44 resultados para Carcass dressing
em Queensland University of Technology - ePrints Archive
Resumo:
In children, the pain and anxiety associated with acute burn dressing changes can be severe, with drug treatment alone frequently proving to be inadequate. Virtual reality (VR) systems have been successfully trialled in limited numbers of adult and paediatric burn patients. Augmented reality (AR) differs from VR in that it overlays virtual images onto the physical world, instead of creating a complete virtual world. This prospective randomised controlled trial investigated the use of AR as an adjunct to analgesia and sedation in children with acute burns. Forty-two children (30 male and 12 female), with an age range of 3–14 years (median age 9 years) and a total burn surface area ranging from 1 to 16% were randomised into a treatment (AR) arm and a control (basic cognitive therapy) arm after administration of analgesia and/or sedation. Pain scores, pulse rates (PR), respiratory rates (RR) and oxygen saturations (SaO2) were recorded pre-procedurally, at 10 min intervals and post-procedurally. Parents were also asked to grade their child's overall pain score for the dressing change. Mean pain scores were significantly lower (p = 0.0060) in the AR group compared to the control group, as were parental pain assessment scores (p = 0.015). Respiratory and pulse rates showed significant changes over time within groups, however, these were not significantly different between the two study groups. Oxygen saturation did not differ significantly over time or between the two study groups. This trial shows that augmented reality is a useful adjunct to pharmacological analgesia.
Resumo:
The use of ultra-thin films as dressings for cutaneous wounds could prove advantageous in terms of better conformity to wound topography and improved vapour transmission. For this purpose, ultra-thin poly(epsilon-caprolactone) (PCL) films of 5-15 microm thickness were fabricated via a biaxial stretching technique. To evaluate their in vivo biocompatibility and feasibility as an external wound dressing, PCL films were applied over full and partial-thickness wounds in rat and pig models. Different groups of PCL films were used: untreated, NaOH-treated, untreated with fibrin, NaOH-treated with perforations, and NaOH-treated with fibrin and S-nitrosoglutathione. Wounds with no external dressings were used as controls. Wound contraction rate, histology and biomechanical analyses were carried out. Wounds re-epithelialized completely at a comparable rate. Formation of a neo-dermal layer and re-epithelialization were observed in all the wounds. A lower level of fibrosis was observed when PCL films were used, compared to the control wounds. Ultimate tensile strength of the regenerated tissue in rats reached 50-60% of that in native rat skin. Results indicated that biaxially-stretched PCL films did not induce inflammatory reactions when used in vivo as a wound dressing and supported the normal wound healing process in full and partial-thickness wounds.
Resumo:
Ruth Finnegan (2006, 179) describes how family myths have the power to provoke images that recur throughout generations. This paper will document my own encounter with such persistent images in the stories of a mother and daughter. Both mother and daughter told stories about encountering cross-dressing men in the streets of Brisbane, and both showed similar anxiety over their own body size. As a creative writer working with oral histories, I found these stories of the disguised body compelling. By drawing on the storytelling strategies and preoccupations present in the interview, I used imagination and fictional techniques to investigate the possibility of symbolic resonance of memories across generations. In her novel Beloved, Toni Morrison (1987) uses the notion of ‘rememory’ to describe how characters actively make and suppress meanings in their recollections. Like Morrison, my writing speaks to notions around the way stories are remembered and told.
Resumo:
MISOGYNY, no matter how it's defined, has become a political football. Fifteen minutes into the first quarter of David Williamson's Managing Carmen and Brent Lyall, a star AFL footballer, has already taken a high tackle from his hottie girlfriend, had a clanger with his manager and been caught wearing women's clothes by his acting coach. Not a good look for Brent's sponsors. By full time, Williamson's witty banter and colourful characters have hit their mark. No wonder he's already working on the screenplay.
Resumo:
We estimated the heritability and correlations between body and carcass weight traits in a cultured stock of giant freshwater prawn (GFP) (Macrobrachium rosenbergii) selected for harvest body weight in Vietnam. The data set consisted of 18,387 body and 1,730 carcass records, as well as full pedigree information collected over four generations. Variance and covariance components were estimated by restricted maximum likelihood fitting a multi-trait animal model. Across generations, estimates of heritability for body and carcass weight traits were moderate and ranged from 0.14 to 0.19 and 0.17 to 0.21, respectively. Body trait heritabilities estimated for females were significantly higher than for males whereas carcass weight trait heritabilities estimated for females and males were not significantly different (P>. 0.05). Maternal effects for body traits accounted for 4 to 5% of the total variance and were greater in females than in males. Genetic correlations among body traits were generally high in the mixed sexes. Genetic correlations between body and carcass weight traits were also high. Although some issues remain regarding the best statistical model to be fitted to GFP data, our results suggest that selection for high harvest body weight based on breeding values estimated by fitting an animal model to the data can significantly improve mean body and carcass weight in GFP.
Resumo:
BACKGROUND Silver dressings have been widely and successfully used to prevent cutaneous wounds, including burns, chronic ulcers, dermatitis and other cutaneous conditions, from infection. However, in a few cases, skin discolouration or argyria-like appearances have been reported. This study investigated the level of silver in scar tissue post-burn injury following application of Acticoat, a silver dressing. METHODS A porcine deep dermal partial thickness burn model was used. Burn wounds were treated with this silver dressing until completion of re-epithelialization, and silver levels were measured in a total of 160 scars and normal tissues. RESULTS The mean level of silver in scar tissue covered with silver dressings was 136 microg/g, while the silver level in normal skin was less than 0.747 microg/g. A number of wounds had a slate-grey appearance, and dissection of the scars revealed brown-black pigment mostly in the middle and deep dermis within the scar. The level of silver and the severity of the slate-grey discolouration were correlated with the length of time of the silver dressing application. CONCLUSIONS These results show that silver deposition in cutaneous scar tissue is a common phenomenon, and higher levels of silver deposits and severe skin discolouration are correlated with an increase in the duration of this silver dressing application.
Resumo:
We thank Dr. Burd et al. for taking an interest in our paper [1]. The retrospective cohort study was performed and published for two reasons. Firstly, we wished to compare and contrast the use of Acticoat™ and Silvazine™, and secondly we wished to demonstrate how one's practice can be dramatically altered by a change in dressing used. We found that Acticoat™ was safe and easy to use, caused less trauma to patients, required less frequent dressing changes and enabled treatment to be conducted on an outpatient, rather than an inpatient basis. During the period of Acticoat™ treatment we also saw a dramatic reduction in grafting requirements and also in the need for long-term scar management. Burd et al. correctly state that silver-based dressings are now more widely available, however many burn centres in the world continue to use silver sulphadiazine with daily baths. We therefore feel that a comparison is very relevant and useful. Prospective, randomised clinical trials of a range of silver-based dressings would indeed be useful, and hopefully Dr. Burd and colleagues will take up their own suggestion and perform these studies...
Resumo:
Patients with burn wounds are susceptible to wound infection and sepsis. This research introduces a novel burn wound dressing that contains silver nanoparticles (SNPs) to treat infection in a 2-acrylamido-2-methylpropane sulfonic acid sodium salt (AMPS-Na(+) ) hydrogel. Silver nitrate was dissolved in AMPS-Na(+) solution and then exposed to gamma irradiation to form SNP-infused hydrogels. The gamma irradiation results in a cross-linked polymeric network of sterile hydrogel dressing and a reduction of silver ions to form SNPs infused in the hydrogel in a one-step process. About 80% of the total silver was released from the hydrogels after 72 h immersion in simulated body fluid solution; therefore, they could be used on wounds for up to 3 days. All the hydrogels were found to be nontoxic to normal human dermal fibroblast cells. The silver-loaded hydrogels had good inhibitory action against Pseudomonas aeruginosa and methicillin-resistant Staphylococcus aureus. Results from a pilot study on a porcine burn model showed that the 5-mM silver hydrogel was efficient at preventing bacterial colonization of wounds, and the results were comparable to the commercially available silver dressings (Acticoat(TM) , PolyMem Silver(®) ). These results support its use as a potential burn wound dressing.
Resumo:
This paper examins the relationship between firm performance and key board and audit committee variables in a sample of mid-tier listed Australian firms. Unlike the UK where the corporate governance Code specifically outlines special arrangements for companies outside the FTSE 350 index, the ASX Corporate Governance recommendations make no special provisions for mid-tier companies. Consequently, mid-tier Australian companies may be expending scarce resources in conforming with recommendations that are not value-creating.
Resumo:
Background People admitted to intensive care units and those with chronic health care problems often require long-term vascular access. Central venous access devices (CVADs) are used for administering intravenous medications and blood sampling. CVADs are covered with a dressing and secured with an adhesive or adhesive tape to protect them from infection and reduce movement. Dressings are changed when they become soiled with blood or start to come away from the skin. Repeated removal and application of dressings can cause damage to the skin. The skin is an important barrier that protects the body against infection. Less frequent dressing changes may reduce skin damage, but it is unclear whether this practice affects the frequency of catheter-related infections. Objectives To assess the effect of the frequency of CVAD dressing changes on the incidence of catheter-related infections and other outcomes including pain and skin damage. Search methods In June 2015 we searched: The Cochrane Wounds Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE and EBSCO CINAHL. We also searched clinical trials registries for registered trials. There were no restrictions with respect to language, date of publication or study setting. Selection criteria All randomised controlled trials (RCTs) evaluating the effect of the frequency of CVAD dressing changes on the incidence of catheter-related infections on all patients in any healthcare setting. Data collection and analysis We used standard Cochrane review methodology. Two review authors independently assessed studies for inclusion, performed risk of bias assessment and data extraction. We undertook meta-analysis where appropriate or otherwise synthesised data descriptively when heterogeneous. Main results We included five RCTs (2277 participants) that compared different frequencies of CVAD dressing changes. The studies were all conducted in Europe and published between 1995 and 2009. Participants were recruited from the intensive care and cancer care departments of one children's and four adult hospitals. The studies used a variety of transparent dressings and compared a longer interval between dressing changes (5 to15 days; intervention) with a shorter interval between changes (2 to 5 days; control). In each study participants were followed up until the CVAD was removed or until discharge from ICU or hospital. - Confirmed catheter-related bloodstream infection (CRBSI) One trial randomised 995 people receiving central venous catheters to a longer or shorter interval between dressing changes and measured CRBSI. It is unclear whether there is a difference in the risk of CRBSI between people having long or short intervals between dressing changes (RR 1.42, 95% confidence interval (CI) 0.40 to 4.98) (low quality evidence). - Suspected catheter-related bloodstream infection Two trials randomised a total of 151 participants to longer or shorter dressing intervals and measured suspected CRBSI. It is unclear whether there is a difference in the risk of suspected CRBSI between people having long or short intervals between dressing changes (RR 0.70, 95% CI 0.23 to 2.10) (low quality evidence). - All cause mortality Three trials randomised a total of 896 participants to longer or shorter dressing intervals and measured all cause mortality. It is unclear whether there is a difference in the risk of death from any cause between people having long or short intervals between dressing changes (RR 1.06, 95% CI 0.90 to 1.25) (low quality evidence). - Catheter-site infection Two trials randomised a total of 371 participants to longer or shorter dressing intervals and measured catheter-site infection. It is unclear whether there is a difference in risk of catheter-site infection between people having long or short intervals between dressing changes (RR 1.07, 95% CI 0.71 to 1.63) (low quality evidence). - Skin damage One small trial (112 children) and three trials (1475 adults) measured skin damage. There was very low quality evidence for the effect of long intervals between dressing changes on skin damage compared with short intervals (children: RR of scoring ≥ 2 on the skin damage scale 0.33, 95% CI 0.16 to 0.68; data for adults not pooled). - Pain Two studies involving 193 participants measured pain. It is unclear if there is a difference between long and short interval dressing changes on pain during dressing removal (RR 0.80, 95% CI 0.46 to 1.38) (low quality evidence). Authors' conclusions The best available evidence is currently inconclusive regarding whether longer intervals between CVAD dressing changes are associated with more or less catheter-related infection, mortality or pain than shorter intervals.
Resumo:
A novel burn wound hydrogel dressing has been previously developed which is composed of 2-acrylamido-2-methylpropane sulfonic acid sodium salt with silver nanoparticles. This study compared the antimicrobial efficacy of this novel dressing to two commercially available silver dressings; Acticoat™ and PolyMem Silver(®). Three different antimicrobial tests were used: disc diffusion, broth culture, and the Live/Dead(®) Baclight™ bacterial viability assay. Burn wound pathogens (P. aeruginosa, MSSA, A. baumannii and C. albicans) and antibiotic resistant strains (MRSA and VRE) were tested. All three antimicrobial tests indicated that Acticoat™ was the most effective antimicrobial agent, with inhibition zone lengths of 13.9-18.4mm. It reduced the microbial inocula below the limit of detection (10(2)CFU/ml) and reduced viability by 99% within 4h. PolyMem Silver(®) had no zone of inhibition for most tested micro-organisms, and it also showed poor antimicrobial activity in the broth culture and Live/Dead(®) Baclight™ assays. Alarmingly, it appeared to promote the growth of VRE. The silver hydrogel reduced most of the tested microbial inocula below the detection limit and decreased bacterial viability by 94-99% after 24h exposure. These results support the possibility of using this novel silver hydrogel as a burn wound dressing in the future
Resumo:
Mobile dating applications (‘apps’) have increased in popularity over recent years, with Tinder among the first to break into the mainstream heterosexual market. Since mobile dating intensifies the need to confirm that potential dates are not misrepresenting themselves and are safe to meet in person, Tinder’s success indicates that it has allayed these concerns regarding the authenticity of its users. This article combines Giddens’ conceptualization of authenticity, as the ability to reference a coherent biographical narrative, with Callon’s sociology of translation to investigate Tinder’s framing of authenticity within mobile dating. Applying a walkthrough method that interrogates Tinder’s technological architecture, promotional materials, and related media, this hybrid theoretical framework is used to identify how Tinder configures an actor-network that establishes its app as the solution to users’ concerns, enrols individuals in using its features in authenticity claims, and popularizes Tinder’s framing across public discourse. This network of human and non-human actors frames authenticity as being established through one’s Facebook profile and adherence to normative standards relating to age, gender, ethnicity, and socioeconomic status. However, user discourses on other social media identify and challenge negative outcomes of this framing, with normativity fostering discrimination and Facebook verification failing to prevent abusive behavior. This case study of Tinder paves the way for future investigation into user responses to its framing. Further, it demonstrates the efficacy and broader applicability of this theoretical approach for identifying both human and technological influences on the construction of authenticity with digital media.
Resumo:
Uninhabited aerial vehicles (UAVs) are a cutting-edge technology that is at the forefront of aviation/aerospace research and development worldwide. Many consider their current military and defence applications as just a token of their enormous potential. Unlocking and fully exploiting this potential will see UAVs in a multitude of civilian applications and routinely operating alongside piloted aircraft. The key to realising the full potential of UAVs lies in addressing a host of regulatory, public relation, and technological challenges never encountered be- fore. Aircraft collision avoidance is considered to be one of the most important issues to be addressed, given its safety critical nature. The collision avoidance problem can be roughly organised into three areas: 1) Sense; 2) Detect; and 3) Avoid. Sensing is concerned with obtaining accurate and reliable information about other aircraft in the air; detection involves identifying potential collision threats based on available information; avoidance deals with the formulation and execution of appropriate manoeuvres to maintain safe separation. This thesis tackles the detection aspect of collision avoidance, via the development of a target detection algorithm that is capable of real-time operation onboard a UAV platform. One of the key challenges of the detection problem is the need to provide early warning. This translates to detecting potential threats whilst they are still far away, when their presence is likely to be obscured and hidden by noise. Another important consideration is the choice of sensors to capture target information, which has implications for the design and practical implementation of the detection algorithm. The main contributions of the thesis are: 1) the proposal of a dim target detection algorithm combining image morphology and hidden Markov model (HMM) filtering approaches; 2) the novel use of relative entropy rate (RER) concepts for HMM filter design; 3) the characterisation of algorithm detection performance based on simulated data as well as real in-flight target image data; and 4) the demonstration of the proposed algorithm's capacity for real-time target detection. We also consider the extension of HMM filtering techniques and the application of RER concepts for target heading angle estimation. In this thesis we propose a computer-vision based detection solution, due to the commercial-off-the-shelf (COTS) availability of camera hardware and the hardware's relatively low cost, power, and size requirements. The proposed target detection algorithm adopts a two-stage processing paradigm that begins with an image enhancement pre-processing stage followed by a track-before-detect (TBD) temporal processing stage that has been shown to be effective in dim target detection. We compare the performance of two candidate morphological filters for the image pre-processing stage, and propose a multiple hidden Markov model (MHMM) filter for the TBD temporal processing stage. The role of the morphological pre-processing stage is to exploit the spatial features of potential collision threats, while the MHMM filter serves to exploit the temporal characteristics or dynamics. The problem of optimising our proposed MHMM filter has been examined in detail. Our investigation has produced a novel design process for the MHMM filter that exploits information theory and entropy related concepts. The filter design process is posed as a mini-max optimisation problem based on a joint RER cost criterion. We provide proof that this joint RER cost criterion provides a bound on the conditional mean estimate (CME) performance of our MHMM filter, and this in turn establishes a strong theoretical basis connecting our filter design process to filter performance. Through this connection we can intelligently compare and optimise candidate filter models at the design stage, rather than having to resort to time consuming Monte Carlo simulations to gauge the relative performance of candidate designs. Moreover, the underlying entropy concepts are not constrained to any particular model type. This suggests that the RER concepts established here may be generalised to provide a useful design criterion for multiple model filtering approaches outside the class of HMM filters. In this thesis we also evaluate the performance of our proposed target detection algorithm under realistic operation conditions, and give consideration to the practical deployment of the detection algorithm onboard a UAV platform. Two fixed-wing UAVs were engaged to recreate various collision-course scenarios to capture highly realistic vision (from an onboard camera perspective) of the moments leading up to a collision. Based on this collected data, our proposed detection approach was able to detect targets out to distances ranging from about 400m to 900m. These distances, (with some assumptions about closing speeds and aircraft trajectories) translate to an advanced warning ahead of impact that approaches the 12.5 second response time recommended for human pilots. Furthermore, readily available graphic processing unit (GPU) based hardware is exploited for its parallel computing capabilities to demonstrate the practical feasibility of the proposed target detection algorithm. A prototype hardware-in- the-loop system has been found to be capable of achieving data processing rates sufficient for real-time operation. There is also scope for further improvement in performance through code optimisations. Overall, our proposed image-based target detection algorithm offers UAVs a cost-effective real-time target detection capability that is a step forward in ad- dressing the collision avoidance issue that is currently one of the most significant obstacles preventing widespread civilian applications of uninhabited aircraft. We also highlight that the algorithm development process has led to the discovery of a powerful multiple HMM filtering approach and a novel RER-based multiple filter design process. The utility of our multiple HMM filtering approach and RER concepts, however, extend beyond the target detection problem. This is demonstrated by our application of HMM filters and RER concepts to a heading angle estimation problem.
Resumo:
A collaborative approach to home care (HC) delivery for older clients has taken centre stage (Nies, 2006). In Finland, public home help and home health care services have been combined to form the home care unit, whose goal is to provide a collaborative approach to care delivery through cooperation and sharing of responsibilities. In this model, the general practitioner (GP), home care nurses (HCN) and home help workers (HHW) care for shared clients. GPs and HCNs provide health care, such as monitoring of clients’ health status, and HHWs assist with personal care tasks such as dressing, washing and meal preparation. As the needs of older clients are multiple, collaboration is needed as one professional group cannot take sole responsibility (Nies, 2006). This paper reports on a study undertaken to examine home care unit care providers’ perspectives of the collaborative approach to HC delivery for older clients.