156 resultados para Elective ventilation
Resumo:
OBJECTIVE: To synthesise the available evidence and estimate the comparative efficacy of control strategies to prevent total hip replacement (THR)-related surgical site infections (SSIs) using a mixed treatment comparison. DESIGN: Systematic review and mixed treatment comparison. SETTING: Hospital and other healthcare settings. PARTICIPANTS: Patients undergoing THR. PRIMARY AND SECONDARY OUTCOME MEASURES: The number of THR-related SSIs occurring following the surgical operation. RESULTS: 12 studies involving 123 788 THRs and 9 infection control strategies were identified. The strategy of 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation' significantly reduced the risk of THR-related SSI compared with the referent strategy (no systemic antibiotics+plain cement+conventional ventilation), OR 0.13 (95% credible interval (CrI) 0.03-0.35), and had the highest probability (47-64%) and highest median rank of being the most effective strategy. There was some evidence to suggest that 'systemic antibiotics+antibiotic-impregnated cement+laminar airflow' could potentially increase infection risk compared with 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation', 1.96 (95% CrI 0.52-5.37). There was no high-quality evidence that antibiotic-impregnated cement without systemic antibiotic prophylaxis was effective in reducing infection compared with plain cement with systemic antibiotics, 1.28 (95% CrI 0.38-3.38). CONCLUSIONS: We found no convincing evidence in favour of the use of laminar airflow over conventional ventilation for prevention of THR-related SSIs, yet laminar airflow is costly and widely used. Antibiotic-impregnated cement without systemic antibiotics may not be effective in reducing THR-related SSIs. The combination with the highest confidence for reducing SSIs was 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation'. Our evidence synthesis underscores the need to review current guidelines based on the available evidence, and to conduct further high-quality double-blind randomised controlled trials to better inform the current clinical guidelines and practice for prevention of THR-related SSIs.
Resumo:
AIM The aim of this paper was to review the current discourse in relation to intensive care unit (ICU) delirium. In particular, it will discuss the predisposing and contributory factors associated with delirium's development as well as effects of delirium on patients, staff and family members. BACKGROUND Critically ill patients are at greater risk of developing delirium and, with an ageing population and increased patient acuity permitted by medical advances, delirium is a growing problem in the ICU. However, there is a universal consensus that the definition of ICU delirium needs improvement to aid its recognition and to ensure both hypoalert-hypoactive and hyperalert-hyperactive variants are easily and readily identified. RELEVANCE TO CLINICAL PRACTICE The effects of ICU delirium have cost implications to the National Health Service in terms of prolonged ventilation and length of hospital stay. The causes of delirium can be readily classified as either predisposing or precipitating factors, which are organic in nature and commonly reversible. However, contributory factors also exist to exacerbate delirium and having an awareness of all these factors promises to aid prevention and expedite treatment. This will avoid or limit the host of adverse physiological and psychological consequences that delirium can provoke and directly enhance both patient and staff safety. CONCLUSIONS Routine screening of all patients in the ICU for the presence of delirium is crucial to its successful management. Nurses are on the front line to detect, manage and even prevent delirium.
Resumo:
Background: Tradition has led us to believe that a heavily sedated patient is a comfortable, settled, compliant patient for whom sedation will improve outcome. The current move witnessed in clinical practice today of limiting sedation has led health care in recent years to question the benefit and necessity of routine, continuous sedation for all patients requiring mechanical ventilation. However, as a result there has been a rise in the amount of agitation being reported as being experienced by patients with the daily withdrawal of sedation. Aims: The purpose of this paper is to review current arguments for and against perserving with agitation versus re-sedating, when it presents during the daily sedation breaks. Findings: Of the literature reviewed, the question to re-sedate the mechanically ventilated agitated patient during sedation breaks remains an issue of contention. Although there is evidence focusing on the psychological effects of long-term sedation and sedation breaks specifically, the complex nature of critical illness in some cases means that individualized care is of paramount importance and in-depth assessment is crucial when deciding to re-sedate in the face of undetermined agitation. Agitation has been closely linked with several incidents that can be detrimental to patient safety, such as removal of lines and unplanned self-extubation. Conclusion: The recommendations of this review are that nurses should re-commence sedation if the patient becomes agitated following a sedation break. Aims: The purpose of this paper is to review current arguments for and against perserving with agitation versus re-sedating, when it presents during the daily sedation breaks. Findings: Of the literature reviewed, the question to re-sedate the mechanically ventilated agitated patient during sedation breaks remains an issue of contention. Although there is evidence focusing on the psychological effects of long-term sedation and sedation breaks specifically, the complex nature of critical illness in some cases means that individualized care is of paramount importance and in-depth assessment is crucial when deciding to re-sedate in the face of undetermined agitation. Agitation has been closely linked with several incidents that can be detrimental to patient safety, such as removal of lines and unplanned self-extubation. Conclusion: The recommendations of this review are that nurses should re-commence sedation if the patient becomes agitated following a sedation break.
Resumo:
Emphysema is caused by exposure to cigarette smoking as well as alpha1-antitrypsin deficiency. It has been estimated to cost the National Health Service (NHS) in excess of £800 million per year in related health care costs. The challenges for Critical Care nurses are those associated with dynamic hyperinflation, Auto-PEEP, malnutrition and the weaning from invasive and non-invasive mechanical ventilation. In this paper we consider the impact of the pathophysiology of emphysema, its effects on other body systems as well as the impact acute exacerbations have when patients are admitted to the Intensive Care Unit.
Resumo:
This is the protocol for a review and there is no abstract. The objectives are as follows: To determine the evidence supporting the use of recruitment manoeuvres in mechanically ventilated neonates and identify the optimal method of lung recruitment. To determine the effects of lung recruitment manoeuvres in neonates receiving ventilatory support on neonatal mortality and development of chronic lung disease when compared to no recruitment. If data are available, subgroup analyses will include: chronological age, gestational age, lung pathophysiology and pre-existing lung disease, mode and length of ventilation, timing and frequency of recruitment techniques.
Resumo:
In extreme weather conditions, thrusters on ships and rigs may be subject to severe thrust losses caused by ventilation and in-and-out-of-water events. When a thruster ventilates, air is sucked down from the surface and into the propeller. In more severe cases, parts of or even the whole propeller can be out of the water. These losses vary rapidly with time and cause increased wear and tear in addition to reduced thruster performance. In this paper, a thrust allocation strategy is proposed to reduce the effects of thrust losses and to reduce the possibility of multiple ventilation events. This thrust allocation strategy is named antispin thrust allocation, based on the analogous behavior of antispin wheel control of cars. The proposed thrust allocation strategy is important for improving the life span of the propulsion system and the accuracy of positioning for vessels conducting station keeping in terms of dynamic positioning or thruster-assisted position mooring. Application of this strategy can result in an increase of operational time and, thus, increased profitability. The performance of the proposed allocation strategy is demonstrated with experiments on a model ship.
Resumo:
This work investigated the impact of the HVAC filtration system and indoor particle sources on the relationship between indoor and outdoor airborne particle size and concentrations in an operating room. Filters with efficiency between 65% and 99.97% were used in the investigation and indoor and outdoor particle size and concentrations were measured. A balance mass model was used for the simulation of the impact of the surgical team, deposition rate, HVAC exhaust and air change rates on indoor particle concentration. The experimental results showed that high efficiency filters would not be expected to decrease the risk associated with indoor particles larger than approximately 1 µm in size because normal filters are relatively efficient for these large particles. A good fraction of outdoor particles were removed by deposition on the HVAC system surfaces and this deposition increased with particle size. For particles of 0.3-0.5 µm in diameter, particle reduction was about 23%, while for particles >10 µm the loss was about 78%. The modelling results showed that depending on the type of filter used, the surgical team generated between 93-99% of total particles, while the outdoor air contributed only 1-6%.
Resumo:
Aims Although suctioning is a standard airway maintenance procedure, there are significant associated risks, such as loss of lung volume due to high negative suction pressures. This study aims to assess the extent and duration of change in end-expiratory level (EEL) resulting from endotracheal tube (ETT) suction and to examine the relationship between EEL and regional lung ventilation in ventilated preterm infants with respiratory distress syndrome. Methods A prospective observational clinical study of the effect of ETT suction on 20 non-muscle-relaxed preterm infants with respiratory distress syndrome (RDS) on conventional mechanical ventilation was conducted in a neonatal intensive care unit. Ventilation distribution was measured with regional impedance amplitudes and EEL using electrical impedance tomography. Results ETT suction resulted in a significant increase in EEL post-suction (P < 0.01). Regionally, anterior EEL decreased and posterior EEL increased post-suction, suggesting heterogeneity. Tidal volume was significantly lower in volume-guarantee ventilation compared with pressure-controlled ventilation (P = 0.04). Conclusions ETT suction in non-muscle-relaxed and ventilated preterm infants with RDS results in significant lung volume increase that is maintained for at least 90 min. Regional differences in distribution of ventilation with ETT suction suggest that the behaviour of the lung is heterogeneous in nature.
Resumo:
The aim of this work was to investigate changes in particle number concentration (PNC) within naturally ventilated primary school classrooms arising from local sources either within or adjacent to the classrooms. We quantify the rate at which ultrafine particles were emitted either from printing, grilling, heating or cleaning activities and the rate at which the particles were removed by both deposition and air exchange processes. At each of 25 schools in Brisbane, Australia, two weeks of measurements of PNC and CO2 were taken both outdoors and in the two classrooms. Bayesian regression modelling was employed in order to estimate the relevant rates and analyse the relationship between air exchange rate (AER), particle infiltration and the deposition rates of particle generated from indoor activities in the classrooms. During schooling hours, grilling events at the school tuckshop as well as heating and printing in the classrooms led to indoor PNCs being elevated by a factor of more than four, with emission rates of (2.51 ± 0.25) x 1011 p min-1, (8.99 ± 6.70) x 1011 p min-1 and (5.17 ± 2.00) x 1011 p min-1, respectively. During non-school hours, cleaning events elevated indoor PNC by a factor of above five, with an average emission rate of (2.09 ± 6.30) x 1011 p min-1. Particles were removed by both air exchange and deposition; chiefly by ventilation when AER > 0.7 h-1 and by deposition when AER < 0.7 h-1.
Resumo:
The built environment has a profound impact on our natural environment, economy, health and productivity. As the majority of the people spent most of their time inside buildings, the environment in which they perform their daily activities will have an impact on their health and productivity. Studies have been conducted about the negative impacts of presence of non-favorable conditions to human health and well being. The term "Sick Building Syndrome" (SBS) is used to describe situations in which building occupants experience acute health and comfort problems that appear to be linked to their time spent in a building. Sustainable infrastructure rating systems have requirements intended to improve occupant productivity and health.While the impact of Sustainable Infrastructure in energy consumption and waste/water reduction can be measured using available tools, the impact on productivity remained as an assumption that is not clearly measured. The purpose of this research is to develop a framework to assess whether the impacts of the incorporation of features intended to improve occupants’ performance and health such as: increased ventilation, lightning and thermal comfort serve their intended purpose.
Resumo:
Background Person-to-person transmission of respiratory pathogens, including Pseudomonas aeruginosa, is a challenge facing many cystic fibrosis (CF) centres. Viable P aeruginosa are contained in aerosols produced during coughing, raising the possibility of airborne transmission. Methods Using purpose-built equipment, we measured viable P aeruginosa in cough aerosols at 1, 2 and 4 m from the subject (distance) and after allowing aerosols to age for 5, 15 and 45 min in a slowly rotating drum to minimise gravitational settling and inertial impaction (duration). Aerosol particles were captured and sized employing an Anderson Impactor and cultured using conventional microbiology. Sputum was also cultured and lung function and respiratory muscle strength measured. Results Nineteen patients with CF, mean age 25.8 (SD 9.2) years, chronically infected with P aeruginosa, and 10 healthy controls, 26.5 (8.7) years, participated. Viable P aeruginosa were detected in cough aerosols from all patients with CF, but not from controls; travelling 4 m in 17/18 (94%) and persisting for 45 min in 14/18 (78%) of the CF group. Marked inter-subject heterogeneity of P aeruginosa aerosol colony counts was seen and correlated strongly (r=0.73–0.90) with sputum bacterial loads. Modelling decay of viable P aeruginosa in a clinic room suggested that at the recommended ventilation rate of two air changes per hour almost 50 min were required for 90% to be removed after an infected patient left the room. Conclusions Viable P aeruginosa in cough aerosols travel further and last longer than recognised previously, providing additional evidence of airborne transmission between patients with CF.
Resumo:
Background Current evidence to support non-medical prescribing is predominantly qualitative, with little evaluation of appropriateness. This study aims to evaluate the appropriateness of prescribing, and significance of omissions, from a doctor pharmacist collaborative prescribing model in an elective surgery pre admission clinic (PAC). Method A modified version of the Medication Appropriate Index (MAI) was developed, piloted and subsequently used by an expert panel, comprised of a surgeon, anaesthetist, clinical pharmacologist, pharmacist, resident medical officer (RMO) and clinical nurse. The tool was used to rate the appropriateness of prescribing of medications, and the significance of omissions in a 5% sample (N=19) of the total cohort from a randomised, controlled two arm trial of doctor-pharmacist collaborative prescribing. Results When reviewer assessments were combined, 32 out of 294 (10.9%) medications assessed for appropriateness in the control arm were classed as inappropriate, compared to 13 of 266 (4.9%) in the intervention arm. Out of 89 regular medications in the control arm, 25 (28%) were omitted from the medication charts, compared to 1 out of 55 (2%) in the intervention arm (p<0.001, fishers exact) On average, 52% of omissions in the control arm were judged to have potential for patient harm or ward inconvenience. Conclusion For the appropriateness of prescribing, overall results were similar between arms, as judged by individual panel members. Medication charts in the control arm contained significantly more omissions than in the intervention arm, a number of which were rated by the panel members as having the potential for patient harm or ward inconvenience.
Resumo:
This was a comparative study of the possibility of a net zero energy house in Queensland, Australia. It examines the actual energy use and thermal comfort conditions of an occupied Brisbane home and compares performance with the 10 star scale rating scheme for Australian residential buildings. An adaptive comfort psychometric chart was developed for this analysis. The house's capacity for the use of the natural ventilation was studied by CFD modelling. This study showed that the house succeeded in achieving the definition of net zero energy on an annual and monthly basis for lighting, cooking and space heating / cooling and for 70% of days for lighting, hot water and cooking services.
Resumo:
Fire resistance rating of light gauge steel frame (LSF) wall systems is obtained from fire tests based on the standard fire time-temperature curve. However, fire severity has increased in modern buildings due to higher fuel loads as a result of modern furniture and light weight constructions that make use of thermoplastics materials, synthetic foams and fabrics. Some of these materials are high in calorific values and increase both the spread of fire growth and heat release rate, thus increasing the fire severity beyond that of the standard fire curve. Further, the standard fire curve does not include a decay phase that is present in natural fires. Despite the increasing usage of LSF walls, their behaviour in real building fires is not fully understood. This paper presents the details of a research study aimed at developing realistic design fire curves for use in the fire tests of LSF walls. It includes a review of the characteristics of building fires, previously developed fire time-temperature curves, computer models and available parametric equations. The paper highlights that real building fire time-temperature curves depend on the fuel load representing the combustible building contents, ventilation openings and thermal properties of wall lining materials, and provides suitable values of many required parameters including fuel loads in residential buildings. Finally, realistic design fire time-temperature curves simulating the fire conditions in modern residential buildings are proposed for the testing of LSF walls.
Resumo:
Hospitals invest considerable resources organizing operating suites and having surgeons and theatre staff available on an agreed schedule. A common impediment to efficiency is perioperative delay,including delays getting to the operating room or during the operation. Perioperative delays entail significant costs for hospitals,wasting staff time and operating theatre resources. They may also affect patient outcomes; prolonged surgery is a predictor for unanticipated admission following elective ambulatory surgery...