VEGF-R2 were expressed in epithelial, stromal and endothelial cells. NRP-1 was mainly confined to stroma and blood vessels; only in late-proliferative endometrium, epithelial staining was also observed. Except for endothelial VEGF-R2 expression in CDs 6-8, there were no significant differences in the expression of VEGF, VEGF-R2 or NRP-1 in any of the cell compartments. In contrast, VEGF release by cultured human endometrium explants decreased during the proliferative phase. This output was significantly reduced in menstrual and early-proliferative endometrium by estradiol (E2) treatment. Western blot analysis indicated that part of the VEGF-A was trapped in the extracellular matrix (ECM). Changes in VEGF ligands and receptors were associated with elevated expression of the hypoxia markers HIF1 alpha and CA-IX in the menstrual and early proliferative phases. HIF1 alpha was also detected in late-proliferative phase endometrium. Our findings indicate that VEGF-A exerts its actions mostly during the first half of the proliferative phase. Furthermore, VEGF-A production appears to be triggered by hypoxia in the menstrual phase and subsequently suppressed toy estrogen during the late proliferative phase.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The last two decades have witnessed a fragmentation of previously integrated systems of production and service delivery with the advent of boundary-less, networked and porous organisational forms. This trend has been associated with the growth of outsourcing and increased use of contingent workers. One consequence of these changes is the development of production/service delivery systems based on complex national and international networks of multi-tiered subcontracting increasingly labelled as supply chains. A growing body of research indicates that subcontracting and contingent work arrangements affect design and decision-making processes in ways that can seriously undermine occupational health and safety (OHS). Elaborate supply chains also present a regulatory challenge because legal responsibility for OHS is diffused amongst a wider array of parties, targeting key decision-makers is more difficult, and government agencies encounter greater logistical difficulties trying to safeguard contingent workers. In a number of industries these problems have prompted new forms of regulatory intervention, including mechanisms for sheeting legal responsibility to the top of supply chains, contractual tracking devices and increasing industry, union and community involvement in enforcement. After describing the problems just alluded to this paper examines recent efforts to regulate supply chains to safeguard OHS in the United Kingdom and Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a space fractional di®usion equation (SFDE) with non- homogeneous boundary conditions on a bounded domain is considered. A new matrix transfer technique (MTT) for solving the SFDE is proposed. The method is based on a matrix representation of the fractional-in-space operator and the novelty of this approach is that a standard discretisation of the operator leads to a system of linear ODEs with the matrix raised to the same fractional power. Analytic solutions of the SFDE are derived. Finally, some numerical results are given to demonstrate that the MTT is a computationally e±cient and accurate method for solving SFDE.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The accurate measurement of Cardiac output (CO) is vital in guiding the treatment of critically ill patients. Invasive or minimally invasive measurement of CO is not without inherent risks to the patient. Skilled Intensive Care Unit (ICU) nursing staff are in an ideal position to assess changes in CO following therapeutic measures. The USCOM (Ultrasonic Cardiac Output Monitor) device is a non-invasive CO monitor whose clinical utility and ease of use requires testing. Objectives To compare cardiac output measurement using a non-invasive ultrasonic device (USCOM) operated by a non-echocardiograhically trained ICU Registered Nurse (RN), with the conventional pulmonary artery catheter (PAC) using both thermodilution and Fick methods. Design Prospective observational study. Setting and participants Between April 2006 and March 2007, we evaluated 30 spontaneously breathing patients requiring PAC for assessment of heart failure and/or pulmonary hypertension at a tertiary level cardiothoracic hospital. Methods SCOM CO was compared with thermodilution measurements via PAC and CO estimated using a modified Fick equation. This catheter was inserted by a medical officer, and all USCOM measurements by a senior ICU nurse. Mean values, bias and precision, and mean percentage difference between measures were determined to compare methods. The Intra-Class Correlation statistic was also used to assess agreement. The USCOM time to measure was recorded to assess the learning curve for USCOM use performed by an ICU RN and a line of best fit demonstrated to describe the operator learning curve. Results In 24 of 30 (80%) patients studied, CO measures were obtained. In 6 of 30 (20%) patients, an adequate USCOM signal was not achieved. The mean difference (±standard deviation) between USCOM and PAC, USCOM and Fick, and Fick and PAC CO were small, −0.34 ± 0.52 L/min, −0.33 ± 0.90 L/min and −0.25 ± 0.63 L/min respectively across a range of outputs from 2.6 L/min to 7.2 L/min. The percent limits of agreement (LOA) for all measures were −34.6% to 17.8% for USCOM and PAC, −49.8% to 34.1% for USCOM and Fick and −36.4% to 23.7% for PAC and Fick. Signal acquisition time reduced on average by 0.6 min per measure to less than 10 min at the end of the study. Conclusions In 80% of our cohort, USCOM, PAC and Fick measures of CO all showed clinically acceptable agreement and the learning curve for operation of the non-invasive USCOM device by an ICU RN was found to be satisfactorily short. Further work is required in patients receiving positive pressure ventilation.