158 resultados para Nuclear radiation.
Resumo:
This contribution outlines Synchrotron-based X-ray micro-tomography and its potential use in structural geology and rock mechanics. The paper complements several recent reviews of X-ray microtomography. We summarize the general approach to data acquisition, post-processing as well as analysis and thereby aim to provide an entry point for the interested reader. The paper includes tables listing relevant beamlines, a list of all available imaging techniques, and available free and commercial software packages for data visualization and quantification. We highlight potential applications in a review of relevant literature including time-resolved experiments and digital rock physics. The paper concludes with a report on ongoing developments and upgrades at synchrotron facilities to frame the future possibilities for imaging sub-second processes in centimetre-sized samples.
Resumo:
The dynamics describing the motion response of a marine structure in waves can be represented within a linear framework by the Cummins Equation. This equation contains a convolution term that represents the component of the radiation forces associated with fluid memory effects. Several methods have been proposed in the literature for the identification of parametric models to approximate and replace this convolution term. This replacement can facilitate the model implementation in simulators and the analysis of motion control designs. Some of the reported identification methods consider the problem in the time domain while other methods consider the problem in the frequency domain. This paper compares the application of these identification methods. The comparison is based not only on the quality of the estimated models, but also on the ease of implementation, ease of use, and the flexibility of the identification method to incorporate prior information related to the model being identified. To illustrate the main points arising from the comparison, a particular example based on the coupled vertical motion of a modern containership vessel is presented.
Resumo:
We present a mini-scale method for nuclear run-on transcription assay. In our method, all the centrifuge steps can be carried out by using micro-tubes for short time (5 min each) throughout the process, including isolation of transcriptionally active nuclei and purification of labeled RNA after synthesis of RNA in isolated nuclei. The assay can be performed using a small amount of plant tissue, which enables analysis of developmental changes in transcriptional status of given genes in a single individual plant. Successful results were obtained using the tissues of flower and leaf of petunia and embryo of pea, suggesting that the method is potentially applicable to a variety of plant tissues.
Resumo:
The introduction of chalcone synthase A transgenes into petunia plants can result in degradation of chalcone synthase A RNAs and loss of chalcone synthase, a process called cosuppression or post-transcriptional gene silencing. Here we show that the RNA degradation is associated with changes in premRNA processing, i.e. loss of tissue specificity in transcript cleavage patterns, accumulation of unspliced molecules, and use of template-specific secondary poly(A) sites. These changes can also be observed at a lower level in leaves but not flowers of nontransgenic petunias. Based on this, a model is presented of how transgenes may disturb the carefully evolved, developmentally controlled post-transcriptional regulation of chalcone synthase gene expression by influencing the survival rate of the endogenous and their own mRNA.
Resumo:
Transcriptional gene silencing (TCS) is often associated with an increased level of cytosine methylation in the affected promoters. The effect of methylation of the cauliflower mosaic virus (CaMV) 35S promoter sequence on its binding to factors present in the nuclei was analyzed by electrophoretic mobility shift assays using extracts of petunia flowers. Specific DNA-protein interactions were detected in the region of the CaMV 35S promoter that contains the as-1 element and the region between -345 and -208. The binding of protein factor(s) to the as-1 element was influenced by cytosine methylation, whereas the binding to the region between -345 and -208 was unaffected. The results suggest that cytosine methylation of the as-1 element potentially affects the activity of the CaMV 35S promoter. © Georg Thieme Verlag KG Stuttgart.
Resumo:
This study examines the process by which newly recruited nuclear engineering and technical staff came to understand, define, think, feel and behave within a distinct group that has a direct contribution to the organization's overall emphasis on a culture of reliability and system safety. In the field of organizational behavior the interactive model of social identity formation has been recently proposed to explain the process by which the internalization of shared norms and values occurs, an element critical in identity formation. Using this rich model of organizational behavior we analyzed multiple sources of data from nine new hires over a period of three years. This was done from the time they were employed to investigate the construction of social identity by new entrants entering into a complex organizational setting reflected in the context of a nuclear facility. Informed by our data analyses, we found support for the interactive model of social identity development and report the unexpected finding that a newly appointed member's age and level of experience appears to influence the manner in which they adapt, and assimilate into their surroundings. This study represents an important contribution to the safety and reliability literature as it provides a rich insight into the way newly recruited employees enact the process by which their identities are formed and hence act, particularly under conditions of duress or significant organizational disruption in complex organizational settings.
Resumo:
The orphan nuclear receptor liver receptor homologue-1 (LRH-1) has roles in the development, cholesterol and bile acid homeostasis, and steroidogenesis. It also enhances proliferation and cell cycle progression of cancer cells. In breast cancer, LRH-1 expression is associated with invasive breast cancer; positively correlates with ERα status and aromatase activity; and promotes oestrogen-dependent cell proliferation. However, the mechanism of action of LRH-1 in breast cancer epithelial cells is still not clear. By silencing or over-expressing LRH-1 in ER-positive MCF-7 and ER-negative MDA-MB-231 breast cancer cells, we have demonstrated that LRH-1 promotes motility and cell invasiveness. Similar effects were observed in the non-tumourigenic mammary epithelial cell line, MCF-10A. Remodelling of the actin cytoskeleton and E-cadherin cleavage was observed with LRH-1 over-expression, contributing to increased migratory and invasive properties. Additionally, in LRH-1 over-expressing cells, the truncation of the 120 kDa E-cadherin to the inactive 97 kDa form was observed. These post-translational modifications in E-cadherin may be associated with LRH-1-dependent changes to matrix metalloproteinase 9 expression. These findings suggest a new role of LRH-1 in promoting migration and invasion in breast cancer, independent of oestrogen sensitivity. Therefore, LRH-1 may represent a new target for breast cancer therapeutics.
Resumo:
The effect of radiation on natural convection of Newtonian fluid contained in an open cavity is investigated in this study. The governing partial differential equations are solved numerically using the Alternate Direct Implicit method together with the Successive Over Relaxation method. The study is focused on studying the flow pattern and the convective and radiative heat transfer rates are studied for different values of radiation parameters namely, the optical thickness of the fluid, scattering albedo, and the Planck number. It was found that in the optically thin limit, an increase in the optical thickness of the fluid raises the temperature and radiation heat transfer of the fluid. However, a further increase in the optical thickness decreases the radiative heat transfer rate due to increase in the energy level of the fluid, which ultimately reduces the total heat transfer rate within the fluid.
Resumo:
Purpose To investigate the effects of a natural oil-based emulsion containing allantoin versus aqueous cream for preventing and managing radiation induced skin reactions (RISR). Methods and Materials A total of 174 patients were randomised and participated in the study. Patients either received Cream 1 (the natural oil-based emulsion containing allantoin) or Cream 2 (aqueous cream). Skin toxicity, pain, itching and skin-related quality of life scores were collected for up to four weeks after radiation treatment. Results Patients who received Cream 1 had a significantly lower average level of Common Toxicity Criteria at week 3 (p<0.05), but had statistically higher average levels of skin toxicity at weeks 7, 8 and 9 (all p<0.001). Similar results were observed when skin toxicity was analysed by grades. With regards to pain, patients in the Cream 2 group had a significantly higher average level of worst pain (p<0.05) and itching (p=0.046) compared to the Cream 1 group at week 3, however these differences were not observed at other weeks. In addition, there was a strong trend for Cream 2 to reduce the incidence of grade 2 or more skin toxicity in comparison to Cream 1 (p=0.056). Overall, more participants in the Cream 1 group were required to use another topical treatment at weeks 8 (p=0.049) and 9 (p=0.01). Conclusion The natural oil-based emulsion containing allantoin appears to have similar effects for managing skin toxicity compared to aqueous cream up to week 5, however, it becomes significantly less effective at later weeks into the radiation treatment and beyond treatment completion (week 6 and beyond). There were no major differences in pain, itching and skin-related quality of life. In light of these results, clinicians and patients can base their decision on costs and preferences. Overall, aqueous cream appears to be a more preferred option.
Resumo:
Radiosensitizing Effect of Electrochemotherapy in a Fractionated Radiation Regimen in Radiosensitive Murine Sarcoma and Radioresistant Adenocarcinoma Tumor Model. Electrochemotherapy can potentiate the radiosensitizing effect of bleomycin, as shown in our previous studies. To bring this treatment closer to use in clinical practice, we evaluated the interaction between electrochemotherapy with bleomycin and single-dose or fractionated radiation in two murine tumor models with different histology and radiosensitivity. Radiosensitive sarcoma SA-1 and radioresistant adenocarcinoma CaNT subcutaneous tumors grown in A/J and CBA mice, respectively, were used. The anti-tumor effect and skin damage around the treated tumors were evaluated after electrochemotherapy with bleomycin alone or combined with single-dose radiation or a fractionated radiation regimen. The anti-tumor effectiveness of electrochemotherapy was more pronounced in SA-1 than CaNT tumors. In both tumor models, the tumor response to radiation was not significantly influenced by bleomycin alone or by electroporation alone. However, electrochemotherapy before the first tumor irradiation potentiated the response to a single-dose or fractionated radiation regimen in both tumors. For the fractionated radiation regimen, normal skin around the treated tumors was damaged fourfold less than for the single-dose regimen. Electrochemotherapy prior to single-dose irradiation induced more damage to the skin around the treated tumors and greater loss of body weight compared to other irradiated groups, whereas electrochemotherapy combined with the fractionated radiation regimen did not. Electrochemotherapy with low doses of bleomycin can also be used safely for radiosensitization of different types of tumors in a fractionated radiation regimen, resulting in a good anti-tumor effect and no major potentiating effect on radiation-induced skin damage. © 2009 by Radiation Research Society.
Resumo:
Background: The present study aimed to evaluate the antitumor effectiveness of systemic interleukin (IL)-12 gene therapy in murine sarcoma models, and to evaluate its interaction with the irradiation of tumors and metastases. To avoid toxic side-effects of IL-12 gene therapy, the objective was to achieve the controlled release of IL-12 after intramuscular gene electrotransfer. Methods: Gene electrotransfer of the plasmid pORF-mIL12 was performed into the tibialis cranialis in A/J and C57BL/6 mice. Systemic release of the IL-12 was monitored in the serum of mice after carrying out two sets of intramuscular IL-12 gene electrotransfer of two different doses of plasmid DNA. The antitumor effectiveness of IL-12 gene electrotransfer alone or in combination with local tumor or lung irradiation with X-rays, was evaluated on subcutaneous SA-1 and LPB tumors, as well as on lung metastases. Results: A synergistic antitumor effect of intramuscular gene electrotransfer combined with local tumor irradiation was observed as a result of the systemic distribution of IL-12. The gene electrotransfer resulted in up to 28% of complete responses of tumors. In combination with local tumor irradiation, the curability was increased by up to 100%. The same effect was observed for lung metastases, where a potentiating factor of 1.3-fold was determined. The amount of circulating IL-12 was controlled by the number of repeats of gene electrotransfer and by the amount of the injected plasmid. Conclusions: The present study demonstrates the feasibility of treatment by IL-12 gene electrotransfer combined with local tumor or lung metastases irradiation on sarcoma tumors for translation into the clinical setting. Copyright © 2009 John Wiley & Sons, Ltd.
Resumo:
Introduction This investigation aimed to assess the consistency and accuracy of radiation therapists (RTs) performing cone beam computed tomography (CBCT) alignment to fiducial markers (FMs) (CBCTFM) and the soft tissue prostate (CBCTST). Methods Six patients receiving prostate radiation therapy underwent daily CBCTs. Manual alignment of CBCTFM and CBCTST was performed by three RTs. Inter-observer agreement was assessed using a modified Bland–Altman analysis for each alignment method. Clinically acceptable 95% limits of agreement with the mean (LoAmean) were defined as ±2.0 mm for CBCTFM and ±3.0 mm for CBCTST. Differences between CBCTST alignment and the observer-averaged CBCTFM (AvCBCTFM) alignment were analysed. Clinically acceptable 95% LoA were defined as ±3.0 mm for the comparison of CBCTST and AvCBCTFM. Results CBCTFM and CBCTST alignments were performed for 185 images. The CBCTFM 95% LoAmean were within ±2.0 mm in all planes. CBCTST 95% LoAmean were within ±3.0 mm in all planes. Comparison of CBCTST with AvCBCTFM resulted in 95% LoA of −4.9 to 2.6, −1.6 to 2.5 and −4.7 to 1.9 mm in the superior–inferior, left–right and anterior–posterior planes, respectively. Conclusions Significant differences were found between soft tissue alignment and the predicted FM position. FMs are useful in reducing inter-observer variability compared with soft tissue alignment. Consideration needs to be given to margin design when using soft tissue matching due to increased inter-observer variability. This study highlights some of the complexities of soft tissue guidance for prostate radiation therapy.
Resumo:
Purpose An emerging developmental tool to help radiation therapists achieve better outcomes is 'peer review'. This review of the current literature summarises the challenges and benefits of peer review in both individual and departmental practice. Discussion There is compelling evidence supporting peer review implementation at both individual and department level in many professions. Implementing peer review requires that radiation therapists and other radiation oncology professionals embrace a culture that supports safety. Peer review can identify trends and barriers associated with quality radiotherapy and share best practice or recommend changes accordingly. Support for peer review must come from pre-registration educational systems as well as clinical managers. Continuing professional development in the workplace is nurtured by peer review of radiotherapy practice and an aptitude for this should be viewed as important to the profession as technical and clinical skills. Conclusion It is clear that peer review has the potential to facilitate reflective practice, improve staff motivation and help foster a culture of quality and safety in radiation oncology. To drive the issues of quality and safety a step further radiation therapists need to accept the challenge of adopting peer review methods in day-to-day practice.
Resumo:
Aim A recent Monte Carlo based study has shown that it is possible to design a diode that measures small field output factors equivalent to that in water. This is accomplished by placing an appropriate sized air gap above the silicon chip (1) with experimental results subsequently confirming that a particular Monte Carlo design was accurate (2). The aim of this work was to test if a new correction-less diode could be designed using an entirely experimental methodology. Method: All measurements were performed on a Varian iX at a depth of 5 cm, SSD of 95 cm and field sizes of 5, 6, 8, 10, 20 and 30 mm. Firstly, the experimental transfer of kq,clin,kq,msr from a commonly used diode detector (IBA, stereotactic field diode (SFD)) to another diode detector (Sun Nuclear, unshielded diode, (EDGEe)) was tested. These results were compared to Monte Carlo calculated values of the EDGEe. Secondly, the air gap above the EDGEe silicon chip was optimised empirically. Nine different air gap “tops” were placed above the EDGEe (air depth = 0.3, 0.6, 0.9 mm; air width = 3.06, 4.59, 6.13 mm). The sensitivity of the EDGEe was plotted as a function of air gap thickness for the field sizes measured. Results: The transfer of kq,clin,kq,msr from the SFD to the EDGEe was correct to within the simulation and measurement uncertainties. The EDGEe detector can be made “correction-less” for field sizes of 5 and 6 mm, but was ∼2% from being “correction-less” at field sizes of 8 and 10 mm. Conclusion Different materials will perturb small fields in different ways. A detector is only “correction-less” if all these perturbations happen to cancel out. Designing a “correction-less” diode is a complicated process, thus it is reasonable to expect that Monte Carlo simulations should play an important role.