121 resultados para Multi-objective simulated annealing
Resumo:
LiFePO4 is a commercially available battery material with good theoretical discharge capacity, excellent cycle life and increased safety compared with competing Li-ion chemistries. It has been the focus of considerable experimental and theoretical scrutiny in the past decade, resulting in LiFePO4 cathodes that perform well at high discharge rates. This scrutiny has raised several questions about the behaviour of LiFePO4 material during charge and discharge. In contrast to many other battery chemistries that intercalate homogeneously, LiFePO4 can phase-separate into highly and lowly lithiated phases, with intercalation proceeding by advancing an interface between these two phases. The main objective of this thesis is to construct mathematical models of LiFePO4 cathodes that can be validated against experimental discharge curves. This is in an attempt to understand some of the multi-scale dynamics of LiFePO4 cathodes that can be difficult to determine experimentally. The first section of this thesis constructs a three-scale mathematical model of LiFePO4 cathodes that uses a simple Stefan problem (which has been used previously in the literature) to describe the assumed phase-change. LiFePO4 crystals have been observed agglomerating in cathodes to form a porous collection of crystals and this morphology motivates the use of three size-scales in the model. The multi-scale model developed validates well against experimental data and this validated model is then used to examine the role of manufacturing parameters (including the agglomerate radius) on battery performance. The remainder of the thesis is concerned with investigating phase-field models as a replacement for the aforementioned Stefan problem. Phase-field models have recently been used in LiFePO4 and are a far more accurate representation of experimentally observed crystal-scale behaviour. They are based around the Cahn-Hilliard-reaction (CHR) IBVP, a fourth-order PDE with electrochemical (flux) boundary conditions that is very stiff and possesses multiple time and space scales. Numerical solutions to the CHR IBVP can be difficult to compute and hence a least-squares based Finite Volume Method (FVM) is developed for discretising both the full CHR IBVP and the more traditional Cahn-Hilliard IBVP. Phase-field models are subject to two main physicality constraints and the numerical scheme presented performs well under these constraints. This least-squares based FVM is then used to simulate the discharge of individual crystals of LiFePO4 in two dimensions. This discharge is subject to isotropic Li+ diffusion, based on experimental evidence that suggests the normally orthotropic transport of Li+ in LiFePO4 may become more isotropic in the presence of lattice defects. Numerical investigation shows that two-dimensional Li+ transport results in crystals that phase-separate, even at very high discharge rates. This is very different from results shown in the literature, where phase-separation in LiFePO4 crystals is suppressed during discharge with orthotropic Li+ transport. Finally, the three-scale cathodic model used at the beginning of the thesis is modified to simulate modern, high-rate LiFePO4 cathodes. High-rate cathodes typically do not contain (large) agglomerates and therefore a two-scale model is developed. The Stefan problem used previously is also replaced with the phase-field models examined in earlier chapters. The results from this model are then compared with experimental data and fit poorly, though a significant parameter regime could not be investigated numerically. Many-particle effects however, are evident in the simulated discharges, which match the conclusions of recent literature. These effects result in crystals that are subject to local currents very different from the discharge rate applied to the cathode, which impacts the phase-separating behaviour of the crystals and raises questions about the validity of using cathodic-scale experimental measurements in order to determine crystal-scale behaviour.
Resumo:
Considerate amount of research has proposed optimization-based approaches employing various vibration parameters for structural damage diagnosis. The damage detection by these methods is in fact a result of updating the analytical structural model in line with the current physical model. The feasibility of these approaches has been proven. But most of the verification has been done on simple structures, such as beams or plates. In the application on a complex structure, like steel truss bridges, a traditional optimization process will cost massive computational resources and lengthy convergence. This study presents a multi-layer genetic algorithm (ML-GA) to overcome the problem. Unlike the tedious convergence process in a conventional damage optimization process, in each layer, the proposed algorithm divides the GA’s population into groups with a less number of damage candidates; then, the converged population in each group evolves as an initial population of the next layer, where the groups merge to larger groups. In a damage detection process featuring ML-GA, as parallel computation can be implemented, the optimization performance and computational efficiency can be enhanced. In order to assess the proposed algorithm, the modal strain energy correlation (MSEC) has been considered as the objective function. Several damage scenarios of a complex steel truss bridge’s finite element model have been employed to evaluate the effectiveness and performance of ML-GA, against a conventional GA. In both single- and multiple damage scenarios, the analytical and experimental study shows that the MSEC index has achieved excellent damage indication and efficiency using the proposed ML-GA, whereas the conventional GA only converges at a local solution.
Resumo:
Needs assessment strategies can facilitate prioritisation of resources. To develop a needs assessment tool for use with advanced cancer patients and caregivers, to prompt early intervation. A convenience sample of 103 health professionals viewed three videotaped consultations involving a simulated patient, his/her caregiver and a health professional, completed the Palliative Care Needs Assessment Tool (PC-NAT) and provided feedback on clarity, content and acceptability of the PC-NAT. Face and content validity, acceptability and feasibility of the PC-NAT were confirmed. Kappa scores indicated adequate inter-rater reliability for the majority of domains; the patient spirituality domain and the caregiver physical and family and relationship domains had low reliability. The PC-NAT can be used by health professionals with a range of clinical expertise to identify individuals' needs, thereby enabling early intervention. Further psychometric testing and an evaluation to assess the impact of the systematic use of the PC-NAT on quality of life, unmet needs and service utilisation of patients and caregivers are underway.
Resumo:
High-speed broadband internet access is widely recognised as a catalyst to social and economic development. However, the provision of broadband Internet services with the existing solutions to rural population, scattered over an extensive geographical area, remains both an economic and technical challenge. As a feasible solution, the Commonwealth Scientific and Industrial Research Organization (CSIRO) proposed a highly spectrally efficient, innovative and cost-effective fixed wireless broadband access technology, which uses analogue TV frequency spectrum and Multi-User MIMO (MUMIMO) technology with Orthogonal-Frequency-Division-Multiplexing (OFDM). MIMO systems have emerged as a promising solution for the increasing demand of higher data rates, better quality of service, and higher network capacity. However, the performance of MIMO systems can be significantly affected by different types of propagation environments e.g., indoor, outdoor urban, or outdoor rural and operating frequencies. For instance, large spectral efficiencies associated with MIMO systems, which assume a rich scattering environment in urban environments, may not be valid for all propagation environments, such as outdoor rural environments, due to the presence of less scatterer densities. Since this is the first time a MU-MIMO-OFDM fixed broadband wireless access solution is deployed in a rural environment, questions from both theoretical and practical standpoints arise; For example, what capacity gains are available for the proposed solution under realistic rural propagation conditions?. Currently, no comprehensive channel measurement and capacity analysis results are available for MU-MIMO-OFDM fixed broadband wireless access systems which employ large scale multiple antennas at the Access Point (AP) and analogue TV frequency spectrum in rural environments. Moreover, according to the literature, no deterministic MU-MIMO channel models exist that define rural wireless channels by accounting for terrain effects. This thesis fills the aforementioned knowledge gaps with channel measurements, channel modeling and comprehensive capacity analysis for MU-MIMO-OFDM fixed wireless broadband access systems in rural environments. For the first time, channel measurements were conducted in a rural farmland near Smithton, Tasmania using CSIRO's broadband wireless access solution. A novel deterministic MU-MIMO-OFDM channel model, which can be used for accurate performance prediction of rural MUMIMO channels with dominant Line-of-Sight (LoS) paths, was developed under this research. Results show that the proposed solution can achieve 43.7 bits/s/Hz at a Signal-to- Noise Ratio (SNR) of 20 dB in rural environments. Based on channel measurement results, this thesis verifies that the deterministic channel model accurately predicts channel capacity in rural environments with a Root Mean Square (RMS) error of 0.18 bits/s/Hz. Moreover, this study presents a comprehensive capacity analysis of rural MU-MIMOOFDM channels using experimental, simulated and theoretical models. Based on the validated deterministic model, further investigations on channel capacity and the eects of capacity variation, with different user distribution angles (θ) around the AP, were analysed. For instance, when SNR = 20dB, the capacity increases from 15.5 bits/s/Hz to 43.7 bits/s/Hz as θ increases from 10° to 360°. Strategies to mitigate these capacity degradation effects are also presented by employing a suitable user grouping method. Outcomes of this thesis have already been used by CSIRO scientists to determine optimum user distribution angles around the AP, and are of great significance for researchers and MU-MUMO-OFDM system developers to understand the advantages and potential capacity gains of MU-MIMO systems in rural environments. Also, results of this study are useful to further improve the performance of MU-MIMO-OFDM systems in rural environments. Ultimately, this knowledge contribution will be useful in delivering efficient, cost-effective high-speed wireless broadband systems that are tailor-made for rural environments, thus, improving the quality of life and economic prosperity of rural populations.
Resumo:
Police in-vehicle systems include a visual output mobile data terminal (MDT) with manual input via touch screen and keyboard. This study investigated the potential for voice-based input and output modalities for reducing subjective workload of police officers while driving. Nineteen experienced drivers of police vehicles (one female) from New South Wales (NSW) Police completed four simulated urban drives. Three drives included a concurrent secondary task: an imitation licence number search using an emulated MDT. Three different interface output-input modalities were examined: Visual-Manual, Visual-Voice, and Audio-Voice. Following each drive, participants rated their subjective workload using the NASA - Raw Task Load Index and completed questions on acceptability. A questionnaire on interface preferences was completed by participants at the end of their session. Engaging in secondary tasks while driving significantly increased subjective workload. The Visual-Manual interface resulted in higher time demand than either of the voice-based interfaces and greater physical demand than the Audio-Voice interface. The Visual-Voice and Audio-Voice interfaces were rated easier to use and more useful than the Visual-Manual interface, although not significantly different from each other. Findings largely echoed those deriving from the analysis of the objective driving performance data. It is acknowledged that under standard procedures, officers should not drive while performing tasks concurrently with certain invehicle policing systems; however, in practice this sometimes occurs. Taking action now to develop voice-based technology for police in-vehicle systems has potential to realise visions for potentially safer and more efficient vehicle-based police work.
Resumo:
The European Early Lung Cancer (EUELC) project aims to determine if specific genetic alterations occurring in lung carcinogenesis are detectable in the respiratory epithelium. In order to pursue this objective, nonsmall cell lung cancer (NSCLC) patients with a very high risk of developing progressive lung cancer were recruited from 12 centres in eight European countries: France, Germany, southern Ireland, Italy, the Netherlands, Poland, Spain and the UK. In addition, NSCLC patients were followed up every 6 months for 36 months. A European Bronchial Tissue Bank was set up at the University of Liverpool (Liverpool, UK) to optimise the use of biological specimens. The molecular - pathological investigations were subdivided into specific work packages that were delivered by EUELC Partners. The work packages encompassed mutational analysis, genetic instability, methylation profiling, expression profiling utilising immunohistochemistry and chip-based technologies, as well as in-depth analysis of FHIT and RARβ genes, the telomerase catalytic subunit hTERT and genotyping of susceptibility genes in specific pathways. The EUELC project engendered a tremendous collaborative effort, and it enabled the EUELC Partners to establish protocols for assessing molecular biomarkers in early lung cancer with the view to using such biomarkers for early diagnosis and as intermediate end-points in future chemopreventive programmes. Copyright©ERS Journals Ltd 2009.
Resumo:
Spectrum sensing of multiple primary user channels is a crucial function in cognitive radio networks. In this paper we propose an optimal, sensing resource allocation algorithm for multi-channel cooperative spectrum sensing. The channel target is implemented as an objective and constraint to ensure a pre-determined number of empty channels are detected for secondary user network operations. Based on primary user traffic parameters, we calculate the minimum number of primary user channels that must be sensed to satisfy the channel target. We implement a hybrid sensing structure by grouping secondary user nodes into clusters and assign each cluster to sense a different primary user channels. We then solve the resource allocation problem to find the optimal sensing configuration and node allocation to minimise sensing duration. Simulation results show that the proposed algorithm requires the shortest sensing duration to achieve the channel target compared to existing studies that require long sensing and cannot guarantee the target.
Resumo:
Accurate and detailed measurement of an individual's physical activity is a key requirement for helping researchers understand the relationship between physical activity and health. Accelerometers have become the method of choice for measuring physical activity due to their small size, low cost, convenience and their ability to provide objective information about physical activity. However, interpreting accelerometer data once it has been collected can be challenging. In this work, we applied machine learning algorithms to the task of physical activity recognition from triaxial accelerometer data. We employed a simple but effective approach of dividing the accelerometer data into short non-overlapping windows, converting each window into a feature vector, and treating each feature vector as an i.i.d training instance for a supervised learning algorithm. In addition, we improved on this simple approach with a multi-scale ensemble method that did not need to commit to a single window size and was able to leverage the fact that physical activities produced time series with repetitive patterns and discriminative features for physical activity occurred at different temporal scales.
Resumo:
A better understanding of the behaviour of prepared cane and bagasse, and the ability to model the mechanical behaviour of bagasse as it is squeezed in a milling unit to extract juice, would help identify how to improve the current process. There are opportunities to decrease bagasse moisture from a milling unit. The behaviour of bagasse in chutes is poorly understood. Previous investigations have shown that juice flow through bagasse obeys Darcy’s permeability law, that the grip of the rough surface of the grooves on the bagasse can be represented by the Mohr-Coulomb failure criterion for soils, and that the internal mechanical behaviour of the bagasse is critical state behaviour similar to that for sand and clay. Progress has been made in the last 11 years towards implementing a mechanical model for bagasse in finite element software. The objective is to be able to correctly simulate various simple mechanical loading conditions measured in the laboratory. Combining these behaviours together is thought to have a high probability of reproducing the complicated stress conditions in a milling unit. This paper reports on progress made towards modelling the fifth and final (and most challenging) of the simple loading conditions: the shearing of heavily over-consolidated bagasse, using a specific model for bagasse in a multi-element simulation.
Resumo:
Studies examining the ability of motivational enhancement therapy (MET) to augment education provision among ecstasy users have produced mixed results and none have examined whether treatment fidelity was related to ecstasy use outcomes. The primary objectives of this multi-site, parallel, two-group randomized controlled trial were to determine if a single-session of MET could instill greater commitment to change and reduce ecstasy use and related problems more so than an education-only intervention and whether MET sessions delivered with higher treatment fidelity are associated with better outcomes. The secondary objective was to assess participants’ satisfaction with their assigned interventions. Participants (N = 174; Mage = 23.62) at two Australian universities were allocated randomly to receive a 15-minute educational session on ecstasy use (n = 85) or a 50-minute session of MET that included an educational component (n = 89). Primary outcomes were assessed at baseline, and then at 4-, 16-, and 24-weeks post-baseline, while the secondary outcome measure was assessed 4-weeks post-baseline by researchers blind to treatment allocation. Overall, the treatment fidelity was acceptable to good in the MET condition. There were no statistical differences at follow-up between the groups on the primary outcomes of ecstasy use, ecstasy-related problems, and commitment to change. Both interventions groups reported a 50% reduction in their ecstasy use and a 20% reduction in the severity of their ecstasy-related problems at the 24-week follow up. Commitment to change slightly improved for both groups (9% - 17%). Despite the lack of between-group statistical differences on primary outcomes, participants who received a single session of MET were slightly more satisfied with their intervention than those who received education only. MI fidelity was not associated with ecstasy use outcomes. Given these findings, future research should focus on examining mechanisms of change. Such work may suggest new methods for enhancing outcomes.
Resumo:
This report presents learnings, case studies, guidelines and resources for non-government organisations that are planning to implement shared or collaborative arrangements with other agencies. It summarises results from an evaluation of the implementation phase of the Multi-Tenant Service Centre (MTSC) Pilots Project, which was completed in June 2008. This evaluation shows that developing and implementing shared and collaborative arrangements is a complex process that presents many risks, challenges and barriers to success, but can have many potential benefits for non government organisations. As this report makes clear, there is no ‘one size fits all’ approach to this process. The MTSC Pilots Project was conducted by the Department of Communities (DoC), Queensland Government, as part of its Strengthening Non-Government Organisations strategy. The objective of the MTSC Pilots initiative was to co-locate separate service providers in an appropriately located centre, operating with effective and transparent management, which enabled service providers to improve client services. Three MTSC consortiums in Mackay, Caboolture and Toowoomba were selected as the pilots over a four year period from 2006 – 2010.
Resumo:
High-angular resolution diffusion imaging (HARDI) can reconstruct fiber pathways in the brain with extraordinary detail, identifying anatomical features and connections not seen with conventional MRI. HARDI overcomes several limitations of standard diffusion tensor imaging, which fails to model diffusion correctly in regions where fibers cross or mix. As HARDI can accurately resolve sharp signal peaks in angular space where fibers cross, we studied how many gradients are required in practice to compute accurate orientation density functions, to better understand the tradeoff between longer scanning times and more angular precision. We computed orientation density functions analytically from tensor distribution functions (TDFs) which model the HARDI signal at each point as a unit-mass probability density on the 6D manifold of symmetric positive definite tensors. In simulated two-fiber systems with varying Rician noise, we assessed how many diffusionsensitized gradients were sufficient to (1) accurately resolve the diffusion profile, and (2) measure the exponential isotropy (EI), a TDF-derived measure of fiber integrity that exploits the full multidirectional HARDI signal. At lower SNR, the reconstruction accuracy, measured using the Kullback-Leibler divergence, rapidly increased with additional gradients, and EI estimation accuracy plateaued at around 70 gradients.
Resumo:
This paper proposes a new multi-resource multi-stage mine production timetabling problem for optimising the open-pit drilling, blasting and excavating operations under equipment capacity constraints. The flow process is analysed based on the real-life data from an Australian iron ore mine site. The objective of the model is to maximise the throughput and minimise the total idle times of equipment at each stage. The following comprehensive mining attributes and constraints are considered: types of equipment; operating capacities of equipment; ready times of equipment; speeds of equipment; block-sequence-dependent movement times; equipment-assignment-dependent operational times; etc. The model also provides the availability and usage of equipment units at multiple operational stages such as drilling, blasting and excavating stages. The problem is formulated by mixed integer programming and solved by ILOG-CPLEX optimiser. The proposed model is validated with extensive computational experiments to improve mine production efficiency at the operational level.
Resumo:
Objective To develop a child victimization survey among a diverse group of child protection experts and examine the performance of the instrument through a set of international pilot studies. Methods The initial draft of the instrument was developed after input from scientists and practitioners representing 40 countries. Volunteers from the larger group of scientists participating in the Delphi review of the ICAST P and R reviewed the ICAST C by email in 2 rounds resulting in a final instrument. The ICAST C was then translated and back translated into six languages and field tested in four countries using a convenience sample of 571 children 12–17 years of age selected from schools and classrooms to which the investigators had easy access. Results The final ICAST C Home has 38 items and the ICAST C Institution has 44 items. These items serve as screeners and positive endorsements are followed by queries for frequency and perpetrator. Half of respondents were boys (49%). Endorsement for various forms of victimization ranged from 0 to 51%. Many children report violence exposure (51%), physical victimization (55%), psychological victimization (66%), sexual victimization (18%), and neglect in their homes (37%) in the last year. High rates of physical victimization (57%), psychological victimization (59%), and sexual victimization (22%) were also reported in schools in the last year. Internal consistency was moderate to high (alpha between .685 and .855) and missing data low (less than 1.5% for all but one item). Conclusions In pilot testing, the ICAST C identifies high rates of child victimization in all domains. Rates of missing data are low, and internal consistency is moderate to high. Pilot testing demonstrated the feasibility of using child self-report as one strategy to assess child victimization. Practice implications The ICAST C is a multi-national, multi-lingual, consensus-based survey instrument. It is available in six languages for international research to estimate child victimization. Assessing the prevalence of child victimization is critical in understanding the scope of the problem, setting national and local priorities, and garnering support for program and policy development aimed at child protection.
Resumo:
The primary objective of this paper is to study the use of medical image-based finite element (FE) modelling in subjectspecific midsole design and optimisation for heel pressure reduction using a midsole plug under the calcaneus area (UCA). Plugs with different relative dimensions to the size of the calcaneus of the subject have been incorporated in the heel region of the midsole. The FE foot model was validated by comparing the numerically predicted plantar pressure with biomechanical tests conducted on the same subject. For each UCA midsole plug design, the effect of material properties and plug thicknesses on the plantar pressure distribution and peak pressure level during the heel strike phase of normal walking was systematically studied. The results showed that the UCA midsole insert could effectively modify the pressure distribution, and its effect is directly associated with the ratio of the plug dimension to the size of the calcaneus bone of the subject. A medium hardness plug with a size of 95% of the calcaneus has achieved the best performance for relieving the peak pressure in comparison with the pressure level for a solid midsole without a plug, whereas a smaller plug with a size of 65% of the calcaneus insert with a very soft material showed minimum beneficial effect for the pressure relief.