277 resultados para Occupant protection devices.

em Queensland University of Technology - ePrints Archive


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Correct use of child restraints reduces the risk of death and injury. Use of adult seat belts is better than being unrestrained but can result in injury to children who are too small. New Australian legislation extends the requirement for using child-specific restraints until children are 7 years old and thus requires more appropriate levels of protection for these children. As part of a larger study of injury prevention in Queensland, parents of children 0-9 years old were surveyed regarding their restraint practices before the introduction of the new legislation. The restraint status of 18% of the children would not be compliant with the new legislation, with the problem being more prevalent for 5-9 year olds (22%) than 0-4 year olds (16%). A high proportion of older children used an adult seat belt. Very few children aged 0-4 (1.3%) usually travelled in the front seat in contravention of the new requirement, but around 11% of this age group were reported as ever having done so. Usual travel in the front seat was higher among 5-9 year olds (8.5%), with more than half of the 5-9 year olds reported as ever having done so. Given the widespread use of adult seat belts by older children, there is a need to consider improving protection of children in the ‘gap’ between when the requirement for the child to use a booster ceases (effectively age 7) and when the adult belt is likely to actually fit the child (closer to age 9 or 10).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Road crashes contribute to a significant amount of child mortality and morbidity in Australia. In fact, passenger injuries contribute to the majority of child crash road trauma. A number of factors contribute to child injury and death in motor vehicles, including inappropriate seating position, inappropriate choice of restraint, and incorrect installation and use of child restraints. Prior to March 2010, child restraint legislation in Queensland only required children twelve months and younger to be seated in a properly adjusted and fastened child restraint. This legislation left older infants and young children potentially suboptimally protected. From March 2010, new legislation specified seating position and type of child restraint required, depending on the age of the child. This research was underpinned by the Health Belief Model (HBM), which explores health related behaviour, behaviour change, environmental factors influencing behaviour change (including legislative changes) and is flexible enough to be used in relation to parents' health practices for their children, rather than parent health directly. This thesis investigates the extent to which the changes to child restraint legislation have led parents in regional areas of Queensland to use appropriate restraint practices for their children and determines the extent to which the constructs of the HBM, parental perceptions, barriers and environmental factors contribute to the appropriateness of child seating and restraint use. Study One included three sets of observations taken in two regional cities of Queensland prior to the legislative amendment, during an educative period of six months, and after the enactment of the legislation. Each child's seating position and restraint type were recorded. Results showed that the proportion of children observed occupying the front seat decreased by 15.6 per cent with the announcement the legislation. There was no decrease in front seat use at the enactment of the legislation. The proportion of children observed using dedicated child restraints increased by 8.8 per cent with the announcement of the legislation when there was one child in the vehicle. Further, there was a 10.1 per cent increase in the proportion of children observed using a seat belt that fit with the announcement when there was one child in the vehicle and with the enactment of the legislation regardless of the number of children in the vehicle (21.8 per cent for one child, 39.7 per cent for two children and 40.2 per cent for three or more children). Study Two comprised initial intercept interviews, later followed up by telephone, with parents with children aged eight years and younger at the announcement and telephone interviews at the enactment of the legislation in one regional city in Queensland. Parents reported their child restraint practices, and opinions, knowledge and understanding of the requirements of the new legislation. Parent responses were analysed in terms of the constructs in the HBM. When asked which seating position their child 'usually' used, parents reported child front seat use was nil (0.0 per cent) and did not change with the enactment of the legislative amendment. However, when parents were asked whether they allowed children to use the front seat at some point within the six months prior to the interview, reported child front seat use was 7 (5.4 per cent) children at T2 and 10 (9.6 per cent) at T3. Reported use of age-appropriate child restraints did not increase with the enactment of the legislation (p = 0.77, ns). Parents reported restraint practices were classed as either appropriate or inappropriate. Parents who reported appropriate restraint practices were those whose children were sitting in optimal restraints and seating positions for their age according to the requirements of the legislation. Parents who reported inappropriate restraint practices were those who had one or more children who were suboptimally restrained or seated for their age according to the requirements of the legislation. Neither parents' perceptions about their susceptibility of being in a crash nor the likelihood of severity of child injury if involved in a crash yielded significant differences in the appropriateness of reported parent restraint practices over time with the enactment of the legislation. A trend in the data suggested parents perceived a benefit to using appropriate restraint practices was to avoid fines and demerit points. Over 75 per cent of parents who agreed that child restraints provide better protection for children than an adult seat belt reported appropriately seating and restraining their children (2 (1) = 8.093, p<.05). The self-efficacy measure regarding parents' confidence in installing a child restraint showed a significant association with appropriate parental restraint practices (2 (1) = 7.036, p<.05). Results suggested that some parents may have misinterpreted the announcement of the legislative amendment as the announcement of the enforcement of the legislation instead. Some parents who correctly reported details of the legislation did not report appropriate child restraint practices. This finding shows that parents' knowledge of the legislative amendment does not necessarily have an impact on their behaviour to appropriately seat and restrain children. The results of these studies have important implications for road safety and the prevention of road-related injury and death to children in Queensland. Firstly, parents reported feeling unsure of how to install restraints, which suggests that there may be children travelling in restraints that have not been installed correctly, putting them at risk. Interventions to alert and encourage parents to seek advice when unsure about the correct installation of child restraints could be considered. Secondly, some parents in this study although they were using the most appropriate restraint for their children, reported using a type that was not the most appropriate restraint for the child's age according to the legislation. This suggests that intervention may be effective in helping parents make a more accurate choice of the most appropriate type of restraint to use with children, especially as the child ages and child restraint requirements change. Further research could be conducted to ascertain the most effective methods of informing and motivating parents to use the most appropriate restraints and seating positions for their children, as these results show a concerning disparity between reported restraint practices and those that were observed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Norfolk Island is an Australian external territory in Oceania. The significant road safety reforms in Australia from the 1970s onward bypassed the island, and most road safety ‘silver bullets’ adopted in other Australian jurisdictions were not introduced. While legislative amendments in 2010 introduced mandatory seat belt wearing for vehicle occupants on Norfolk Island, other critical issues face the community including drink driving by residents and visitors, occupant protection for vehicle passengers, and the provision of a more protective road environment. The release of the first Norfolk Island road safety strategy 2014-2016 proposed, inter alia: • a lower BAC of 0.05 and the introduction of compulsory driver alcohol and drug testing by police; • targeted enforcement of occupant protection for vehicle passengers, particularly for passengers riding on vehicle tray backs; • education interventions to challenge values held by some members of the community that support unsafe road use; • ensuring that driver information, training and testing is adequate for all drivers; • identification and rectification of hazardous roadside infrastructure, particularly barrier protection at “high drop locations” within the road network; and • developing a specification for vehicle standards for vehicles imported into Norfolk Island. Norfolk Island is engaging in a process of integration with the Australian community, and wider issues relating to funding and resources have impacted on the implementation of the road safety strategy. The response to the strategy will be discussed, particularly in terms of current attempts to address drink driving and the provision of a safer road environment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This thesis has developed a new approach to trace virtual protection signals in Electrical substation networks. The main goal of the research was to analyse the contents of the virtual signals transferred, using third party software. In doing so, a comprehensive test was done on a distance protection relay, using non-conventional test equipment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Islanded operation, protection, reclosing and arc extinguishing are some of the challenging issues related to the connection of converter interfaced distributed generators (DGs) into a distribution network. The isolation of upstream faults in grid connected mode and fault detection in islanded mode using overcurrent devices are difficult. In the event of an arc fault, all DGs must be disconnected in order to extinguish the arc. Otherwise, they will continue to feed the fault, thus sustaining the arc. However, the system reliability can be increased by maximising the DG connectivity to the system: therefore, the system protection scheme must ensure that only the faulted segment is removed from the feeder. This is true even in the case of a radial feeder as the DG can be connected at various points along the feeder. In this paper, a new relay scheme is proposed which, along with a novel current control strategy for converter interfaced DGs, can isolate permanent and temporary arc faults. The proposed protection and control scheme can even coordinate with reclosers. The results are validated through PSCAD/EMTDC simulation and MATLAB calculations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the rapid increase in electrical energy demand, power generation in the form of distributed generation is becoming more important. However, the connections of distributed generators (DGs) to a distribution network or a microgrid can create several protection issues. The protection of these networks using protective devices based only on current is a challenging task due to the change in fault current levels and fault current direction. The isolation of a faulted segment from such networks will be difficult if converter interfaced DGs are connected as these DGs limit their output currents during the fault. Furthermore, if DG sources are intermittent, the current sensing protective relays are difficult to set since fault current changes with time depending on the availability of DG sources. The system restoration after a fault occurs is also a challenging protection issue in a converter interfaced DG connected distribution network or a microgrid. Usually, all the DGs will be disconnected immediately after a fault in the network. The safety of personnel and equipment of the distribution network, reclosing with DGs and arc extinction are the major reasons for these DG disconnections. In this thesis, an inverse time admittance (ITA) relay is proposed to protect a distribution network or a microgrid which has several converter interfaced DG connections. The ITA relay is capable of detecting faults and isolating a faulted segment from the network, allowing unfaulted segments to operate either in grid connected or islanded mode operations. The relay does not make the tripping decision based on only the fault current. It also uses the voltage at the relay location. Therefore, the ITA relay can be used effectively in a DG connected network in which fault current level is low or fault current level changes with time. Different case studies are considered to evaluate the performance of the ITA relays in comparison to some of the existing protection schemes. The relay performance is evaluated in different types of distribution networks: radial, the IEEE 34 node test feeder and a mesh network. The results are validated through PSCAD simulations and MATLAB calculations. Several experimental tests are carried out to validate the numerical results in a laboratory test feeder by implementing the ITA relay in LabVIEW. Furthermore, a novel control strategy based on fold back current control is proposed for a converter interfaced DG to overcome the problems associated with the system restoration. The control strategy enables the self extinction of arc if the fault is a temporary arc fault. This also helps in self system restoration if DG capacity is sufficient to supply the load. The coordination with reclosers without disconnecting the DGs from the network is discussed. This results in increased reliability in the network by reduction of customer outages.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our daily lives become more and more dependent upon smartphones due to their increased capabilities. Smartphones are used in various ways from payment systems to assisting the lives of elderly or disabled people. Security threats for these devices become increasingly dangerous since there is still a lack of proper security tools for protection. Android emerges as an open smartphone platform which allows modification even on operating system level. Therefore, third-party developers have the opportunity to develop kernel-based low-level security tools which is not normal for smartphone platforms. Android quickly gained its popularity among smartphone developers and even beyond since it bases on Java on top of "open" Linux in comparison to former proprietary platforms which have very restrictive SDKs and corresponding APIs. Symbian OS for example, holding the greatest market share among all smartphone OSs, was closing critical APIs to common developers and introduced application certification. This was done since this OS was the main target for smartphone malwares in the past. In fact, more than 290 malwares designed for Symbian OS appeared from July 2004 to July 2008. Android, in turn, promises to be completely open source. Together with the Linux-based smartphone OS OpenMoko, open smartphone platforms may attract malware writers for creating malicious applications endangering the critical smartphone applications and owners� privacy. In this work, we present our current results in analyzing the security of Android smartphones with a focus on its Linux side. Our results are not limited to Android, they are also applicable to Linux-based smartphones such as OpenMoko Neo FreeRunner. Our contribution in this work is three-fold. First, we analyze android framework and the Linux-kernel to check security functionalities. We survey wellaccepted security mechanisms and tools which can increase device security. We provide descriptions on how to adopt these security tools on Android kernel, and provide their overhead analysis in terms of resource usage. As open smartphones are released and may increase their market share similar to Symbian, they may attract attention of malware writers. Therefore, our second contribution focuses on malware detection techniques at the kernel level. We test applicability of existing signature and intrusion detection methods in Android environment. We focus on monitoring events on the kernel; that is, identifying critical kernel, log file, file system and network activity events, and devising efficient mechanisms to monitor them in a resource limited environment. Our third contribution involves initial results of our malware detection mechanism basing on static function call analysis. We identified approximately 105 Executable and Linking Format (ELF) executables installed to the Linux side of Android. We perform a statistical analysis on the function calls used by these applications. The results of the analysis can be compared to newly installed applications for detecting significant differences. Additionally, certain function calls indicate malicious activity. Therefore, we present a simple decision tree for deciding the suspiciousness of the corresponding application. Our results present a first step towards detecting malicious applications on Android-based devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The IEC 61850 family of standards for substation communication systems were released in the early 2000s, and include IEC 61850-8-1 and IEC 61850-9-2 that enable Ethernet to be used for process-level connections between transmission substation switchyards and control rooms. This paper presents an investigation of process bus protection performance, as the in-service behavior of multi-function process buses is largely unknown. An experimental approach was adopted that used a Real Time Digital Simulator and 'live' substation automation devices. The effect of sampling synchronization error and network traffic on transformer differential protection performance was assessed and compared to conventional hard-wired connections. Ethernet was used for all sampled value measurements, circuit breaker tripping, transformer tap-changer position reports and Precision Time Protocol synchronization of sampled value merging unit sampling. Test results showed that the protection relay under investigation operated correctly with process bus network traffic approaching 100% capacity. The protection system was not adversely affected by synchronizing errors significantly larger than the standards permit, suggesting these requirements may be overly conservative. This 'closed loop' approach, using substation automation hardware, validated the operation of protection relays under extreme conditions. Digital connections using a single shared Ethernet network outperformed conventional hard-wired solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conflicts in Iraq and Afghanistan have been epitomized by the insurgents’ use of the improvised explosive device against vehicle-borne security forces. These weapons, capable of causing multiple severely injured casualties in a single incident, pose the most prevalent single threat to Coalition troops operating in the region. Improvements in personal protection and medical care have resulted in increasing numbers of casualties surviving with complex lower limb injuries, often leading to long-term disability. Thus, there exists an urgent requirement to investigate and mitigate against the mechanism of extremity injury caused by these devices. This will necessitate an ontological approach, linking molecular, cellular and tissue interaction to physiological dysfunction. This can only be achieved via a collaborative approach between clinicians, natural scientists and engineers, combining physical and numerical modelling tools with clinical data from the battlefield. In this article, we compile existing knowledge on the effects of explosions on skeletal injury, review and critique relevant experimental and computational research related to lower limb injury and damage and propose research foci required to drive the development of future mitigation technologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blast mats that can be retrofitted to the floor of military vehicles are considered to reduce the risk of injury from under‐vehicle explosions. Anthropometric test devices (ATDs) are validated for use only in the seated position. The aim of this study was to use a traumatic injury simulator fitted with 3 different blast mats in order to assess the ability of 2 ATD designs to evaluate the protective capacity of the mats in 2 occupant postures under 2 severities. Tests were performed for each combination of mat design, ATD, severity and posture using an antivehicle under‐belly injury simulator. The differences between mitigation systems were larger under the H‐III compared to the MiL‐Lx. There was little difference in how the 2 ATDs and how posture ranked the mitigation systems. Results from this study suggest that conclusions obtained by testing in the seated position can be extrapolated to the standing. However, the different percentage reductions observed in the 2 ATDs suggests different levels of protection. It is therefore unclear which ATD should be used to assess such mitigation systems. A correlation between cadavers and ATDs on the protection offered by blast mats is required in order to elucidate this issue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The lower limb of military vehicle occupants has been the most injured body part due to undervehicle explosions in recent conflicts. Understanding the injury mechanism and causality of injury severity could aid in developing better protection. Therefore, we tested 4 different occupant postures (seated, brace, standing, standing with knee locked in hyper‐extension) in a simulated under‐vehicle explosion (solid blast) using our traumatic injury simulator in the laboratory; we hypothesised that occupant posture would affect injury severity. No skeletal injury was observed in the specimens in seated and braced postures. Severe, impairing injuries were observed in the foot of standing and hyper‐extended specimens. These results demonstrate that a vehicle occupant whose posture at the time of the attack incorporates knee flexion is more likely to be protected against severe skeletal injury to the lower leg.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

4-Hexylbithienopyridine has been prepared as a novel electron-accepting monomer for conjugated polymers. To test its electronic properties, alternating copolymers with fluorene and indenofluorene polymers have been prepared. The copolymers displayed reduction potentials about 0.5 V lower than for the corresponding fluorene and indenofluorene homopolymers, indicating much improved electron-accepting properties. Analysis of the microscopic morphology of thin films of the copolymers by AFM shows that they lack the extensive supramolecular order seen with the homopolymers, which is attributed to the bithienopyridine units disrupting the π-stacking. LEDs using these polymers as the emitting layer produce blue-green emission with low turn-on voltages with aluminum electrodes confirming their improved electron affinity. The indenofluorene copolymer displayed an irreversible red shift in emission at high voltages, which is attributed to oxidation of the indenofluorene units. This red shift occurred at higher potentials than for indenofluorene homopolymers in LEDs, suggesting that the heterocyclic moieties offer some protection against electrically promoted oxidation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, integration of small-scale electricity generators, known as Distributed Generation (DG), into distribution networks has become increasingly popular. This tendency together with the falling price of DG units has a great potential in giving the DG a better chance to participate in voltage regulation process, in parallel with other regulating devices already available in the distribution systems. The voltage control issue turns out to be a very challenging problem for distribution engineers, since existing control coordination schemes need to be reconsidered to take into account the DG operation. In this paper, a control coordination approach is proposed, which is able to utilize the ability of the DG as a voltage regulator, and at the same time minimize the interaction of DG with another DG or other active devices, such as On-load Tap Changing Transformer (OLTC). The proposed technique has been developed based on the concepts of protection principles (magnitude grading and time grading) for response coordination of DG and other regulating devices and uses Advanced Line Drop Compensators (ALDCs) for implementation. A distribution feeder with tap changing transformer and DG units has been extracted from a practical system to test the proposed control technique. The results show that the proposed method provides an effective solution for coordination of DG with another DG or voltage regulating devices and the integration of protection principles has considerably reduced the control interaction to achieve the desired voltage correction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Crash cushions are devices deployed on the road network in order to shield fixed roadside hazards and the non-crashworthy ends of road safety barriers. However crash cushions vary in terms of configuration and operation, meaning that different devices may also vary in terms of ability to mitigate occupant risk. In this study, data derived from crash testing of eleven redirective crash cushions is used as the base input to a numerical procedure for calculation of occupant risk indicators Occupant Impact Velocity (OIV), Occupant Ridedown Acceleration (ORA) and longitudinal Acceleration Severity Index (ASI) for a range of simulated impacting vehicles (mass 800 kg to 2,500 kg) impacting each crash cushion at a range of impact speeds (18 m/s to 32 m/s). The results may be interpreted as demonstrating firstly that enhanced knowledge of the performance of a device over a range of impact conditions, i.e., beyond the crash testing, may assist in determining the crash cushion most suited to a particular application; secondly that a more appropriate conformance test for occupant risk would be a frontal impact by a small (light) vehicle travelling parallel to and aligned with the centreline of the crash cushion; and thirdly that current documented numerical procedures for calculating occupant risk indicators may require review.