186 resultados para Relative intensity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper examines the dynamic behaviour of relative prices across seven Australian cities by applying panel unit root test procedures with structural breaks to quarterly consumer price index data for 1972 Q1–2011 Q4. We find overwhelming evidence of convergence in city relative prices. Three common structural breaks are endogenously determined at 1985, 1995, and 2007. Further, correcting for two potential biases, namely Nickell bias and time aggregation bias, we obtain half-life estimates of 2.3–3.8 quarters that are much shorter than those reported by previous research. Thus, we conclude that both structural breaks and bias corrections are important to obtain shorter half-life estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Machine vision is emerging as a viable sensing approach for mid-air collision avoidance (particularly for small to medium aircraft such as unmanned aerial vehicles). In this paper, using relative entropy rate concepts, we propose and investigate a new change detection approach that uses hidden Markov model filters to sequentially detect aircraft manoeuvres from morphologically processed image sequences. Experiments using simulated and airborne image sequences illustrate the performance of our proposed algorithm in comparison to other sequential change detection approaches applied to this application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose The goal of this work was to set out a methodology for measuring and reporting small field relative output and to assess the application of published correction factors across a population of linear accelerators. Methods and materials Measurements were made at 6 MV on five Varian iX accelerators using two PTW T60017 unshielded diodes. Relative output readings and profile measurements were made for nominal square field sizes of side 0.5 to 1.0 cm. The actual in-plane (A) and cross-plane (B) field widths were taken to be the FWHM at the 50% isodose level. An effective field size, defined as FSeff=A·B, was calculated and is presented as a field size metric. FSeffFSeff was used to linearly interpolate between published Monte Carlo (MC) calculated kQclin,Qmsrfclin,fmsr values to correct for the diode over-response in small fields. Results The relative output data reported as a function of the nominal field size were different across the accelerator population by up to nearly 10%. However, using the effective field size for reporting showed that the actual output ratios were consistent across the accelerator population to within the experimental uncertainty of ±1.0%. Correcting the measured relative output using kQclin,Qmsrfclin,fmsr at both the nominal and effective field sizes produce output factors that were not identical but differ by much less than the reported experimental and/or MC statistical uncertainties. Conclusions In general, the proposed methodology removes much of the ambiguity in reporting and interpreting small field dosimetric quantities and facilitates a clear dosimetric comparison across a population of linacs

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports and discusses a contentious result from an Australia-wide study of the influences on students' decisions about taking senior science subjects. As part of the Choosing Science study (Lyons and Quinn 2010) 3759 Year 10 students were asked to indicate which stage of their schooling (lower primary, upper primary, lower secondary, middle secondary) they had most enjoyed learning science. Crosstabulations of responses revealed that around 78% of students indicated that they had enjoyed learning science more in secondary than in primary school, and 55% enjoyed it the most during Years 9 and 10. The perception that school science was more enjoyable in high school was also found among students who did not intend taking science in Year 11, though to a lesser extent. These findings are unexpected and significant, challenging the prevailing view that enjoyment of school science steadily declines after primary school. The paper elaborates on the findings and suggests that the different conclusions arrived at by studies in this field may be due to the different methodologies employed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Executive Summary Emergency Departments (EDs) locally, nationally and internationally are becoming increasingly busy. Within this context, it can be challenging to deliver a health service that is safe, of high quality and cost-effective. Whilst various models are described within the literature that aim to measure ED ‘work’ or ‘activity’, they are often not linked to a measure of costs to provide such activity. It is important for hospital and ED managers to understand and apply this link so that optimal staffing and financial resourcing can be justifiably sought. This research is timely given that Australia has moved towards a national Activity Based Funding (ABF) model for ED activity. ABF is believed to increase transparency of care and fairness (i.e. equal work receives equal pay). ABF involves a person-, performance- or activity-based payment system, and thus a move away from historical “block payment” models that do not incentivise efficiency and quality. The aim of the Statewide Workforce and Activity-Based Funding Modelling Project in Queensland Emergency Departments (SWAMPED) is to identify and describe best practice Emergency Department (ED) workforce models within the current context of ED funding that operates under an ABF model. The study is comprised of five distinct phases. This monograph (Phase 1) comprises a systematic review of the literature that was completed in June 2013. The remaining phases include a detailed survey of Queensland hospital EDs’ resource levels, activity and operational models of care, development of new resource models, development of a user-friendly modelling interface for ED mangers, and production of a final report that identifies policy implications. The anticipated deliverable outcome of this research is the development of an ABF based Emergency Workforce Modelling Tool that will enable ED managers to profile both their workforce and operational models of care. Additionally, the tool will assist with the ability to more accurately inform adequate staffing numbers required in the future, inform planning of expected expenditures and be used for standardisation and benchmarking across similar EDs. Summary of the Findings Within the remit of this review of the literature, the main findings include: 1. EDs are becoming busier and more congested Rising demand, barriers to ED throughput and transitions of care all contribute to ED congestion. In addition requests by organisational managers and the community require continued broadening of the scope of services required of the ED and further increases in demand. As the population live longer with more lifestyle diseases their propensity to require ED care continues to grow. 2. Various models of care within EDs exist Models often vary to account for site specific characteritics to suit staffing profile, ED geographical location (e.g. metropolitan or rural site), and patient demographic profile (e.g. paediatrics, older persons, ethnicity). Existing and new models implemented within EDs often depend on the target outcome requiring change. Generally this is focussed on addressing issues at the input, throughput or output areas of the ED. Even with models targeting similar demographic or illness, the structure and process elements underpinning the model can vary, which can impact on outcomes and variance to the patient and carer experience between and within EDs. Major models of care to manage throughput inefficiencies include: A. Workforce Models of Care focus on the appropriate level of staffing for a given workload to provide prompt, timely and clinically effective patient care within an emergency care setting. The studies reviewed suggest that the early involvement of senior medical decision maker and/or specialised nursing roles such as Emergency Nurse Practitioners and Clinical Initiatives Nurse, primary contact or extended scope Allied Health Practitioners can facilitate patient flow and improve key indicators such as length of stay and reducing the number of those who did not wait to be seen amongst others. B. Operational Models of Care within EDs focus on mechanisms for streaming (e.g. fast-tracking) or otherwise grouping patient care based on acuity and complexity to assist with minimising any throughput inefficiencies. While studies support the positive impact of these models in general, it appears that they are most effective when they are adequately resourced. 3. Various methods of measuring ED activity exist Measuring ED activity requires careful consideration of models of care and staffing profile. Measuring activity requires the ability to account for factors including: patient census, acuity, LOS, intensity of intervention, department skill-mix plus an adjustment for non-patient care time. 4. Gaps in the literature Continued ED growth calls for new and innovative care delivery models that are safe, clinically effective and cost effective. New roles and stand-alone service delivery models are often evaluated in isolation without considering the global and economic impact on staffing profiles. Whilst various models of accounting for and measuring health care activity exist, costing studies and cost effectiveness studies are lacking for EDs making accurate and reliable assessments of care models difficult. There is a necessity to further understand, refine and account for measures of ED complexity that define a workload upon which resources and appropriate staffing determinations can be made into the future. There is also a need for continued monitoring and comprehensive evaluation of newly implemented workforce modelling tools. This research acknowledges those gaps and aims to: • Undertake a comprehensive and integrated whole of department workforce profiling exercise relative to resources in the context of ABF. • Inform workforce requirements based on traditional quantitative markers (e.g. volume and acuity) combined with qualitative elements of ED models of care; • Develop a comprehensive and validated workforce calculation tool that can be used to better inform or at least guide workforce requirements in a more transparent manner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across 5 centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity-modulated radiotherapy (IMRT) and 47 treated with volumetric-modulated arc therapy (VMAT). Methods Treatment plan quality was evaluated in terms of target dose homogeneity and organ-at-risk sparing, through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each organ-at-risk. Statistical significance was evaluated using two-tailed Welch’s T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. Results The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the organs-at-risk: with increased compliance with recommended organ-at-risk dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. Conclusions This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since World War I, explosions have accounted for over 70% of all injuries in conflict. With the development of improved personnel protection of the torso, improved medical care and faster aeromedical evacuation, casualties are surviving with more severe injuries to the extremities. Understanding the processes involved in the transfer of blast-induced shock waves through biological tissues is essential for supporting efforts aimed at mitigating and treating blast injury. Given the inherent heterogeneities in the human body, we argue that studying these processes demands a highly integrated approach requiring expertise in shock physics, biomechanics and fundamental biological processes. This multidisciplinary systems approach enables one to develop the experimental framework for investigating the material properties of human tissues that are subjected to high compression waves in blast conditions and the fundamental cellular processes altered by this type of stimuli. Ultimately, we hope to use the information gained from these studies in translational research aimed at developing improved protection for those at risk and improved clinical outcomes for those who have been injured from a blast wave.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have determined the effect of two exercise-training intensities on the phospholipid profile of both glycolytic and oxidative muscle fibers of female Sprague-Dawley rats using electrospray-ionization mass spectrometry. Animals were randomly divided into three training groups: control, which performed no exercise training; low-intensity (8 m/min) treadmill running; or high-intensity (28 m/min) treadmill running. All exercise-trained rats ran 1,000 m/session for 4 days/wk for 4 wk and were killed 48 h after the last training bout. Exercise training was found to produce no novel phospholipid species but was associated with significant alterations in the relative abundance of a number of phospholipid molecular species. These changes were more prominent in glycolytic (white vastus lateralis) than in oxidative (red vastus lateralis) muscle fibers. The largest observed change was a decrease of ∼20% in the abundance of 1-stearoyl-2-docosahexaenoyl-phosphatidylethanolamine [PE(18:0/22:6); P < 0.001] ions in both the low- and high-intensity training regimes in glycolytic fibers. Increases in the abundance of 1-oleoyl-2-linoleoyl phopshatidic acid [PA(18:1/18:2); P < 0.001] and 1-alkenylpalmitoyl-2-linoleoyl phosphatidylethanolamine [plasmenyl PE (16:0/18:2); P < 0.005] ions were also observed for both training regimes in glycolytic fibers. We conclude that exercise training results in a remodeling of phospholipids in rat skeletal muscle. Even though little is known about the physiological or pathophysiological role of specific phospholipid molecular species in skeletal muscle, it is likely that this remodeling will have an impact on a range of cellular functions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To compare the classification accuracy of previously published RT3 accelerometer cut-points for youth using energy expenditure, measured via portable indirect calorimetry, as a criterion measure. DESIGN: Cross-sectional cross-validation study. METHODS: 100 children (mean age 11.2±2.8 years, 61% male) completed 12 standardized activities trials (3 sedentary, 5 lifestyle and 4 ambulatory) while wearing an RT3 accelerometer. V˙O2 was measured concurrently using the Oxycon Mobile portable calorimeter. Cut-points by Vanhelst (VH), Rowlands (RW), Chu (CH), Kavouras (KV) and the RT3 manufacturer (RT3M) were used to classify PA intensity as sedentary (SED), light (LPA), moderate (MPA) or vigorous (VPA). Classification accuracy was evaluated using the area under the Receiver Operating Characteristic curve (ROC-AUC) and weighted Kappa (κ). RESULTS: For moderate-to-vigorous PA (MVPA), VH, KV and RW exhibited excellent accuracy classification (ROC-AUC≥0.90), while the CH and RT3M exhibited good classification accuracy (ROC-AUC>0.80). Classification accuracy for LPA was fair to poor (ROC-AUC<0.76). For SED, VH exhibited excellent classification accuracy (ROC-AUC>0.90), while RW, CH, and RT3M exhibited good classification accuracy (ROC-AUC>0.80). Kappa statistics ranged from 0.67 (VH) to 0.55 (CH). CONCLUSIONS: All cut-points provided acceptable classification accuracy for SED and MVPA, but limited accuracy for LPA. On the basis of classification accuracy over all four levels of intensity, the use of the VH cut-points is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The absence of comparative validity studies has prevented researchers from reaching consensus regarding the application of intensity-related accelerometer cut points for children and adolescents. PURPOSE This study aimed to evaluate the classification accuracy of five sets of independently developed ActiGraph cut points using energy expenditure, measured by indirect calorimetry, as a criterion reference standard. METHODS A total of 206 participants between the ages of 5 and 15 yr completed 12 standardized activity trials. Trials consisted of sedentary activities (lying down, writing, computer game), lifestyle activities (sweeping, laundry, throw and catch, aerobics, basketball), and ambulatory activities (comfortable walk, brisk walk, brisk treadmill walk, running). During each trial, participants wore an ActiGraph GT1M, and VO 2 was measured breath-by-breath using the Oxycon Mobile portable metabolic system. Physical activity intensity was estimated using five independently developed cut points: Freedson/Trost (FT), Puyau (PU), Treuth (TR), Mattocks (MT), and Evenson (EV). Classification accuracy was evaluated via weighted κ statistics and area under the receiver operating characteristic curve (ROC-AUC). RESULTS Across all four intensity levels, the EV (κ = 0.68) and FT (κ = 0.66) cut points exhibited significantly better agreement than TR (κ = 0.62), MT (κ = 0.54), and PU (κ = 0.36). The EV and FT cut points exhibited significantly better classification accuracy for moderate-to vigorous-intensity physical activity (ROC-AUC = 0.90) than TR, PU, or MT cut points (ROC-AUC = 0.77-0.85). Only the EV cut points provided acceptable classification accuracy for all four levels of physical activity intensity and performed well among children of all ages. The widely applied sedentary cut point of 100 counts per minute exhibited excellent classification accuracy (ROC-AUC = 0.90). CONCLUSIONS On the basis of these findings, we recommend that researchers use the EV ActiGraph cut points to estimate time spent in sedentary, light-, moderate-, and vigorous-intensity activity in children and adolescents. Copyright © 2011 by the American College of Sports Medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To explore the feasibility of conducting a 10-week home-based physical activity (PA) programme and evaluate the changes in insulin sensitivity (S I) commensurate with the programme in obese young people. Design Open-labelled intervention. Setting Home-based intervention with clinical assessments at a tertiary paediatric hospital. Subjects 18 obese (body mass index (BMI)>International Obesity Task Force age and sex-specifi c cut-offs) children and adolescents (8-18 years, 11 girls/7 boys) were recruited. 15 participants (nine girls/six boys, mean±SE age 11.8±0.6 years, BMI-SD scores (BMI-SDS) 3.5±0.1, six prepubertal/nine pubertal) completed the intervention. Intervention The programme comprised biweekly home visits over 10 weeks with personalised plans implemented aiming to increase moderate-intensity PA. Pedometers and PA diaries were used as self-monitoring tools. The goals were to (1) teach participants behavioural skills related to adopting and maintaining an active lifestyle and (2) increase daily participation in PA. Outcome measures Mean steps/day were assessed. SI assessed by the frequently sampled intravenous glucose tolerance test and other components of the insulin resistance syndrome were measured. Results Mean steps/day increased significantly from 10 363±927 (baseline) to 13 013±1131 (week 10) (p<0.05). S I was also significantly increased, despite no change in BMI-SDS, and remained so after an additional 10-week follow-up. Conclusions The results suggest that such a homebased PA programme is feasible. S I improved without changes in BMI-SDS. More rigorous evaluations of such programmes are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precise clock synchronization is essential in emerging time-critical distributed control systems operating over computer networks where the clock synchronization requirements are mostly focused on relative clock synchronization and high synchronization precision. Existing clock synchronization techniques such as the Network Time Protocol (NTP) and the IEEE 1588 standard can be difficult to apply to such systems because of the highly precise hardware clocks required, due to network congestion caused by a high frequency of synchronization message transmissions, and high overheads. In response, we present a Time Stamp Counter based precise Relative Clock Synchronization Protocol (TSC-RCSP) for distributed control applications operating over local-area networks (LANs). In our protocol a software clock based on the TSC register, counting CPU cycles, is adopted in the time clients and server. TSC-based clocks offer clients a precise, stable and low-cost clock synchronization solution. Experimental results show that clock precision in the order of 10~microseconds can be achieved in small-scale LAN systems. Such clock precision is much higher than that of a processor's Time-Of-Day clock, and is easily sufficient for most distributed real-time control applications over LANs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of plasmon oscillations on the DC tunnel current in a gold nanoisland thin film (GNITF) is investigated using low intensity P~1W/cm2 continuous wave lasers. While DC voltages (1–150 V) were applied to the GNITF, it was irradiated with lasers at different wavelengths (k¼473, 532, and 633 nm). Because of plasmon oscillations, the tunnel current increased. It is found that the tunnel current enhancement is mainly due to the thermal effect of plasmon oscillations rather than other plasmonic effects. The results are highly relevant to applications of plasmonic effects in opto-electronic devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Intense exercise induced acidosis occurs from the accumulation of hydrogen ions as by-products of anaerobic metabolism. Oral ingestion of ß-alanine, a limiting precursor of the intracellular physiochemical buffer carnosine in skeletal muscle, may counteract any detrimental effect of acidosis and benefit performance. The aim of this study was to investigate the effect of ß-alanine as an ergogenic aid during high intensity exercise performance in healthy males. Methods Five males ingested either ß-alanine (BAl) (4.8 g.d-1 for 4wk, then 6.4 g.d-1 for 2wk) or placebo (Pl) (CaCO3) in a crossover design with 6 wk washout between. Following supplementation, participants performed two different intense exercise protocols over consecutive days. On the first day a repeated sprint ability (RSA) test of 5 x 6s, with 24s rest periods, was performed. On the second day a cycling capacity test measuring the time to exhaustion (TTE) was performed at 110% of their max workload achieved in a pre supplementation max test (CCT110%). Non-invasive quantification of carnosine, prior to, and following each supplementation, with magnetic resonance spectrometry was performed in the soleus and gastrocnemius. Time to fatigue (CCT110%), peak and mean power (RSA), blood pH, and plasma lactate were measured. Results Muscle carnosine concentration was not different prior to ß-alanine supplementation and increased 18% in the soleus and 26% in the gastrocnemius, respectively with 6 wk supplementation. There was no difference in the measured performance variables during the RSA test (peak and average power output). TTE during the CCT110% was significantly enhanced following the ingestion of BAl (155s ± 19.03) compared to Pl (134s ± 26.16). No changes were observed in blood pH during either exercise protocol and during the recovery from exercise. Plasma lactate in the BAl condition was significantly higher than Pl only from the 15th minute following exercise during the CCT110%. FIG. 1: Changes in carnosine concentration in the gastrocnemius prior and post 6 week chronic supplementation of placebo and β-alanine. Values expressed as mean.* p<0.05 from Pl at 6 weeks, # p<0.05 from pre supplementation. Conclusion/Discussion Greater muscle carnosine content following 6wk supplementation of ß-alanine enhanced the potential for intracellular buffering capacity. However, this only translated into enhanced performance during the CCT110% high intensity cycling exercise protocol, with no change observed during the RSA test. No differences in post exercise and recovery plasma lactates and blood pH, indicates that 6wks ß-alanine supplementation has no effect on anaerobic metabolism during multiple bout high intensity exercise. Changes in plasma lactate during recovery supports that ß-alanine supplementation may affect anaerobic metabolism however during single bout high intensity.