348 resultados para Elementary particle sources


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early this year the Australian Department of Environment and Heritage commissioned a desktop literature review with a focus on ultrafine particles including analysis of health impacts of the particles as well as the impact of sulphur content of diesel fuel on ultrafine particle emission. This paper summarizes the findings of the report on the link between the sulphur content of diesel fuels and the number of ultrafine particles in diesel emissions. The literature search on this topic resulted in over 150 publications. The majority of these publications, although investigating different aspects of the influence of fuel sulphur level on diesel vehicle emissions, were not directly concerned with ultrafine particle emissions. A specific focus of the paper is on: ----- ----- summary of state of knowledge established by the review, and ----- ----- summary of recommendations on the research priorities for Australia to address the information gaps for this issue, and on the appropriate management responses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As part of a larger indoor environmental study, residential indoor and outdoor levels of nitrogen dioxide (NO2) were measured for 14 houses in a suburb of Brisbane, Queensland, Australia. Passive samplers were used for 48-h sampling periods during the winter of 1999. The average indoor and outdoor NO2 levels were 13.8 ± 6.3 and 16.7 ± 4.2 ppb, respectively. The indoor/outdoor NO2 concentration ratio ranged from 0.4 to 2.3, with a median value of 0.82. The results of statistic analyses indicated that there was no significant correlation between indoor and outdoor NO2 concentrations, or between indoor and fixed site NO2 monitoring station concentrations. However, there was a significant correlation between outdoor and fixed site NO2 monitoring station concentrations. There was also a significant correlation between indoor NO2 concentration and indoor submicrometre (0.007–0.808 μm) aerosol particle number concentrations. The results in this study indicated indoor NO2 levels are significantly affected by indoor NO2 sources, such as a gas stove and cigarette smoking. It implies that the outdoor or fixed site monitoring concentration alone is a poor predictor of indoor NO2 concentration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Road deposited solids are a mix of pollutants originating from a range of anthropogenic sources common to urban land uses and soil inputs from surrounding areas. These particles accumulate potentially toxic pollutants thereby posing a threat to receiving waters. Reliable estimation of sources of particulate pollutants in build-up and quantification of particle composition is important for the development of best management practices for stormwater quality mitigation. The research study analysed build-up pollutants from sixteen different urban road surfaces and soil from four background locations. The road surfaces were selected from residential, industrial and commercial land uses from four suburbs in Gold Coast, Australia. Collected build-up samples were analysed for solids load, organic matter and mineralogy. The soil samples were analysed for mineralogy. Quantitative and qualitative analysis of mineralogical data, along with multivariate data analysis were employed to identify the relative source contributions to road deposited solids. The build-up load on road surfaces in different suburbs showed significant differences due to the nature of anthropogenic activities, road texture depth and antecedent dry period. Analysis revealed that build-up pollutants consists primarily of soil derived minerals (60%) and the remainder is composed of traffic generated pollutants and organic matter. Major mineral components detected were quartz and potential clay forming minerals such as albite, microline, chlorite and muscovite. An average of 40-50% of build-up pollutants by weight was made up of quartz. Comparison of the mineral component of build-up pollutants with background soil samples indicated that the minerals primarily originate from surrounding soils. About 2.2% of build-up pollutants were organic matter which originates largely from plant matter. Traffic related pollutants which are potentially toxic to the receiving water environment represented about 30% of the build-up pollutants at the study sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Signal Processing (SP) is a subject of central importance in engineering and the applied sciences. Signals are information-bearing functions, and SP deals with the analysis and processing of signals (by dedicated systems) to extract or modify information. Signal processing is necessary because signals normally contain information that is not readily usable or understandable, or which might be disturbed by unwanted sources such as noise. Although many signals are non-electrical, it is common to convert them into electrical signals for processing. Most natural signals (such as acoustic and biomedical signals) are continuous functions of time, with these signals being referred to as analog signals. Prior to the onset of digital computers, Analog Signal Processing (ASP) and analog systems were the only tool to deal with analog signals. Although ASP and analog systems are still widely used, Digital Signal Processing (DSP) and digital systems are attracting more attention, due in large part to the significant advantages of digital systems over the analog counterparts. These advantages include superiority in performance,s peed, reliability, efficiency of storage, size and cost. In addition, DSP can solve problems that cannot be solved using ASP, like the spectral analysis of multicomonent signals, adaptive filtering, and operations at very low frequencies. Following the recent developments in engineering which occurred in the 1980's and 1990's, DSP became one of the world's fastest growing industries. Since that time DSP has not only impacted on traditional areas of electrical engineering, but has had far reaching effects on other domains that deal with information such as economics, meteorology, seismology, bioengineering, oceanology, communications, astronomy, radar engineering, control engineering and various other applications. This book is based on the Lecture Notes of Associate Professor Zahir M. Hussain at RMIT University (Melbourne, 2001-2009), the research of Dr. Amin Z. Sadik (at QUT & RMIT, 2005-2008), and the Note of Professor Peter O'Shea at Queensland University of Technology. Part I of the book addresses the representation of analog and digital signals and systems in the time domain and in the frequency domain. The core topics covered are convolution, transforms (Fourier, Laplace, Z. Discrete-time Fourier, and Discrete Fourier), filters, and random signal analysis. There is also a treatment of some important applications of DSP, including signal detection in noise, radar range estimation, banking and financial applications, and audio effects production. Design and implementation of digital systems (such as integrators, differentiators, resonators and oscillators are also considered, along with the design of conventional digital filters. Part I is suitable for an elementary course in DSP. Part II (which is suitable for an advanced signal processing course), considers selected signal processing systems and techniques. Core topics covered are the Hilbert transformer, binary signal transmission, phase-locked loops, sigma-delta modulation, noise shaping, quantization, adaptive filters, and non-stationary signal analysis. Part III presents some selected advanced DSP topics. We hope that this book will contribute to the advancement of engineering education and that it will serve as a general reference book on digital signal processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A basic understanding of the relationships between rainfall intensity, duration of rainfall and the amount of suspended particles in stormwater runoff generated from road surfaces has been gained mainly from past washoff experiments using rainfall simulators. Simulated rainfall was generally applied at constant intensities, whereas rainfall temporal patterns during actual storms are typically highly variable. This paper discusses a rationale for the application of the constant-intensity washoff concepts to actual storm event runoff. The rationale is tested using suspended particle load data collected at a road site located in Toowoomba, Australia. Agreement between the washoff concepts and measured data is most consistent for intermediate-duration storms (duration <5 h and >1 h). Particle loads resulting from these storm events increase linearly with average rainfall intensity. Above a threshold intensity, there is evidence to suggest a constant or plateau particle load is reached. The inclusion of a peak discharge factor (maximum 6 min rainfall intensity) enhances the ability to predict particle loads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Not all cancer patients receive state-of-the-art care and providing regular feedback to clinicians might reduce this problem. The purpose of this study was to assess the utility of various data sources in providing feedback on the quality of cancer care. Methods Published clinical practice guidelines were used to obtain a list of processes-of-care of interest to clinicians. These were assigned to one of four data categories according to their availability and the marginal cost of using them for feedback. Results Only 8 (3%) of 243 processes-of-care could be measured using population-based registry or administrative inpatient data (lowest cost). A further 119 (49%) could be measured using a core clinical registry, which contains information on important prognostic factors (e.g., clinical stage, physiological reserve, hormone-receptor status). Another 88 (36%) required an expanded clinical registry or medical record review; mainly because they concerned long-term management of disease progression (recurrences and metastases) and 28 (11.5%) required patient interview or audio-taping of consultations because they involved information sharing between clinician and patient. Conclusion The advantages of population-based cancer registries and administrative inpatient data are wide coverage and low cost. The disadvantage is that they currently contain information on only a few processes-of-care. In most jurisdictions, clinical cancer registries, which can be used to report on many more processes-of-care, do not cover smaller hospitals. If we are to provide feedback about all patients, not just those in larger academic hospitals with the most developed data systems, then we need to develop sustainable population-based data systems that capture information on prognostic factors at the time of initial diagnosis and information on management of disease progression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single particle analysis (SPA) coupled with high-resolution electron cryo-microscopy is emerging as a powerful technique for the structure determination of membrane protein complexes and soluble macromolecular assemblies. Current estimates suggest that ∼104–105 particle projections are required to attain a 3 Å resolution 3D reconstruction (symmetry dependent). Selecting this number of molecular projections differing in size, shape and symmetry is a rate-limiting step for the automation of 3D image reconstruction. Here, we present SwarmPS, a feature rich GUI based software package to manage large scale, semi-automated particle picking projects. The software provides cross-correlation and edge-detection algorithms. Algorithm-specific parameters are transparently and automatically determined through user interaction with the image, rather than by trial and error. Other features include multiple image handling (∼102), local and global particle selection options, interactive image freezing, automatic particle centering, and full manual override to correct false positives and negatives. SwarmPS is user friendly, flexible, extensible, fast, and capable of exporting boxed out projection images, or particle coordinates, compatible with downstream image processing suites.