115 resultados para Static balance
Resumo:
Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.
Resumo:
Purpose To test the effectiveness of static and dynamic orthoses using them as an exclusive treatment for proximal interphalangeal (PIP) joint flexion contracture compared with other hand therapy conservative treatments described in the literature. Methods 60 patients who used orthoses were compared with a control group that received other hand therapy treatments. Clinical assessments were measured before the experiment and 3 months after and included active PIP joint extension and function. Results A significant improvement in the extension active range of motion at the PIP joint in the second measurement was found in both groups, but it was significantly greater in the experimental group. Improvement in function (Disabilities of the Arm, Shoulder, and Hand score) between the first and second assessment was similar in the control and experimental groups. Conclusions Using night progressive static and daily dynamic orthoses as an exclusive treatment during the proliferative phase led to significant improvements in the PIP joint active extension, but the improvement did not correlate with increased function as perceived by the patient.
Resumo:
This lively book, Reclaiming Fair Use: How to Put Balance Back in Copyright, is designed to liberate people from the "Mind Forg'd Manacles" of copyright law. The authors - film and media scholar Patricia Aufderheide and professor of law and stalwart defender of the public interest Peter Jaszi - hope to help readers "understand how to think about and use copyright, and especially your right to use copyrighted material without permission or payment when you make a work - whether a blog entry, a song, a mashup, a poem, a documentary, a magazine article, a lesson plan, a scholarly archive, a slide show, a technical manual, a scrapbook, a collage, or a brochure"...
Resumo:
Groundwater modelling studies rely on an accurate determination of inputs and outputs that make up the water balance. Often there is large uncertainty associated with estimates of recharge and unmetered groundwater use. This can translate to equivalent uncertainty in the forecasting of sustainable yields, impacts of extraction, and susceptibility of groundwater dependent ecosystems. In the case of Coal Seam Gas, it is important to characterise the temporal and special distribution of depressurisation in the reservoir and how this may or may not extend to the adjacent aquifers. A regional groundwater flow model has been developed by the Queensland Government to predict drawdown impacts due to Coal Seam Gas activities in the Surat basin. This groundwater model is undergoing continued refinement and there is currently scope to address some of the key areas of uncertainty including better quantification of groundwater recharge and unmetered groundwater extractions. Research is currently underway to improve the accuracy of estimates of both of these components of the groundwater balance in order to reduce uncertainty in predicted groundwater drawdowns due to CSG activities.
Resumo:
Experiential value is an important driver of customer repeat behaviour and is necessary for achieving sustained behaviour. Understanding the value gained by consumers is particularly important when adopting innovative techniques, such as new technology. Social marketing (behaviour change) practice is increasingly using the technology of mobile games (m-games), yet there is little scholarly research to explain how these games can create experiential value for the user, or which game attributes influence this value. A key finding of this thesis is the importance of achieving a balance between entertainment value and behaviour value through the use of key game attributes relating to disguise and performance. The research offers a contribution to address current managerial problems faced by social marketing practitioners looking to employ m-games to achieve behavioural outcomes.
Resumo:
Background To date bone-anchored prostheses are used to alleviate the concerns caused by socket suspended prostheses and to improve the quality of life of transfemoral amputees (TFA). Currently, two implants are commercially available (i.e., OPRA (Integrum AB, Sweden), ILP (Orthodynamics GmbH, Germany)). [1-17]The success of the OPRA technique is codetermined by the rehabilitation program. TFA fitted with an osseointegrated implant perform progressive mechanical loading (i.e. static load bearing exercises (LBE)) to facilitate bone remodelling around the implant.[18, 19] Aim This study investigated the trustworthiness of monitoring the load prescribed (LP) during experimental static LBEs using the vertical force provided by a mechanical bathroom scale that is considered a surrogate of the actual load applied. Method Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. The “axial” and “vectorial” comparisons corresponding to the difference between the force applied on the long axis of the fixation and LP as well as the resultant of the three components of the load applied and LP, respectively were analysed Results For each loading condition, Wilcoxon One-Sample Signed Rank Tests were used to investigate if significant differences (p<0.05) could be demonstrated between the force applied on the long axis and LP, and between the resultant of the force and LP. The results demonstrated that the raw axial and vectorial differences were significantly different from zero in all conditions (p<0.05), except for the vectorial difference for the 40 kg loading condition (p=0.182). The raw axial difference was negative for all the participants in every loading condition, except for TFA03 in the 10 kg condition (11.17 N). Discussion & Conclusion This study showed a significant lack of axial compliance. The load applied on the long axis was significantly smaller than LP in every loading condition. This led to a systematic underloading of the long axis of the implant during the proposed experimental LBE. Monitoring the vertical force might be only partially reflective of the actual load applied, particularly on the long axis of the implant.
Resumo:
Section 54 of the Insurance Contracts Act 1984 (Cth) continues to occupy a prominent position in insurance-related litigation. This section which imposes a concept of causation, or prejudice to the insurer, to restrict an insurer’s reliance upon contractual terms to avoid liability for particular claims, is often before the courts. This note focuses upon the recent High Court of Australia decision in Maxwell v Highway Hauliers Pty Ltd [2014] HCA 33.
Resumo:
This article canvasses recent case law adjudicating the uneasy disclosure balance between the interests of the insurer and the insured in the process of transacting an insurance contract. It examines also the consequences of non-disclosure and misrepresentation and whether the avowed legislative intent — that the liability of the insurer in respect of a claim is to be reduced to the amount that would place the insurer in the position it would have been had the non-disclosure or misrepresentation not occurred — is being achieved in practice. As there is no doubt as to who bears the onus of proof as to non-disclosure or misrepresentation it is surprising that insurers continue to flounder in this regard in relation to underwriting guidelines and adherence to them. The article reviews recent case law in this context and stresses that an insurer wishing to preserve its capacity to avoid liability on the basis that it would not have entered into a contract at all had the true situation been known to it must maintain detailed underwriting guidelines supported by consistent adherence to those guidelines. Recent case law also emphasises that the insurer must provide clear and cogent admissible evidence from appropriate personnel and officers of the company to discharge its onus.
Resumo:
Aurizon, Australia's largest rail freight operator, is introducing the Static Frequency Converter (SFC) technology into its electric railway network as part of the Bauhinia Electrification Project. The introduction of SFCs has significant implications on the protection systems of the 50kV traction network. The traditional distance protection calculation method does not work in this configuration because of the effect that the SFC in combination with the remote grid has on the apparent impedance, and was substantially reviewed. The standard overcurrent (OC) protection scheme is not suitable due to the minimum fault level being below the maximum load level and was revised to incorporate directionality and under-voltage inhibit. Delta protection was reviewed to improve sensitivity. A new protection function was introduced to prevent back-feeding faults in the transmission network through the grid connection. Protection inter-tripping was included to ensure selectivity between the SFC protection and the system downstream.
Resumo:
Aurizon, Australia's largest freight railway operator, is investigating the use of Rail Power Conditioner (RPC) technology for load balancing, reactive power compensation and harmonic filtering. The new technology has the capability of replacing Static VAr Compensators (SVC) and Harmonic Filters, and is expected to have a significant impact on the overall costs of railway electrification. This paper presents the theoretical analysis of the real and reactive power flows in an RPC used to balance active powers in an existing V/V feeder station. This informed an RPC feasibility study undertaken at four existing Aurizon's feeder stations with V/V connected transformers.