109 resultados para Gauge groups

em Queensland University of Technology - ePrints Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter is a condensation of a guide written by the chapter authors for both university teachers and students (Fowler et al., 2006). All page references given in this chapter are to this guide, unless otherwise stated. University students often work in groups. It may be a formal group (i.e. one that has been formed for a group presentation, writing a report, or completing a project) or an informal group (i.e. some students have decided to form a study group or undertake research together). Whether formal or informal, this chapter aims to make working in groups easier for you. Health care professionals also often work in groups. Yes, working in groups will extend well beyond your time at university. In fact, the skills and abilities to work effectively in groups are some of the most sought-after attributes in health care professionals. It seems obvious, then, that taking the opportunity to develop and enhance your skills and abilities for working in groups is a wise choice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined differences in response latencies obtained during a validated video-based hazard perception driving test between three healthy, community-dwelling groups: 22 mid-aged (35-55 years), 34 young-old (65-74 years), and 23 old-old (75-84 years) current drivers, matched for gender, education level, and vocabulary. We found no significant difference in performance between mid-aged and young-old groups, but the old-old group was significantly slower than the other two groups. The differences between the old-old group and the other groups combined were independently mediated by useful field of view (UFOV), contrast sensitivity, and simple reaction time measures. Given that hazard perception latency has been linked with increased crash risk, these results are consistent with the idea that increased crash risk in older adults could be a function of poorer hazard perception, though this decline does not appear to manifest until age 75+ in healthy drivers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent times, light gauge cold-formed steel sections have been used extensively as primary load bearing structural members in many applications in the building industry. Fire safety design of structures using such sections has therefore become more important. Deterioration of mechanical properties of yield stress and elasticity modulus is considered the most important factor affecting the performance of steel structures in fires. Hence there is a need to fully understand the mechanical properties of light gauge cold-formed steels at elevated temperatures. A research project based on experimental studies was therefore undertaken to investigate the deterioration of mechanical properties of light gauge cold-formed steels. Tensile coupon tests were undertaken to determine the mechanical properties of these steels made of both low and high strength steels and thicknesses of 0.60, 0.80 and 0.95 mm at temperatures ranging from 20 to 800ºC. Test results showed that the currently available reduction factors are unsafe to use in the fire safety design of cold-formed steel structures. Therefore new predictive equations were developed for the mechanical properties of yield strength and elasticity modulus at elevated temperatures. This paper presents the details of the experimental study, and the results including the developed equations. It also includes details of a stress-strain model for light gauge cold-formed steels at elevated temperatures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Developing the social identity theory of leadership (e.g., [Hogg, M. A. (2001). A social identity theory of leadership. Personality and Social Psychology Review, 5, 184–200]), an experiment (N=257) tested the hypothesis that as group members identify more strongly with their group (salience) their evaluations of leadership effectiveness become more strongly influenced by the extent to which their demographic stereotype-based impressions of their leader match the norm of the group (prototypicality). Participants, with more or less traditional gender attitudes (orientation), were members, under high or low group salience conditions (salience), of non-interactive laboratory groups that had “instrumental” or “expressive” group norms (norm), and a male or female leader (leader gender). As predicted, these four variables interacted significantly to affect perceptions of leadership effectiveness. Reconfiguration of the eight conditions formed by orientation, norm and leader gender produced a single prototypicality variable. Irrespective of participant gender, prototypical leaders were considered more effective in high then low salience groups, and in high salience groups prototypical leaders were more effective than less prototypical leaders. Alternative explanations based on status characteristics and role incongruity theory do not account well for the findings. Implications of these results for the glass ceiling effect and for a wider social identity analysis of the impact of demographic group membership on leadership in small groups are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire design is an essential element of the overall design procedure of structural steel members and systems. Conventionally the fire rating of load-bearing stud wall systems made of light gauge steel frames (LSF) is based on approximate prescriptive methods developed on the basis of limited fire tests. This design is limited to standard wall configurations used by the industry. Increased fire rating is provided simply by adding more plasterboards to the stud walls. This is not an acceptable situation as it not only inhibits innovation and structural and cost efficiencies but also casts doubt over the fire safety of these light gauge steel stud wall systems. Hence a detailed fire research study into the performance and effectiveness of a recently developed innovative composite panel wall system was undertaken at Queensland University of Technology using both full scale fire tests and numerical studies. Experimental results of LSF walls using the new composite panels under axial compression load have shown the improvement in fire performance and fire resistance rating. Numerical analyses are currently being undertaken using the finite element program ABAQUS. Measured temperature profiles of the studs are used in the numerical models and the results are used to calibrate against full scale test results. The validated model will be used in a detailed parametric study with an aim to develop suitable design rules within the current cold-formed steel structures and fire design standards. This paper will present the results of experimental and numerical investigations into the structural and fire behaviour of light gauge steel stud walls protected by the new composite panel. It will demonstrate the improvements provided by the new composite panel system in comparison to traditional wall systems.