136 resultados para fracture mechanics
Resumo:
The growth of a single cylindrical hole ahead of a blunt crack tip was studied using large deformation finite element analysis in three-point bend specimens with different precrack depth. The effect of small second phase particles was taken into account by incorporating Gurson’s constitutive equation. The effects of strain hardening and the initial distance from the hole to the crack tip were also investigated. The results show that the variation of crack tip opening displacement with load is not sensitive to constraint level. The effects of constraint on the growth of hole and ductile initiation toughness are diminished with decreasing initial distance from the hole to the blunt crack tip.
Resumo:
The mechanical properties of microfilament networks are systematically summarized at different special scales in this paper. We have presented the mechanical models of single microfilaments and microfilament networks at microscale. By adopting a coarse-grained simulation strategy, the mechanical stability of microfilaments related cellular structures are analysed. Structural analysis is conducted to microfilament networks to understand the stress relaxation under compression. The nanoscale molecular mechanisms of the microfilaments deformation is also summarized from the viewpoint of molecular dynamics simulation. This paper provides the fundaments of multiscale modelling framework for the mechanical behaviours simulation of hierarchical microfilament networks.
Resumo:
The effects of acid treatment, vapor grown carbon fiber (VGCF) interlayer and the angle, i.e., 0° and 90°, between the rolling stripes of an aluminum (Al) plate and the fiber direction of glass fiber reinforced plastics (GFRP) on the mode II interlaminar mechanical properties of GFRP/Al laminates were investigated. The experimental results of an end notched flexure test demonstrate that the acid treatment and the proper addition of VGCF can effectively improve the critical load and mode II fracture toughness of GFRP/Al laminates. The specimens with acid treatment and 10 g m−2 VGCF addition possess the highest mode II fracture toughness, i.e., 269% and 385% increases in the 0° and 90° specimens, respectively compared to those corresponding pristine ones. Due to the induced anisotropy by the rolling stripes on the aluminum plate, the 90° specimens possess 15.3%–73.6% higher mode II fracture toughness compared to the 0° specimens. The improvement mechanisms were explored by the observation of crack propagation path and fracture surface with optical, laser scanning and scanning electron microscopies. Moreover, finite element analyses were carried out based on the cohesive zone model to verify the experimental fracture toughness and to predict the interface shear strength between the aluminum plates and GFRP laminates.
Resumo:
Introduction: In an attempt to reduce stress shielding in the proximal femur multiple new shorter stem design have become available. We investigated the load to fracture of a new polished tapered cemented short stem in comparison to the conventional polished tapered Exeter stem. Method: A total of forty-two stems, twenty-one short stems and twenty-one conventional stems both with three different offsets were cemented in a composite sawbone model and loaded to fracture. Results: study showed that femurs will break at a significantly lower load to failure with a shorter compared to conventional length Exeter stem. Conclusion: This Both standard and short stem design are safe to use as the torque to failure is 7–10 times as much as the torques seen in activities of daily living.
Resumo:
This project examined the differences in healing of metaphyseal bone, when the implants of variable stiffness are used for fracture fixation. This knowledge is important in development of novel orthopaedic implants, used in orthopaedic surgery to stabilise the fractures. Dr Koval used a mouse model to create a fracture, and then assessed its healing with a combination of mechanical testing, microcomputed tomography and histomorphometric examination.
Resumo:
Complex bone contour and anatomical variations between individual bones complicate the process of deriving an implant shape that fits majority of the population. This thesis proposes an automatic fitting method for anatomically-precontoured plates based on clinical requirements, and investigated if 100% anatomical fit for a group of bone is achievable through manual bending of one plate shape. It was found that, for the plate used, 100% fit is impossible to achieve through manual bending alone. Rather, newly-developed shapes are also required to obtain anatomical fit in areas with more complex bone contour.
Resumo:
Study Design Delphi panel and cohort study. Objective To develop and refine a condition-specific, patient-reported outcome measure, the Ankle Fracture Outcome of Rehabilitation Measure (A-FORM), and to examine its psychometric properties, including factor structure, reliability, and validity, by assessing item fit with the Rasch model. Background To our knowledge, there is no patient-reported outcome measure specific to ankle fracture with a robust content foundation. Methods A 2-stage research design was implemented. First, a Delphi panel that included patients and health professionals developed the items and refined the item wording. Second, a cohort study (n = 45) with 2 assessment points was conducted to permit preliminary maximum-likelihood exploratory factor analysis and Rasch analysis. Results The Delphi panel reached consensus on 53 potential items that were carried forward to the cohort phase. From the 2 time points, 81 questionnaires were completed and analyzed; 38 potential items were eliminated on account of greater than 10% missing data, factor loadings, and uniqueness. The 15 unidimensional items retained in the scale demonstrated appropriate person and item reliability after (and before) removal of 1 item (anxious about footwear) that had a higher-than-ideal outfit statistic (1.75). The “anxious about footwear” item was retained in the instrument, but only the 14 items with acceptable infit and outfit statistics (range, 0.5–1.5) were included in the summary score. Conclusion This investigation developed and refined the A-FORM (Version 1.0). The A-FORM items demonstrated favorable psychometric properties and are suitable for conversion to a single summary score. Further studies utilizing the A-FORM instrument are warranted. J Orthop Sports Phys Ther 2014;44(7):488–499. Epub 22 May 2014. doi:10.2519/jospt.2014.4980
Resumo:
Graphyne is an allotrope of graphene. The mechanical properties of graphynes (α-, β-, γ- and 6,6,12-graphynes) under uniaxial tension deformation at different temperatures and strain rates are studied using molecular dynamics simulations. It is found that graphynes are more sensitive to temperature changes than graphene in terms of fracture strength and Young's modulus. The temperature sensitivity of the different graphynes is proportionally related to the percentage of acetylenic linkages in their structures, with the α-graphyne (having 100% of acetylenic linkages) being most sensitive to temperature. For the same graphyne, temperature exerts a more pronounced effect on the Young's modulus than fracture strength, which is different from that of graphene. The mechanical properties of graphynes are also sensitive to strain rate, in particular at higher temperatures.
Resumo:
This paper proposes a physically motivated reappraisal of manoeuvring models for ships and presents a new model developed from first principles by application of low aspect-ratio aerodynamic theory and Lagrangian mechanics. The coefficients of the model are shown to be related to physical processes, and validation is presented using the results from a planar motion mechanism dataset.
Resumo:
During fracture healing, many complex and cryptic interactions occur between cells and bio-chemical molecules to bring about repair of damaged bone. In this thesis two mathematical models were developed, concerning the cellular differentiation of osteoblasts (bone forming cells) and the mineralisation of new bone tissue, allowing new insights into these processes. These models were mathematically analysed and simulated numerically, yielding results consistent with experimental data and highlighting the underlying pattern formation structure in these aspects of fracture healing.
Resumo:
So far in this book, we have seen a large number of methods for generating content for existing games. So, if you have a game already, you could now generate many things for it: maps, levels, terrain, vegetation, weapons, dungeons, racing tracks. But what if you don’t already have a game, and want to generate the game itself? What would you generate, and how? At the heart of any game are its rules. This chapter will discuss representations for game rules of different kinds, along with methods to generate them, and evaluation functions and constraints that help us judge complete games rather than just isolated content artefacts. Our main focus here will be on methods for generating interesting, fun, and/or balanced game rules. However, an important perspective that will permeate the chapter is that game rule encodings and evaluation functions can encode game design expertise and style, and thus help us understand game design. By formalising aspects of the game rules, we define a space of possible rules more precisely than could be done through writing about rules in qualitative terms; and by choosing which aspects of the rules to formalise, we define what aspects of the game are interesting to explore and introduce variation in. In this way, each game generator can be thought of an executable micro-theory of game design, though often a simplified, and sometimes even a caricatured one
Resumo:
Anatomically pre-contoured fracture fixation plates are a treatment option for bone fractures. A well-fitting plate can be used as a tool for anatomical reduction of the fractured bone. However, recent studies showed that some plates fit poorly for many patients due to considerable shape variations between bones of the same anatomical site. Therefore, the plates have to be manually fitted and deformed by surgeons to fit each patient optimally. The process is time-intensive and labor-intensive, and could lead to adverse clinical implications such as wound infection or plate failure. This paper proposes a new iterative method to simulate the patient-specific deformation of an optimally fitting plate for pre-operative planning purposes. We further demonstrate the validation of the method through a case study. The proposed method involves the integration of four commercially available software tools, Matlab, Rapidform2006, SolidWorks, and ANSYS, each performing specific tasks to obtain a plate shape that fits optimally for an individual tibia and is mechanically safe. A typical challenge when crossing multiple platforms is to ensure correct data transfer. We present an example of the implementation of the proposed method to demonstrate successful data transfer between the four platforms and the feasibility of the method.
Resumo:
PURPOSE To review records of 330 patients who underwent surgery for femoral neck fractures with or without preoperative anticoagulation therapy. METHODS Medical records of 235 women and 95 men aged 48 to 103 years (mean, 81.6; standard deviation [SD], 13.1) who underwent surgery for femoral neck fractures with or without preoperative anticoagulation therapy were reviewed. 30 patients were on warfarin, 105 on aspirin, 28 on clopidogrel, and 167 were controls. The latter 3 groups were combined as the non-warfarin group and compared with the warfarin group. Hospital mortality, time from admission to surgery, length of hospital stay, return to theatre, and postoperative complications (wound infection, deep vein thrombosis, and pulmonary embolism) were assessed. RESULTS The warfarin and control groups were significantly younger than the clopidogrel and aspirin groups (80.8 vs. 80.0 vs. 84.2 vs. 83.7 years, respectively, p<0.05). 81% of the patients underwent surgery within 48 hours of admission. The overall mean time from admission to surgery was 1.8 days; it was longer in the warfarin than the aspirin, clopidogrel, and control groups (3.3 vs. 1.8 vs. 1.6 vs. 1.6 days, respectively, p<0.001). The mean length of hospital stay was 17.5 (SD, 9.6; range, 3-54) days. The overall hospital mortality was 3.9%; it was 6.7% in the warfarin group, 3.8% in the aspirin group, 3.6% in the clopidogrel group, and 3.6% in the control group (p=0.80). Four patients returned to theatre for surgery: one in the warfarin group for washout of a haematoma, 2 in the aspirin group for repositioning of a mal-fixation and for debridement of wound infection, and one in the control group for debridement of wound infection. The warfarin group did not differ significantly from non-warfarin group in terms of postoperative complication rate (6.7% vs. 2.7%, p=0.228) and the rate of return to theatre (3.3% vs. 1%, p=0.318). CONCLUSION It is safe to continue aspirin and clopidogrel prior to surgical treatment for femoral neck fracture. The risk of delaying surgery outweighs the peri-operative bleeding risk.
Resumo:
By taking the advantage of the excellent mechanical properties and high specific surface area of graphene oxide (GO) sheets, we develop a simple and effective strategy to improve the interlaminar mechanical properties of carbon fiber reinforced plastic (CFRP) laminates. With the incorporation of graphene oxide reinforced epoxy interleaf into the interface of CFRP laminates, the Mode-I fracture toughness and resistance were greatly increased. The experimental results of double cantilever beam (DCB) tests demonstrated that, with 2 g/m2 addition of GO, the Mode-I fracture toughness and resistance of the specimen increase by 170.8% and 108.0%, respectively, compared to those of the plain specimen. The improvement mechanisms were investigated by the observation of fracture surface with scanning electron microscopies. Moreover, finite element analyses were performed based on the cohesive zone model to verify the experimental fracture toughness and to predict the interfacial tensile strength of CFRP laminates.