152 resultados para <0.2 µm
Resumo:
Background Anaemia is common in critically ill patients, and has a significant negative impact on patients' recovery. Blood conservation strategies have been developed to reduce the incidence of iatrogenic anaemic caused by sampling for diagnostic testing. Objectives Describe practice and local guidelines in adult, paediatric and neonatal Australian intensive care units (ICUs) regarding blood sampling and conservation strategies. Methods Cross-sectional descriptive study, conducted July 2013 over one week in single adult, paediatric and neonatal ICUs in Brisbane. Data were collected on diagnostic blood samples obtained during the study period, including demographic and acuity data of patients. Institutional blood conservation practice and guidelines were compared against seven evidence-based recommendations. Results A total of 940 blood sampling episodes from 96 patients were examined across three sites. Arterial blood gas was the predominant reason for blood sampling in each unit, accounting for 82% of adult, 80% of paediatric and 47% of neonatal samples taken (p <. 0.001). Adult patients had significantly more median [IQR] samples per day in comparison to paediatrics and neonates (adults 5.0 [2.4]; paediatrics 2.3 [2.9]; neonatal 0.7 [2.7]), which significantly increased median [IQR] blood sampling costs per day (adults AUD$101.11 [54.71]; paediatrics AUD$41.55 [56.74]; neonatal AUD$8.13 [14.95]; p <. 0.001). The total volume of samples per day (median [IQR]) was also highest in adults (adults 22.3. mL [16.8]; paediatrics 5.0. mL [1.0]; neonates 0.16. mL [0.4]). There was little information about blood conservation strategies in the local clinical practice guidelines, with the adult and neonatal sites including none of the seven recommendations. Conclusions There was significant variation in blood sampling practice and conservation strategies between critical care settings. This has implications not only for anaemia but also infection control and healthcare costs.
Resumo:
This study investigated a potential source of inaccuracy for diode measurements in modulated beams; the effect of diode housing asymmetry on measurement results. The possible effects of diode housing asymmetry on the measurement of steep dose gradients were evaluated by measuring 5x5 cm2 beam profiles, with three cylindrical diodes and two commonly used ionization chambers, with each dosimeter positioned in a 3D scanning water tank with its stem perpendicular to the beam axis (horizontal) and parallel to the direction of scanning. The resulting profiles were used to compare the penumbrae measured with the diode stem pointing into (equivalent to a “stem-first” setup) and out of the field (equivalent to a “stem-last” setup) in order to evaluate the effects of dosimeter alignment and thereby identify the effects of dosimeter asymmetry. The stem-first and stem-last orientations resulted in differences of up to 0.2 mm in the measured 20-80% penumbra widths and differences of up to 0.4 mm in the off axis position of the 90% isodose. These differences, which are smaller than previously reported for older model dosimeters, were apparent in the profile results for both diodes and small volume ionization chambers. As an extension to this study, the practical use of all five dosimeters was exemplified by measuring point doses in IMRT test beams. These measurements showed good agreement (within 2%) between the diodes and the small volume ionization chamber, with all of these dosimeters being able to identify a region 3% under-dosage which was not identified by a larger volume (6 mm diameter) ionization chamber. The results of this work should help to remove some of the barriers to the use of diodes for modulated radiotherapy dosimetry in the future.
Resumo:
Objective: To evaluate the effects of exercise on cancer-related lymphedema and related symptoms, and to determine the need for those with lymphedema to wear compression during exercise. Data Sources: CINAHL, Cochrane, Ebscohost, MEDLINE, Pubmed, ProQuest Health and Medical Complete, ProQuest Nursing and Allied Health Source, Science Direct and SPORTDiscus databases were searched for trials published prior to 1 January, 2015. Study Selection: Randomised and non-randomised, controlled trials, and single group pre-post studies published in English-language were included. Twenty-one (exercise) and four (compression and exercise) studies met inclusion criteria. Data Extraction: Data was extracted into tabular format using predefined data fields by one reviewer and assessed for accuracy by a second reviewer. Study quality was evaluated using the Effective Public Health Practice Project assessment tool. Data Synthesis: Data was pooled using a random effects model to assess the effects of acute and long-term exercise on lymphedema and lymphedema-associated symptoms, with subgroup analyses for exercise mode and intervention length. There was no effect of exercise (acute or intervention) on lymphedema or associated symptoms with standardised mean differences from all analyses ranging between −0.2 and 0.1 (p-values ≥0.22). Findings from subgroup analyses for exercise mode (aerobic, resistance, mixed, other) and intervention duration (>12 weeks or ≤12 weeks) were consistent with these findings; that is, no effect on lymphedema or associated symptoms. There were too few studies evaluating the effect of compression during regular exercise to conduct a meta-analysis. Conclusions: Individuals with secondary lymphedema can safely participate in progressive, regular exercise without experiencing a worsening of lymphedema or related-symptoms. However, the results also do not suggest any improvements will occur in lymphedema. At present, there is insufficient evidence to support or refute the current clinical recommendation to wear compression garments during regular exercise.
Resumo:
Background: The genome-wide association study era has made great progress in identifying susceptibility genes and genetic loci for rheumatoid arthritis (RA) in populations of White European ancestry. However, few studies have tried to dissect disease aetiopathogenesis in other ethnic populations. Objective: To investigate these associations in the Han Chinese population. Methods: Haplotypes from the HapMap database Chinese population were used to select tag-single-nucleotide polymorphisms (SNPs) (r2 =0.8) across 19 distinct RA genomic regions. A two phase case-control association study was performed, with 169 SNPs genotyped in phase I (n=571 cases, n=880 controls), and 64 SNPs achieving p<0.2 in the first phase being genotyped in phase II (n=464 cases, n=822 controls). Association statistics were calculated using permutation tests both unadjusted and adjusted for the number of markers studied. Results: Robust association was detected for MMEL1 and CTLA4 , and modest association was identified for another six loci: PADI4 , STAT4 , PRDM1 , CDK6 , TRAF1-C5 and KIF5A-PIP4K2C. All three markers genotyped in MMEL1 demonstrated association, with peak signal for rs3890745 (p=2.6×10 -5unadjusted, p=0.003 adjusted, OR=0.79). For CTLA4 , significance was detected for three of five variants showing association, with peak association for marker rs12992492 (p=4.3×10-5 unadjusted, p=0.0021 adjusted, OR=0.77). Lack of association of common variants in PTPN22 with RA in Han Chinese was confirmed. Conclusion: This study identifies MMEL1 and CTLA4 as RA susceptibility genes, provides suggestive evidence of association for a further six loci in the Han Chinese population and confirms lack of PTPN22 association in Asian populations. It also confirms the value of multiethnic population studies to help dissect disease aetiopathogenesis.
Resumo:
Objectives: To assess the possible association of killer immunoglobulin-like receptor (KIR) genes, specifically KIR3DL1, KIR3DS1 and KIR3DL2, with ankylosing spondylitis (AS). Methods: 14 KIR genes were genotyped in 200 UK patients with AS and 405 healthy controls using multiplex polymerase chain reaction. Sequence-specific oligonucleotide probes were used to subtype 368 cases with AS and 366 controls for 12 KIR3DL2 alleles. Differences in KIR genotypes and KIR3DL2 allele frequencies were assessed using the χp2p test. Results: KIR3DL1 and KIR3DS1 gene frequencies were very similar in cases with AS and controls (odds ratio = 1.5, 95% confidence interval 0.8 to 3.0, and odds ratio = 1.02, 95% confidence interval 0.2 to 5.3, respectively). KIR3DL2 allele frequencies were not significantly different between cases with AS and controls. Conclusions: Neither the KIR gene content of particular KIR haplotypes nor KIR3DL2 polymorphisms contribute to AS.
Resumo:
Objectives: To investigate the association of the FcγRIIIA gene with rheumatoid orthritis (RA) in two genetically distinct groups: a white group from the United Kingdom and a northern Indian group. Methods: The distributions of the two alleles of the FcγRIIIA F158V polymorphism were determined in 398 white patients from the United Kingdom and 63 Indian patients with RA and compared with those from 289 United Kingdom and 93 Indian healthy controls, respectively. Results: Among the Indian patients, the frequency of the rare 158V allele and the proportion of 158VV homozygotes were reduced (relative risk (RR)=0.3, 95% confidence interval (95% CI) 0.1 to 1.1, p<0.06), reaching statistical significance for carrying the 158VV phenotype relative to 158FV or FF (RR=0.2, 95% CI 0.05-0.9, p<0.02). Conversely, no significant deviation in allelic frequencies was noted between the patients and controls from the United Kingdom. Conclusions: The 158VV phenotype showed a weak protective effect against developing RA in the Indian group. However, this sample was small (resulting in a low power for statistical analysis) and no independent confirmation was found in the larger white United Kingdom group. Thus the FcγRIIIA locus is unlikely to be of major importance in causing RA.
Resumo:
Objective. To analyze the effect of HLA-DR genes on susceptibility to and severity of ankylosing spondylitis (AS). Methods. Three hundred sixty- three white British AS patients were studied; 149 were carefully assessed for a range of clinical manifestations, and disease severity was assessed using a structured questionnaire. Limited HLA class I typing and complete HLA-DR typing were performed using DNA-based methods. HLA data from 13,634 healthy white British bone marrow donors were used for comparison. Results. A significant association between DR1 and AS was found, independent of HLA-B27 (overall odds ratio [OR] 1.4, 95% confidence interval [95% CI] 1.1-1.8, P = 0.02; relative risk [RR] 2.7, 95% CI 1.5-4.8, P = 6 x 10-4 among homozygotes; RR 2.1, 95% CI 1.5-2.8, P = 5 x 10-6 among heterozygotes). A large but weakly significant association between DR8 and AS was noted, particularly among DR8 homozygotes (RR 6.8, 95% CI 1.6-29.2, P = 0.01 among homozygotes; RR 1.6, 95% CI 1.0-2.7, P = 0.07 among heterozygotes). A negative association with DR12 (OR 0.22, 95% CI 0.09-0.5, P = 0.001) was noted. HLA-DR7 was associated with younger age at onset of disease (mean age at onset 18 years for DR7-positive patients and 23 years for DR7-negative patients; Z score 3.21, P = 0.001). No other HLA class I or class H associations with disease severity or with different clinical manifestations of AS were found. Conclusion. The results of this study suggest that HLA-DR genes may have a weak effect on susceptibility to AS independent of HLA-B27, but do not support suggestions that they affect disease severity or different clinical manifestations.
Resumo:
Objective. To assess the role of genes and the environment in determining the severity of ankylosing spondylitis. Methods: One hundred seventy-three families with >1 case of ankylosing spondylitis were recruited (120 affected sibling pairs, 26 affected parent-child pairs, 20 families with both first- and second-degree relatives affected, and 7 families with only second-degree relatives affected), comprising a total of 384 affected individuals. Disease severity was assessed by the Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) and functional impairment was determined using the Bath Ankylosing Spondylitis Functional Index (BASFI). Disease duration and age at onset were also studied. Variance-components modeling was used to determine the genetic and environmental components Contributing to familiality of the traits examined, and complex segregation analysis was performed to assess different disease models. Results. Both the disease activity and functional capacity as assessed by the BASDAI and the BASFI, respectively, were found to be highly familial (BASDAI familiality 0.51 [P = 10-4], BASFI familiality 0,68 [P = 3 × 10-7]). No significant shared environmental component was demonstrated to be associated with either the BASDAI or the BASFI. Including age at disease onset and duration of disease as covariates made no difference in the heritability assessments. A strong correlation was noted between the BASDAI and the BASFI (genetic correlation 0.9), suggesting the presence of shared determinants of these 2 measures. However, there was significant residual heritability for each measure independent of the other (BASFI residual heritability 0.48, BASDAI 0,36), perhaps indicating that not all genes influencing disease activity influence chronicity. No significant heritability of age at disease onset was found (heritability 0.18; P = 0.2). Segregation studies suggested the presence of a single major gene influencing the BASDAI and the BASFI. Conclusion. This study demonstrates a major genetic contribution to disease severity in ankylosing spondylitis. As with susceptibility to ankylosing spondylitis, shared environmental factors play little role in determining the disease severity.
Resumo:
A miniaturized flow-through system consisting of a gold coated silicon substrate based on enhanced Raman spectroscopy has been used to study the detection of vapour from model explosive compounds. The measurements show that the detectability of the vapour molecules at room temperature depends sensitively on the interaction between the molecule and the substrate. The results highlight the capability of a flow system combined with Raman spectroscopy for detecting low vapour pressure compounds with a limit of detection of 0.2 ppb as demonstrated by the detection of bis(2-ethylhexyl)phthalate, a common polymer additive emitted from a commercial polyvinyl chloride (PVC) tubing at room temperature.
Resumo:
The self-assembly of layered molybdenum disulfide–graphene (MoS2–Gr) and horseradish peroxidase (HRP) by electrostatic attraction into a novel hybrid nanomaterial (HRP–MoS2–Gr) is reported. The properties of the MoS2–Gr were characterized by X-ray diffraction (XRD), high-resolution transmission electron microscopy (TEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). UV–vis and Fourier transform infrared spectroscopy (FT-IR) indicate that the native structure of the HRP is maintained after the assembly, implying good biocompatibility of MoS2–Gr nanocomposite. Furthermore, the HRP–MoS2–Gr composite is utilized as a biosensor, which displays electrocatalytic activity to hydrogen peroxide (H2O2) with high sensitivity (679.7 μA mM−1 cm−2), wide linear range (0.2 μM–1.103 mM), low detection limit (0.049 μM), and fast amperometric response. In addition, the biosensor also exhibits strong anti-interference ability, satisfactory stability and reproducibility. These desirable electrochemical properties are attributed to the good biocompatibility and electron transport efficiency of the MoS2–Gr composite, as well as the high loading of HRP. Therefore, this biosensor is potentially suitable for H2O2 analysis in environmental, pharmaceutical, food or industrial applications.
Resumo:
BACKGROUND AND OBJECTIVE: Idiopathic pulmonary fibrosis (IPF) is a degenerative disease characterized by fibrosis following failed epithelial repair. Mesenchymal stromal cells (MSC), a key component of the stem cell niche in bone marrow and possibly other organs including lung, have been shown to enhance epithelial repair and are effective in preclinical models of inflammation-induced pulmonary fibrosis, but may be profibrotic in some circumstances. METHODS: In this single centre, non-randomized, dose escalation phase 1b trial, patients with moderately severe IPF (diffusing capacity for carbon monoxide (DLCO ) ≥ 25% and forced vital capacity (FVC) ≥ 50%) received either 1 × 10(6) (n = 4) or 2 × 10(6) (n = 4) unrelated-donor, placenta-derived MSC/kg via a peripheral vein and were followed for 6 months with lung function (FVC and DLCO ), 6-min walk distance (6MWD) and computed tomography (CT) chest. RESULTS: Eight patients (4 female, aged 63.5 (57-75) years) with median (interquartile range) FVC 60 (52.5-74.5)% and DLCO 34.5 (29.5-40)% predicted were treated. Both dose schedules were well tolerated with only minor and transient acute adverse effects. MSC infusion was associated with a transient (1% (0-2%)) fall in SaO2 after 15 min, but no changes in haemodynamics. At 6 months FVC, DLCO , 6MWD and CT fibrosis score were unchanged compared with baseline. There was no evidence of worsening fibrosis. CONCLUSIONS: Intravenous MSC administration is feasible and has a good short-term safety profile in patients with moderately severe IPF.
Resumo:
Background Multiple health behavior change can ameliorate adverse effects of cancer. Purpose The purpose of this study was to determine the effects of a multiple health behavior change intervention (CanChange) for colorectal cancer survivors on psychosocial outcomes and quality of life. Methods A total of 410 colorectal cancer survivors were randomized to a 6-month telephone-based health coaching intervention (11 sessions using acceptance and commitment therapy strategies focusing on physical activity, weight management, diet, alcohol, and smoking) or usual care. Posttraumatic growth, spirituality, acceptance, mindfulness, distress, and quality of life were assessed at baseline, 6 and 12 months. Results Significant intervention effects were observed for posttraumatic growth at 6 (7.5, p < 0.001) and 12 months (4.1, p = 0.033), spirituality at 6 months (1.8, p = 0.011), acceptance at 6 months (0.2, p = 0.005), and quality of life at 6 (0.8, p = 0.049) and 12 months (0.9, p = 0.037). Conclusions The intervention improved psychosocial outcomes and quality of life (physical well-being) at 6 months with most effects still present at 12 months. (Trial Registration Number: ACTRN12608000399392).
Resumo:
Purpose The purpose of this investigation was to assess the angular dependence of a commercial optically stimulated luminescence dosimeter (OSLD) dosimetry system in MV x-ray beams at depths beyondd max and to find ways to mitigate this dependence for measurements in phantoms. Methods Two special holders were designed which allow a dosimeter to be rotated around the center of its sensitive volume. The dosimeter's sensitive volume is a disk, 5 mm in diameter and 0.2 mm thick. The first holder rotates the disk in the traditional way. It positions the disk perpendicular to the beam (gantry pointing to the floor) in the initial position (0°). When the holder is rotated the angle of the disk towards the beam increases until the disk is parallel with the beam (“edge on,” 90°). This is referred to as Setup 1. The second holder offers a new, alternative measurement position. It positions the disk parallel to the beam for all angles while rotating around its center (Setup 2). Measurements with five to ten dosimeters per point were carried out for 6 MV at 3 and 10 cm depth. Monte Carlo simulations using GEANT4 were performed to simulate the response of the active detector material for several angles. Detector and housing were simulated in detail based on microCT data and communications with the manufacturer. Various material compositions and an all-water geometry were considered. Results For the traditional Setup 1 the response of the OSLD dropped on average by 1.4% ± 0.7% (measurement) and 2.1% ± 0.3% (Monte Carlo simulation) for the 90° orientation compared to 0°. Monte Carlo simulations also showed a strong dependence of the effect on the composition of the sensitive layer. Assuming the layer to completely consist of the active material (Al2O3) results in a 7% drop in response for 90° compared to 0°. Assuming the layer to be completely water, results in a flat response within the simulation uncertainty of about 1%. For the new Setup 2, measurements and Monte Carlo simulations found the angular dependence of the dosimeter to be below 1% and within the measurement uncertainty. Conclusions The dosimeter system exhibits a small angular dependence of approximately 2% which needs to be considered for measurements involving other than normal incident beams angles. This applies in particular to clinicalin vivo measurements where the orientation of the dosimeter is dictated by clinical circumstances and cannot be optimized as otherwise suggested here. When measuring in a phantom, the proposed new setup should be considered. It changes the orientation of the dosimeter so that a coplanar beam arrangement always hits the disk shaped detector material from the thin side and thereby reduces the angular dependence of the response to within the measurement uncertainty of about 1%. This improvement makes the dosimeter more attractive for clinical measurements with multiple coplanar beams in phantoms, as the overall measurement uncertainty is reduced. Similarly, phantom based postal audits can transition from the traditional TLD to the more accurate and convenient OSLD.
Resumo:
A set of packed micro paddy lysimeters, placed in a greenhouse, was used to simulate the dissipation of two herbicides, simetryn and thiobencarb, in a controlled environment. Data from a field monitoring study in 2003, including the soil condition and water balances, were used in the simulation. The herbicides were applied and monitored over a period of 21 d. The water balances under two water management scenarios, intermittent irrigation management (AI) and continuous irrigation management (CI), were simulated. In the AI scenario, the pattern of herbicide dissipation in the surface water of the field were simulated, following the first-order kinetics. In the CI scenario, similarity was observed in most lysimeter and field concentrations, but there were differences in some data points. Dissipation curves of both herbicides in the surface water of the two simulated scenarios were not significantly different (P > 0.05) from the field data except for intercept of the thiobencarb curve in the CI scenario. The distribution of simetryn and thiobencarb in the soil profile after simulation were also similar to the field data. The highest concentrations of both herbicides were found on the topsoil layer at 0-2.5 cm depth. Only a small amount of herbicides moved down to the deeper soil layers. Micro paddy lysimeters are thus a good alternative for the dissipation study of pesticides in the paddy environment.
Resumo:
Genome-wide association studies (GWASs) have been successful at identifying single-nucleotide polymorphisms (SNPs) highly associated with common traits; however, a great deal of the heritable variation associated with common traits remains unaccounted for within the genome. Genome-wide complex trait analysis (GCTA) is a statistical method that applies a linear mixed model to estimate phenotypic variance of complex traits explained by genome-wide SNPs, including those not associated with the trait in a GWAS. We applied GCTA to 8 cohorts containing 7096 case and 19 455 control individuals of European ancestry in order to examine the missing heritability present in Parkinson's disease (PD). We meta-analyzed our initial results to produce robust heritability estimates for PD types across cohorts. Our results identify 27% (95% CI 17-38, P = 8.08E - 08) phenotypic variance associated with all types of PD, 15% (95% CI -0.2 to 33, P = 0.09) phenotypic variance associated with early-onset PD and 31% (95% CI 17-44, P = 1.34E - 05) phenotypic variance associated with late-onset PD. This is a substantial increase from the genetic variance identified by top GWAS hits alone (between 3 and 5%) and indicates there are substantially more risk loci to be identified. Our results suggest that although GWASs are a useful tool in identifying the most common variants associated with complex disease, a great deal of common variants of small effect remain to be discovered. © Published by Oxford University Press 2012.