173 resultados para Four-leg

em Queensland University of Technology - ePrints Archive


Relevância:

40.00% 40.00%

Publicador:

Resumo:

There are an increasing number of compression systems available for treatment of venous leg ulcers and limited evidence on the relative effectiveness of these systems. The purpose of this study was to conduct a randomised controlled trial to compare the effectiveness of a 4-layer compression bandage system with Class 3 compression hosiery on healing and quality of life in patients with venous leg ulcers. Data were collected from 103 participants on demographics, health, ulcer status, treatments, pain, depression and quality of life for 24 weeks. After 24 weeks, 86% of the 4-layer bandage group and 77% of the hosiery group were healed (p=0.24). Median time to healing for the bandage group was 10 weeks, in comparison to 14 weeks for the hosiery group (p=0.018). Cox proportional hazards regression found participants in the 4-layer system were 2.1 times (95% CI 1.2–3.5) more likely to heal than those in hosiery, while longer ulcer duration, larger ulcer area and higher depression scores significantly delayed healing. No differences between groups were found in quality of life or pain measures. Findings indicate these systems were equally effective in healing patients by 24 weeks, however a 4-layer system may produce a more rapid response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A high voltage pulsed power supply is proposed in this paper based on oscillation between an inductor and a capacitor in an LC circuit. A two-leg resonant circuit, supplied through an inverter with an alternative voltage waveform, can generate output voltage up to four times an input voltage magnitude. Bipolar and unipolar modulations are used in a single phase inverter to analyse their effects on the proposed resonant converter. Simulations have been carried out to evaluate the proposed topology and control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Pre-participation screening is commonly used to measure and assess potential intrinsic injury risk. The single leg squat is one such clinical screening measure used to assess lumbopelvic stability and associated intrinsic injury risk. With the addition of a decline board, the single leg decline squat (SLDS) has been shown to reduce ankle dorsiflexion restrictions and allowed greater sagittal plane movement of the hip and knee. On this basis, the SLDS has been employed in the Cricket Australia physiotherapy screening protocols as a measure of lumbopelvic control in the place of the more traditional single leg flat squat (SLFS). Previous research has failed to demonstrate which squatting technique allows for a more comprehensive assessment of lumbopelvic stability. Tenuous links are drawn between kinematics and hip strength measures within the literature for the SLS. Formal evaluation of subjective screening methods has also been suggested within the literature. Purpose: This study had several focal points namely 1) to compare the kinematic differences between the two single leg squatting conditions, primarily the five key kinematic variables fundamental to subjectively assess lumbopelvic stability; 2) determine the effect of ankle dorsiflexion range of motion has on squat kinematics in the two squat techniques; 3) examine the association between key kinematics and subjective physiotherapists’ assessment; and finally 4) explore the association between key kinematics and hip strength. Methods: Nineteen (n=19) subjects performed five SLDS and five SLFS on each leg while being filmed by an 8 camera motion analysis system. Four hip strength measures (internal/external rotation and abd/adduction) and ankle dorsiflexion range of motion were measured using a hand held dynamometer and a goniometer respectively on 16 of these subjects. The same 16 participants were subjectively assessed by an experienced physiotherapist for lumbopelvic stability. Paired samples t-tests were performed on the five predetermined kinematic variables to assess the differences between squat conditions. A Bonferroni correction for multiple comparisons was used which adjusted the significance value to p = 0.005 for the paired t-tests. Linear regressions were used to assess the relationship between kinematics, ankle range of motion and hip strength measures. Bivariate correlations between hip strength measures and kinematics and pelvic obliquity were employed to investigate any possible relationships. Results: 1) Significant kinematic differences between squats were observed in dominant (D) and non-dominant (ND) end of range hip external rotation (ND p = <0.001; D p = 0.004) and hip adduction kinematics (ND p = <0.001; D p = <0.001). With the mean angle, only the non-dominant leg observed significant differences in hip adduction (p = 0.001) and hip external rotation (p = <0.001); 2) Significant linear relationships were observed between clinical measures of ankle dorsiflexion and sagittal plane kinematic namely SLFS dominant ankle (p = 0.006; R2 = .429), SLFS non-dominant knee (p = 0.015; R2 = .352) and SLFS non-dominant ankle (p = 0.027; R2 = .305) kinematics. Only the dominant ankle (p = 0.020; R2 = .331) was found to have a relationship with the decline squat. 3) Strength measures had tenuous associations with the subjective assessments of lumbopelvic stability with no significant relationships being observed. 4) For the non-dominant leg, external rotation strength and abduction strength were found to be significantly correlated with hip rotation kinematics (Newtons r = 0.458 p = 0.049; Normalised for bodyweight: r = 0.469; p = 0.043) and pelvic obliquity (normalised for bodyweight: r = 0.498 p = 0.030) respectively for the SLFS only. No significant relationships were observed in the dominant leg for either squat condition. Some elements of the hip strength screening protocols had linear relationships with kinematics of the lower limb, particularly the sagittal plane movements of the knee and ankle. Strength measures had tenuous associations with the subjective assessments of lumbopelvic stability with no significant relationships being observed; Discussion: The key finding of this study illustrated that kinematic differences can occur at the hip without significant kinematic differences at the knee as a result of the introduction of a decline board. Further observations reinforce the role of limited ankle dorsiflexion range of motion on sagittal plane movement of the hip and knee and in turn multiplanar kinematics of the lower limb. The kinematic differences between conditions have clinical implications for screening protocols that employ frontal plane movement of the knee as a guide for femoral adduction and rotation. Subjects who returned stronger hip strength measurements also appeared to squat deeper as characterised by differences in sagittal plane kinematics of the knee and ankle. Despite the aforementioned findings, the relationship between hip strength and lower limb kinematics remains largely tenuous in the assessment of the lumbopelvic stability using the SLS. The association between kinematics and the subjective measures of lumbopelvic stability also remain tenuous between and within SLS screening protocols. More functional measures of hip strength are needed to further investigate these relationships. Conclusion: The type of SLS (flat or decline) should be taken into account when screening for lumbopelvic stability. Changes to lower limb kinematics, especially around the hip and pelvis, were observed with the introduction of a decline board despite no difference in frontal plane knee movements. Differences in passive ankle dorsiflexion range of motion yielded variations in knee and ankle kinematics during a self-selected single leg squatting task. Clinical implications of removing posterior ankle restraints and using the knee as a guide to illustrate changes at the hip may result in inaccurate screening of lumbopelvic stability. The relationship between sagittal plane lower limb kinematics and hip strength may illustrate that self-selected squat depth may presumably be a useful predictor of the lumbopelvic stability. Further research in this area is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Context Patients with venous leg ulcers experience multiple symptoms, including pain, depression, and discomfort from lower leg inflammation and wound exudate. Some of these symptoms impair wound healing and decrease quality of life (QOL). The presence of co-occurring symptoms may have a negative effect on these outcomes. The identification of symptom clusters could potentially lead to improvements in symptom management and QOL. Objectives To identify the prevalence and severity of common symptoms and the occurrence of symptom clusters in patients with venous leg ulcers. Methods For this secondary analysis, data on sociodemographic characteristics, medical history, venous history, ulcer and lower limb clinical characteristics, symptoms, treatments, healing, and QOL were analyzed from a sample of 318 patients with venous leg ulcers who were recruited from hospital outpatient and community nursing clinics for leg ulcers. Exploratory factor analysis was used to identify symptom clusters. Results Almost two-thirds (64%) of the patients experienced four or more concurrent symptoms. The most frequent symptoms were sleep disturbance (80%), pain (74%), and lower limb swelling (67%). Sixty percent of patients reported three or more symptoms at a moderate-to-severe level of intensity (e.g., 78% reported disturbed sleep frequently or always; the mean pain severity score was 49 of 100, SD 26.5). Exploratory factor analysis identified two symptom clusters: pain, depression, sleep disturbance, and fatigue; and swelling, inflammation, exudate, and fatigue. Conclusion Two symptom clusters were identified in this sample of patients with venous leg ulcers. Further research is needed to verify these symptom clusters and to evaluate their effect on patient outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Exercise has the potential to offer a range of health benefits in addition to improving healing outcomes for people with venous leg ulcers. However despite evidence based recommendations, most of these individuals do not engage in regular exercise. The aim of this study was to gain an understanding of the perspectives of adults with venous leg ulcers, in relation to exercise. Method This was a qualitative design using semi-structured interviews and discussions. Ten participants with venous leg ulceration volunteered to participate. Recruitment was through a specialist wound clinic. Verbatim data were collected by an experienced moderator using a semi-structured guide. Data saturation was reached after three group discussions and two interviews. A random selection of transcripts was sent back to the participants for verification. Thematic content analysis was used to determine major themes and categories. Two transcripts were independently analysed, categories and themes independently developed, cross checked and found comparable. Remaining transcripts were analysed using developed categories and codes. Results Regardless of their current exercise routine, participants reported exercising prior to venous leg ulceration and expressed an interest in either becoming active or maintaining an active lifestyle. Overall four themes emerged from the findings: i) participant understanding of the relationship between chronic venous insufficiency and exercise patterns, ii) fear of harm impacts upon positive beliefs and attitudes to exercise, iii) perceived factors limit exercise and iv) structured management facilitates exercise. Conclusion The value of exercise in improving outcomes in venous leg ulcers lies in its capacity to promote venous return and reduce the risk of secondary conditions in this population. Despite motivation and interest in being exercise active, people with venous leg ulcers report many obstacles. Further exploration of mechanisms that assist this patient population and promote understanding about management of barriers, coupled with promotion of enabling factors is vital for improving their exercise participation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to identify symptom clusters and their effect on quality of life (QOL) of adults with chronic leg ulcers of mixed venous and arterial aetiology. A secondary analysis of data from four existing prospective longitudinal studies conducted by a wound healing research group in Australia was undertaken. A total of 110 patients who met the inclusion criteria were selected for this study. Exploratory factor analysis (EFA) was used to identify symptom clusters and correlational analyses to examine relationships between the identified symptom clusters and QOL. The EFA identified two distinct symptom clusters: a 'systemic symptom cluster' consisting of pain, fatigue and depressive symptoms; and a 'localised-leg symptom cluster' including pain, fatigue, oedema, lower limb inflammation and exudate. Physical QOL correlated significantly with the systemic symptom cluster (r = -0·055, P < 0·0001) and the localised-leg symptom cluster (r = -0·054, P < 0·0001), whereas mental QOL was associated only with the systemic symptom cluster (r = -0·038, P = 0·01). The results suggest that appropriate intervention strategies targeting specific symptom clusters should be developed. Targeting patients with symptom clusters is particularly important because they are at high risk and the most vulnerable for reduced QOL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many factors affect the airflow patterns, thermal comfort, contaminant removal efficiency and indoor air quality at individual workstations in office buildings. In this study, four ventilation systems were used in a test chamber designed to represent an area of a typical office building floor and reproduce the real characteristics of a modern office space. Measurements of particle concentration and thermal parameters (temperature and velocity) were carried out for each of the following types of ventilation systems: a) conventional air distribution system with ceiling supply and return; b) conventional air distribution system with ceiling supply and return near the floor; c) underfloor air distribution system; and d) split system. The measurements aimed to analyse the particle removal efficiency in the breathing zone and the impact of particle concentration on an individual at the workstation. The efficiency of the ventilation system was analysed by measuring particle size and concentration, ventilation effectiveness and the Indoor/Outdoor ratio. Each ventilation system showed different airflow patterns and the efficiency of each ventilation system in the removal of the particles in the breathing zone showed no correlation with particle size and the various methods of analyses used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exhaust emissions from thirteen compressed natural gas (CNG) and nine ultralow sulphur diesel in-service transport buses were monitored on a chassis dynamometer. Measurements were carried out at idle and at three steady engine loads of 25%, 50% and 100% of maximum power at a fixed speed of 60 kmph. Emission factors were estimated for particle mass and number, carbon dioxide and oxides of nitrogen for two types of CNG buses (Scania and MAN, compatible with Euro 2 and 3 emission standards, respectively) and two types of diesel buses (Volvo Pre-Euro/Euro1 and Mercedez OC500 Euro3). All emission factors increased with load. The median particle mass emission factor for the CNG buses was less than 1% of that from the diesel buses at all loads. However, the particle number emission factors did not show a statistically significant difference between buses operating on the two types of fuel. In this paper, for the very first time, particle number emission factors are presented at four steady state engine loads for CNG buses. Median values ranged from the order of 1012 particles min-1 at idle to 1015 particles km-1 at full power. Most of the particles observed in the CNG emissions were in the nanoparticle size range and likely to be composed of volatile organic compounds The CO2 emission factors were about 20% to 30% greater for the diesel buses over the CNG buses, while the oxides of nitrogen emission factors did not show any difference due to the large variation between buses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper focuses on the development and delivery of a core construction management (CM) unit, which forms the capstone of a four-unit CM stream in an undergraduate programme in the Faculty of Built Environment and Engineering at the Queensland University of Technology. UDB410 (Construction Management) is a final year unit that consolidates skills students have learned throughout their degree, hopefully graduating them as work-ready construction managers. It was developed in consultation with the Queensland Chapter of the Australian Institute of Building (AIB) and is a final year unit in the undergraduate Bachelor of Urban Development (CM) course. The unit uses various tools such as the OSIRIS business database (Bureau van Dijk Electronic Publishing, 2009), the AROUSAL (UK Version) construction business simulation (Lansley, 2009) and the Denison Organisational Culture Survey (Denison, 2000) to facilitate the development of skills in managing a construction company. The objectives of the paper are: • To track the rationale and development of the UDB410 unit sand describe the way in which this final year unit integrates learning from other parts of the course within which it is located as well as capping-off the CM stream of core units; • To highlight the difficulties of blending a balance of technology and management in a single unit; and • To explain how partnering with the construction industry benefited the learning quality of the unit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The present study sought to identify the work destinations of graduates and ascertain their perceived preparedness for practice from a regional occupational therapy program, which had been specifically developed to support the health requirements of northern Australians by having an emphasis on rural practice. ---------- Design: Self-report questionnaires and semistructured in-depth telephone interviews. ---------- Participants: Graduates (n = 15) from the first cohort of occupational therapists from James Cook University, Queensland. ---------- Main outcome measure: The study enabled comparisons to be made between rural and urban based occupational therapists, while the semistructured interviews provided a deeper understanding of participants' experiences regarding their preparation for practice. ---------- Results: Demographic differences were noted between occupational therapists working in rural and urban settings. Rural therapists were predominantly younger and had worked in slightly more positions than their urban counterparts. The study also offered some insights into the value that therapists placed on the subjects taught during their undergraduate occupational therapy training, and had highlighted the differences in perceptions between therapists with rural experience and those with urban experience regarding the subjects that best prepared them for practice. Generally, rural therapists reported that all subjects included in the curriculum had equipped them well for practice. ---------- Conclusions: Findings suggest the need to undertake further research to determine the actual nature of rural practice, the personal characteristics of rural graduates and the experiences of students while on rural clinical placements.